Deep eutectic mixture membrane-based microextraction: HPLC-FLD determination of phenols in smoked food samples
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A novel approach for effective sample pretreatment of food was developed. This approach was based on in situ deep eutectic mixtures formation between analytes (hydrogen bond donors) and choline chloride (a hydrogen bond acceptor) supported in a hydrophilic porous membrane. By this action, the analytes were extracted and retained into the hydrophilic porous membrane. Finally, the hydrophilic porous membrane containing the analytes was transferred into an aqueous phase and back-extraction occurred due to deep eutectic mixture decomposition in the aqueous phase. The developed approach was applied to the HPLC-FLD determination of phenols (phenol, o-cresol, p-cresol, eugenol, isoeugenol and guaiacol) in smoked food samples. The limits of detection, calculated from a blank test based on 3σ, were 0.3 µg kg-1 for phenol, o-cresol, p-cresol; 0.6 µg kg-1 for eugenol, isoeugenol; and 1 µg kg-1 for guaiacol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Application of deep eutectic solvents in analytical chemistry. A review
Shishov, A., Bulatov, A., Locatelli, M., Carradori, S., & Andruch, V. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.07.015 · Cited by 617
Self-citationAydin, F., Yilmaz, E., & Soylak, M. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.02.014 · Cited by 165
In situ decomposition of deep eutectic solvent as a novel approach in liquid-liquid microextraction
Shishov, A., Chromá, R., Vakh, C., Kuchár, J., Simon, A., Andruch, V., & Bulatov, A. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.03.038 · Cited by 97
Self-citationShishov, A., Volodina, N., Nechaeva, D., Gagarinova, S., & Bulatov, A. (2018) · RSC Advances · doi:10.1039/c8ra07300g · Cited by 63
Self-citation
Cited by
Deep eutectic solvents are not only effective extractants
Shishov, A., Pochivalov, A., Nugbienyo, L., Andruch, V., & Bulatov, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115956 · Cited by 278
Self-citationSustainable green solvents for microextraction techniques: Recent developments and applications
Carasek, E., Bernardi, G., Morelli, D., & Merib, J. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461944 · Cited by 99
Shishov, A., Gerasimov, A., Nechaeva, D., Volodina, N., Bessonova, E., & Bulatov, A. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104837 · Cited by 69
Self-citationLi, M., Liu, Y., Hu, F., Ren, H., & Duan, E. (2021) · Processes · doi:10.3390/pr9101716 · Cited by 45
“[26] developed in situ deep eutectic mixtures supported in a hydrophilic porous membrane.”
Background
Metadata
- Authors
- Shishov, A., Gagarionova, S., & Bulatov, A.
- Venue
- Food Chemistry
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 314
- Pages
- 126097
- ISSN
- 0308-8146 (ISSN-L)
- OpenAlex
- W2997298778
- Cited by
- 49
- References
- 4
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep eutectic mixture membrane-based microextraction: HPLC-FLD determination of phenols in smoked food samples. https://app.cochat.ai/papers/10.1016/j.foodchem.2019.126097
- The paper
- Shishov, A., Gagarionova, S., & Bulatov, A. (2020). Deep eutectic mixture membrane-based microextraction: HPLC-FLD determination of phenols in smoked food samples. Food Chemistry. https://doi.org/10.1016/j.foodchem.2019.126097
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.