N,S co-doped carbon dots based fluorescent “on-off-on” sensor for determination of ascorbic acid in common fruits
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
A switchable sensor based on N and S co-doped carbon dots (N,S-CDs) was developed to determine ascorbic acid (AA) content in common fruits via fluorescence quenching of N,S-CDs by Fe3+ (off) and recovery by AA (on). TEM showed that the particle size was 2.35-7.95 nm with an average diameter of 5.12 nm. XPS and FTIR confirmed the presence of -OH, -COOH and -NH2 on N,S-CDs surface. UV-vis and FTIR revealed that the coordination of -COOH and -NH2 on N,S-CDs surface with Fe3+ accounted for FL quenching, and the release of -NH2 from coordination complexes due to the reduction of Fe3+ by AA led to partly FL recovery. The sensor allowed detecting AA in the linear range of 10-200 μmol/L with a LOD of 4.69 μmol/L. AA contents in common fruits detected by the sensor were in good agreement with the reference method (P > 0.05), indicating a practical fluorescent sensor for AA detection in common fruits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon quantum dots and their applications
Lim, S. Y., Shen, W., & Gao, Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00269e · Cited by 4,976
Chen, Q., Espey, M. G., Sun, A. Y., Pooput, C., Kirk, K. L., Krishna, M. C., Khosh, D. B., Drisko, J., & Levine, M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804226105 · Cited by 854
Zheng, M., Xie, Z., Qu, D., Li, D., Du, P., Jing, X., & Sun, Z. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4042355 · Cited by 794
New approaches in improving the shelf life of minimally processed fruit and vegetables
Ahvenainen, R. (1996) · Trends in Food Science & Technology · doi:10.1016/0924-2244(96)10022-4 · Cited by 571
Metal-Free Carbon Nanomaterials Become More Active than Metal Catalysts and Last Longer
Yu, D., Nagelli, E., Du, F., & Dai, L. (2010) · The Journal of Physical Chemistry Letters · doi:10.1021/jz100533t · Cited by 563
Guo, Y., Wang, Z., Shao, H., & Jiang, X. (2013) · Carbon · doi:10.1016/j.carbon.2012.10.028 · Cited by 546
Tang, D., Liu, J., Wu, X., Liu, R., Han, X., Han, Y., Huang, H., Liu, Y., & Kang, Z. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501256x · Cited by 484
Self-citationMiao, X., Yan, X., Qu, D., Li, D., Tao, F. F., & Sun, Z. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b04514 · Cited by 472
Qian, Z., Shan, X., Chai, L., Ma, J., Chen, J., & Feng, H. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am500403n · Cited by 382
Facile synthesis of nitrogen-doped carbon dots for Fe3+ sensing and cellular imaging
Gong, X., Lu, W., Paau, M. C., Hu, Q., Wu, X., Shuang, S., Dong, C., & Choi, M. M. F. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.12.045 · Cited by 327
Non-spectrophotometric methods for the determination of Vitamin C
Arya, S. P., Mahajan, M., & Jain, P. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)00909-0 · Cited by 253
Gong, X., Liu, Y., Yang, Z., Shuang, S., Zhang, Z., & Dong, C. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.02.038 · Cited by 239
Ye, Q., Yan, F., Luo, Y., Wang, Y., Zhou, X., & Chen, L. (2017) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2016.10.039 · Cited by 203
Gökmen, V., Kahraman, N., Demir, N., & Acar, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00080-7 · Cited by 184
Analytical strategies to evaluate antioxidants in food: a review
André, C., Castanheira, I., Cruz, J. M., Paseiro, P., & Sanches-Silva, A. (2010) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2009.12.003 · Cited by 183
Chen, J., Liu, J., Li, J., Xu, L., & Qiao, Y. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2016.09.040 · Cited by 168
Wang, H., Lu, Q., Hou, Y., Liu, Y., & Zhang, Y. (2016) · Talanta · doi:10.1016/j.talanta.2016.04.020 · Cited by 152
GUCLU, K., Başkan, K. S., Tütem, E., Özyürek, M., & Apak, R. (2004) · Talanta · doi:10.1016/j.talanta.2004.08.048 · Cited by 147
Hou, J., Dong, G., Tian, Z., Lu, J., Wang, Q., Ai, S., & Wang, M. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.11.134 · Cited by 98
Yang, P., Zhao, J., Zhang, L., Li, L., & Zhu, Z. (2015) · Chemistry - A European Journal · doi:10.1002/chem.201405088 · Cited by 95
Total ascorbic acid determination in fresh squeezed orange juice by gas chromatography
Silva, F. O. (2004) · Food Control · doi:10.1016/j.foodcont.2003.11.007 · Cited by 90
Tang, Y., & Wu, M. (2004) · Talanta · doi:10.1016/j.talanta.2004.08.013 · Cited by 79
Cited by
Mansuriya, B. D., & Altintas, Z. (2021) · Nanomaterials · doi:10.3390/nano11102525 · Cited by 438
Advances and perspectives in carbon dot-based fluorescent probes: Mechanism, and application
Li, X., Zhao, S., Li, B., Yang, K., Lan, M., & Zeng, L. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213686 · Cited by 372
A review: recent advances in preparations and applications of heteroatom-doped carbon quantum dots
Kou, X., Jiang, S., Park, S.-J., & Meng, L.-Y. (2020) · Dalton Transactions · doi:10.1039/d0dt01004a · Cited by 315
Wang, C., Shi, H., Yang, M., Yan, Y., Liu, E., Ji, Z., & Fan, J. (2020) · Materials Research Bulletin · doi:10.1016/j.materresbull.2019.110730 · Cited by 257
Yadav, P. K., Singh, V. K., Chandra, S., Bano, D., Kumar, V., Talat, M., & Hasan, S. H. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b01528 · Cited by 240
Metadata
- Authors
- Luo, X., Zhang, W., Han, Y., Chen, X., Zhu, L., Tang, W., Wang, J., Yue, T., & Li, Z.
- Venue
- Food Chemistry
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 258
- Pages
- 214-221
- ISSN
- 0308-8146 (ISSN-L)
- OpenAlex
- W2793236702
- Cited by
- 273
- References
- 22
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.