The DOI matches its Crossref record.
Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking
Open accessAbstract
The measurement of gait parameters normally requires motion tracking systems combined with force plates, which limits the measurement to laboratory settings. In some recent studies, the possibility of using the portable, low cost, and marker-less Microsoft Kinect sensor to measure gait parameters on over-ground walking has been examined. The current study further examined the accuracy level of the Kinect sensor for assessment of various gait parameters during treadmill walking under different walking speeds. Twenty healthy participants walked on the treadmill and their full body kinematics data were measured by a Kinect sensor and a motion tracking system, concurrently. Spatiotemporal gait parameters and knee and hip joint angles were extracted from the two devices and were compared. The results showed that the accuracy levels when using the Kinect sensor varied across the gait parameters. Average heel strike frame errors were 0.18 and 0.30 frames for the right and left foot, respectively, while average toe off frame errors were -2.25 and -2.61 frames, respectively, across all participants and all walking speeds. The temporal gait parameters based purely on heel strike have less error than the temporal gait parameters based on toe off. The Kinect sensor can follow the trend of the joint trajectories for the knee and hip joints, though there was substantial error in magnitudes. The walking speed was also found to significantly affect the identified timing of toe off. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure some gait parameters for treadmill walking, depending on the desired accuracy level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validity and repeatability of inertial measurement units for measuring gait parameters
Washabaugh, E. P., Kalyanaraman, T., Adamczyk, P. G., Claflin, E. S., & Krishnan, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.013 · Cited by 329
Deep neural networks enable quantitative movement analysis using single-camera videos
Kidziński, Ł., Yang, B., Hicks, J. L., Rajagopal, A., Delp, S. L., & Schwartz, M. H. (2020) · Nature Communications · doi:10.1038/s41467-020-17807-z · Cited by 321
Two-dimensional video-based analysis of human gait using pose estimation
Stenum, J., Rossi, C., & Roemmich, R. T. (2021) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1008935 · Cited by 321
Albert, J. A., Owolabi, V., Gebel, A., Brahms, C. M., Granacher, U., & Arnrich, B. (2020) · Sensors · doi:10.3390/s20185104 · Cited by 261
Yeo, S. S., & Park, G. Y. (2020) · Sensors · doi:10.3390/s20051343 · Cited by 56
Metadata
- Authors
- Xu, X., McGorry, R. W., Chou, L.-S., Lin, J.-H., & Chang, C.-C.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2015-07
- Volume
- 42
- Issue
- 2
- Pages
- 145-151
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W1536165553
- Cited by
- 239
- References
- 0
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking. https://app.cochat.ai/papers/10.1016/j.gaitpost.2015.05.002
- The paper
- Xu, X., McGorry, R. W., Chou, L.-S., Lin, J.-H., & Chang, C.-C. (2015). Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2015.05.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.