Decreased sensitivity associated with an altered formulation of a commercially available kit for detection of protein carbonyls
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Carbonylation is a commonly studied form of oxidative modification to proteins which can be conveniently detected using commercially available kits. The most common of these kits is the Oxyblot™ Protein Oxidation Detection Kit (Chemicon/Millipore). Over the past year we have observed severely diminished sensitivity of these kits which was shown to be a result of a change in the formulation of one of the components supplied in the kit. This component, the 10X 2,4-dinitrophenylhydrazine derivatization solution, which had previously been dissolved in 100% trifluoroacetic acid (TFA), was now dissolved in 2N hydrochloric acid, which according to our results is not acid enough. Further, we observed that upon storage even DNPH dissolved in TFA is subject to degradation. Based on these studies, we make recomendations that should improve the sensitivity and reproducibilty of this assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidation of Methionine Residues of Proteins: Biological Consequences
Stadtman, E. R., Moskovitz, J., & Levine, R. L. (2003) · Antioxidants & Redox Signaling · doi:10.1089/152308603770310239 · Cited by 344
Cited by
Jung, J. E., Kim, G. S., & Chan, P. H. (2011) · Stroke · doi:10.1161/strokeaha.111.626648 · Cited by 127
Jang, S., Lewis, T. S., Powers, C., Khuchua, Z., Baines, C. P., Wipf, P., & Javadov, S. (2017) · Antioxidants & Redox Signaling · doi:10.1089/ars.2016.6635 · Cited by 103
Analysis of protein carbonylation — pitfalls and promise in commonly used methods
Rogowska-Wrzesinska, A., Wojdyla, K., Nedić, O., Baron, C. P., & Griffiths, H. R. (2014) · Free Radical Research · doi:10.3109/10715762.2014.944868 · Cited by 65
Metadata
- Authors
- Wang, P., & Powell, S. R.
- Venue
- Free Radical Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 49
- Issue
- 2
- Pages
- 119-121
- ISSN
- 0891-5849 (ISSN-L)
- OpenAlex
- W1993791064
- Cited by
- 38
- References
- 1
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Decreased sensitivity associated with an altered formulation of a commercially available kit for detection of protein carbonyls. https://app.cochat.ai/papers/10.1016/j.freeradbiomed.2010.03.005
- The paper
- Wang, P., & Powell, S. R. (2010). Decreased sensitivity associated with an altered formulation of a commercially available kit for detection of protein carbonyls. Free Radical Biology and Medicine. https://doi.org/10.1016/j.freeradbiomed.2010.03.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.