The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Experimental design of ligandless sonication-assisted liquid-phases microextraction based on hydrophobic deep eutectic solvents for accurate determination of Pb(II) and Cd(II) from waters and food samples at trace levels
Abstract
A straightforward, accurate and efficient analytical procedure was developed by ligandless sonication-assisted liquid- phases microextraction based on hydrophobic deep eutectic solvents (SA-LPME-HDES) to trace toxic Pb(II) and Cd(II) in waters and foods. Optimization of the SA-LPME-HDES procedure was carried out by Box-Behnken design. Under optimum conditions, linear ranges for Pb(II) and Cd(II) were 0.8-350 (r2:0.9962) and 1.5-500 µg L-1 (r2: 0.9937), respectively. Relative standard deviations (N = 5, 10 µg L-1) were 1.4% for Pb(II) and 1.6% for Cd(II), respectively. Limits of detection were 0.24, and 0.46 µg L-1, respectively. The accuracy was evaluated by the analysis of two certified reference materials and the results were to be in agreement with the certified values. The SA-LPME-HDES method was successfully applied to tap water, mineral water, river water, well-water, sesame, peanut, eggplant, corn, wheat, soy and cucumber. The SA-LPME-HDES method allows operational simplicity, green, and low cost when compared with some microextraction procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Heavy metals are among the most widespread soil and environmental pollutants (Zwolak et al., 2019; Elik et al., 2022; Zhang et al., 2022)”
From Effect of gamma irradiation on the uptake, translocation, and phytotoxicity of lead and cadmium in a soil–barley (Hordeum vulgare L.) system (2025) · cites this paper as Elik et al., 2022
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrophobic deep eutectic solvents in microextraction techniques–A review
Makoś, P., Słupek, E., & Gębicki, J. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104384 · Cited by 469
Microextraction Techniques with Deep Eutectic Solvents
Plastiras, O.-E., Andreasidou, E., & Samanidou, V. (2020) · Molecules · doi:10.3390/molecules25246026 · Cited by 84
Taşpınar, H., Elik, A., Kaya, S., & Altunay, N. (2021) · Food Chemistry · doi:10.1016/j.foodchem.2021.129817 · Cited by 49
Self-citation
Research works printed but not linked: 23
- Altunay, 2019, Food Chemistry, 293, 378, 10.1016/j.foodchem.2019.05.019 · DOI
- Altunay, 2021, A new analytical approach for preconcentration, separation and determination of Pb (II) and Cd (II) in real samples using a new adsorbent: Synthesis, characterization and application, Food Chemistry, 359, 129923, 10.1016/j.foodchem.2021.129923 · DOI
- Chen, 2019, Dispersive micro-solid phase extraction using magnetic ZnFe2O4 nanotubes as adsorbent for preconcentration of Co (II), Ni (II), Mn (II) and Cd (II) followed by ICP-MS determination, Microchemical Journal, 147, 232, 10.1016/j.microc.2019.02.066 · DOI
- Faraji, 2019, Determination of some red dyes in food samples using a hydrophobic deep eutectic solvent-based vortex assisted dispersive liquid-liquid microextraction coupled with high performance liquid chromatography, Journal of Chromatography A, 1591, 15, 10.1016/j.chroma.2019.01.022 · DOI · Paper page
- Greenberg, 2011, Neutron activation analysis: A primary method of measurement, Spectrochimica Acta Part B: Atomic Spectroscopy, 66, 193, 10.1016/j.sab.2010.12.011 · doi:10.1016/j.sab.2010.12.011
- Hafez, 2020, Ultrasound-Assisted Ionic Liquid Microextraction for Preconcentration of Cadmium in Water, Vegetables and Hair Samples Prior to FAAS Determination, Current Analytical Chemistry, 16, 1022, 10.2174/1573411015666191205104244 · DOI
- Kasa, 2019, Determination of cadmium at trace levels in parsley samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with cloud point extraction, Measurement, 147, 106841, 10.1016/j.measurement.2019.07.069 · doi:10.1016/j.measurement.2019.07.069
- Koosha, 2020, A microextraction method based on precipitation for the simultaneous separation and preconcentration of cadmium and lead before their determination by FAAS: Experimental design methodology, Separation Science and Technology, 1
- Li, 2018, Thiol-rich polyhedral oligomeric silsesquioxane-modified magnetic nanoparticles for the highly efficient separation and preconcentration of Cd (II) and Pb (II) in food and water prior to ICP-OES determination, Journal of Analytical Atomic Spectrometry, 33, 1974, 10.1039/C8JA00223A · doi:10.1039/c8ja00223a
- Maleki, 2019, Polyamidoamine dendrimer functionalized iron oxide nanoparticles for simultaneous electrochemical detection of Pb2+ and Cd2+ ions in environmental waters, Measurement, 140, 81, 10.1016/j.measurement.2019.03.052 · doi:10.1016/j.measurement.2019.03.052
