CoChat

Reliability of ultrasound for measurement of selected foot structures

Open access
Crofts, G., Angin, S., Mickle, K.J., Hill, S., Nester, C.J. · 2014 · Gait & Posture
Cited by 165

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

BACKGROUND Understanding the relationship between the lower leg muscles, foot structures and function is essential to explain how disease or injury may relate to changes in foot function and clinical pathology. The aim of this study was to investigate the inter-operator reliability of an ultrasound protocol to quantify features of: rear, mid and forefoot sections of the plantar fascia (PF); flexor hallucis brevis (FHB); flexor digitorum brevis (FDB); abductor hallucis (AbH); flexor digitorum longus (FDL); flexor hallucis longus (FHL); tibialis anterior (TA); and peroneus longus and brevis (PER). METHODS A sample of 6 females and 4 males (mean age 29.1 ± 7.2 years, mean BMI 25.5 ± 4.8) was recruited from a university student and staff population. Scans were obtained using a portable Venue 40 musculoskeletal ultrasound system (GE Healthcare UK) with a 5-13 MHz wideband linear array probe with a 12.7 mm × 47.1mm footprint by two operators in the same scanning session. RESULTS Intraclass Correlation Coefficients (ICC) values for muscle thickness (ICC range 0.90-0.97), plantar fascia thickness (ICC range 0.94-0.98) and cross sectional muscle measurements (ICC range 0.91-0.98) revealed excellent inter-operator reliability. The limits of agreement, relative to structure size, ranged from 9.0% to 17.5% for muscle thickness, 11.0-18.0% for plantar fascia, and 11.0-26.0% for cross sectional area measurements. CONCLUSIONS The ultrasound protocol implemented in this work has been shown to be reliable. It therefore offers the opportunity to quantify the structures concerned and better understand their contributions to foot function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gaitpost.2013.05.022

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

  • The reliability and validity of ultrasound to quantify muscles in older adults: A systematic review

    Nijholt, W., Scafoglieri, A., Jager‐Wittenaar, H., Hobbelen, J. S. M., & van der Schans, C. P. (2017) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.12210 · Cited by 459

    “Furthermore, ultrasound has been shown to be reliable for assessing selected foot structures, which suggests that ultrasound has the potential to accurately assess (small) muscle groups.(15) Currently, it is difficult to diagnose sarcopenia in daily practice because there is a lack of valid and/or feasible tools for t…”
    Background

See all 165

Metadata

Authors
Crofts, G., Angin, S., Mickle, K. J., Hill, S., & Nester, C. J.
Venue
Gait & Posture
Publisher
Elsevier BV
Published
2014-01
Volume
39
Issue
1
Pages
35-39
ISSN
0966-6362 (ISSN-L)
OpenAlex
W2134023104
Cited by
165
References
23
FWCI
4.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.