A simple method for calibrating force plates and force treadmills using an instrumented pole
Open accessThe DOI matches its Crossref record.
Abstract
We propose a new method for calibrating force plates to reduce errors in center of pressure locations, forces, and moments. These errors may be caused by imperfect mounting of force plates to the ground or by installation of a treadmill atop a force plate, which may introduce distorting loads. The method, termed the Post-Installation Least-Squares (PILS) calibration, combines features of several previous methods into a simple procedure. It requires a motion capture system and an instrumented pole for applying reference loads. Reference loads may be manually applied to the force plate in arbitrary locations and directions. The instrumented pole measures applied load magnitudes through a single-axis load cell, and load directions through motion capture markers. Reference data and imperfect force plate signals are then combined to form a linear calibration matrix that simultaneously minimizes mean square errors in all forces and moments. We applied the procedure to standard laboratory force plates, as well as a custom-built, split-belt force treadmill. We also collected an independent set of verification data for testing. The proposed calibration procedure was found to reduce force errors by over 20%, and moment errors by over 60%. Center of pressure errors were also reduced by 63% for standard force plates and 91% for the force treadmill. The instrumented pole is advantageous because it allows for fast and arbitrary load application without needing a precise fixture for aligning loads. The linear calibration matrix is simpler than nonlinear correction equations and more compatible with standard data acquisition software, yet it yields error reductions comparable to more complex methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481
Self-citationElectrocortical activity is coupled to gait cycle phase during treadmill walking
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.066 · Cited by 479
Self-citationDynamic arm swinging in human walking
Collins, S. H., Adamczyk, P. G., & Kuo, A. D. (2009) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2009.0664 · Cited by 406
Self-citationDirection-dependent control of balance during walking and standing
O'Connor, S. M., & Kuo, A. D. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00131.2009 · Cited by 393
Self-citationVisual Evoked Responses During Standing and Walking
Gramann, K., Gwin, J. T., Bigdely-Shamlo, N., Ferris, D. P., & Makeig, S. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00202 · Cited by 229
Self-citation
Metadata
- Authors
- Collins, S. H., Adamczyk, P. G., Ferris, D. P., & Kuo, A. D.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2009-01
- Volume
- 29
- Issue
- 1
- Pages
- 59-64
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2120803543
- Cited by
- 104
- References
- 0
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple method for calibrating force plates and force treadmills using an instrumented pole. https://app.cochat.ai/papers/10.1016/j.gaitpost.2008.06.010
- The paper
- Collins, S. H., Adamczyk, P. G., Ferris, D. P., & Kuo, A. D. (2009). A simple method for calibrating force plates and force treadmills using an instrumented pole. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2008.06.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.