- Meira, 2019, Combination of extraction induced by microemulsion-breaking and pre-concentration using magnetic nanoparticles for multi-element determination of Cd, Cr, Cu and Pb in gasoline samples using energy dispersive X-ray fluorescence spectrometry, Microchemical Journal, 147, 660, 10.1016/j.microc.2019.03.068 · DOI
- Miró, 2012, Recent advances and future prospects of mesofluidic Lab-on-a-Valve platforms in analytical sciences–A critical review, Analytica chimica acta, 750, 3, 10.1016/j.aca.2012.03.049 · DOI
- Osowska, 2019, New potentials in the extraction of trace metal using natural deep eutectic solvents (NADES), Food Analytical Methods, 12, 926, 10.1007/s12161-018-01426-y · DOI
- Safavi, 2018, Vortex-assisted liquid-liquid microextraction based on hydrophobic deep eutectic solvent for determination of malondialdehyde and formaldehyde by HPLC-UV approach, Microchemical Journal, 143, 166, 10.1016/j.microc.2018.07.036 · DOI · Paper page
- Saleem, 2018, Impact of lead tolerant plant growth promoting rhizobacteria on growth, physiology, antioxidant activities, yield and lead content in sunflower in lead contaminated soil, Chemosphere, 195, 606, 10.1016/j.chemosphere.2017.12.117 · DOI
- Sarwar, 2010, Role of mineral nutrition in minimizing cadmium accumulation by plants, Journal of the Science of Food and Agriculture, 90, 925, 10.1002/jsfa.3916 · DOI · Paper page
- Şaylan, 2020, Determination of trace nickel in chamomile tea and coffee samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with dispersive liquid-liquid microextraction method using a Schiff base ligand, Journal of Food Composition and Analysis, 88, 103454, 10.1016/j.jfca.2020.103454 · DOI
- Stalikas, 2009, Developments on chemometric approaches to optimize and evaluate microextraction, Journal of Chromatography A, 1216, 175, 10.1016/j.chroma.2008.11.060 · DOI · Paper page
- Tchounwou, 2012, Heavy metal toxicity and the environment, Molecular, Clinical and Environmental Toxicology, 133, 10.1007/978-3-7643-8340-4_6 · DOI · Paper page
- Tuzen, 2020, Poly (styrene)-co-2-vinylpyridine copolymer as a novel solid-phase adsorbent for determination of manganese and zinc in foods and vegetables by FAAS, Food Chemistry, 333, 127504, 10.1016/j.foodchem.2020.127504 · DOI · Paper page
- Werner, 2018, Ionic liquid ultrasound-assisted dispersive liquid-liquid microextraction based on solidification of the aqueous phase for preconcentration of heavy metals ions prior to determination by LC-UV, Talanta, 182, 69, 10.1016/j.talanta.2018.01.060 · DOI
- Yang, 2004, Cadmium tolerance and hyperaccumulation in a new Zn-hyperaccumulating plant species (Sedum alfredii Hance), Plant and soil, 259, 181, 10.1023/B:PLSO.0000020956.24027.f2 · DOI · Paper page
- Zwolak, 2019, Sources of soil pollution by heavy metals and their accumulation in vegetables: A review, Water, Air, & Soil Pollution, 230, 1, 10.1007/s11270-019-4221-y · DOI · Paper page
Cited by
Sportiello, L., Favati, F., Condelli, N., Di Cairano, M., Caruso, M. C., Simonato, B., Tolve, R., & Galgano, F. (2023) · Food Chemistry · doi:10.1016/j.foodchem.2022.134703 · Cited by 87
Samanpong, N., Wongsaipun, S., Udnan, Y., Sirikulkajorn, A., Masawat, P., & Chaiyasith, W. C. (2024) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2024.106753 · Cited by 15
Application of Deep Eutectic Solvents for the Determination of Inorganic Analytes
Andruch, V., Vojteková, V., Kalyniukova, A., Zengin, G., Hagarová, I., & Yordanova, T. (2025) · Advances in Sample Preparation · doi:10.1016/j.sampre.2025.100158 · Cited by 14
Karibayev, M., Tugelbay, S., Amankeldiyeva, A., Akilbekov, B., Ibrayem, T., Zhengis, A., Shah, D., Nurgalieva, D., & Baisalova, G. (2026) · Talanta · doi:10.1016/j.talanta.2026.129800 · Cited by 9
Bişgin, A. T., Elik, A., & Altunay, N. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.114790 · Cited by 9
Self-citation
Metadata
- Authors
- Elik, A., Demirbaş, A., & Altunay, N.
- Venue
- Food Chemistry
- Publisher
- Elsevier BV
- Published
- 2022-03
- Volume
- 371
- Pages
- 131138
- ISSN
- 0308-8146
- Cited by
- 52
- References
- 3
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental design of ligandless sonication-assisted liquid-phases microextraction based on hydrophobic deep eutectic solvents for accurate determination of Pb(II) and Cd(II) from waters and food samples at trace levels. https://app.cochat.ai/papers/10.1016/j.foodchem.2021.131138
- The paper
- Elik, A., Demirbaş, A., & Altunay, N. (2022). Experimental design of ligandless sonication-assisted liquid-phases microextraction based on hydrophobic deep eutectic solvents for accurate determination of Pb(II) and Cd(II) from waters and food samples at trace levels. Food Chemistry. https://doi.org/10.1016/j.foodchem.2021.131138
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.