Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The measurement of gait parameters normally requires motion tracking systems combined with force plates, which limits the measurement to laboratory settings. In some recent studies, the possibility of using the portable, low cost, and marker-less Microsoft Kinect sensor to measure gait parameters on over-ground walking has been examined. The current study further examined the accuracy level of the Kinect sensor for assessment of various gait parameters during treadmill walking under different walking speeds. Twenty healthy participants walked on the treadmill and their full body kinematics data were measured by a Kinect sensor and a motion tracking system, concurrently. Spatiotemporal gait parameters and knee and hip joint angles were extracted from the two devices and were compared. The results showed that the accuracy levels when using the Kinect sensor varied across the gait parameters. Average heel strike frame errors were 0.18 and 0.30 frames for the right and left foot, respectively, while average toe off frame errors were -2.25 and -2.61 frames, respectively, across all participants and all walking speeds. The temporal gait parameters based purely on heel strike have less error than the temporal gait parameters based on toe off. The Kinect sensor can follow the trend of the joint trajectories for the knee and hip joints, though there was substantial error in magnitudes. The walking speed was also found to significantly affect the identified timing of toe off. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure some gait parameters for treadmill walking, depending on the desired accuracy level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,558
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242
Zeni, J. A., Richards, J. G., & Higginson, J. S. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.07.007 · Cited by 1,261
The reliability of three-dimensional kinematic gait measurements: A systematic review
McGinley, J. L., Baker, R., Wolfe, R., & Morris, M. E. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.09.003 · Cited by 1,144 · cited 1×
“Given that a joint angle difference greater than 58 is considered a clinically significant difference [20], the results of the current study seem to suggest that knee and joint angles measured directly with the Kinect sensor cannot be used for clinical gait analysis.”
MethodData analysis 2Preprint
Wagemans, F. M. A., Brandt, M. J., & Zeelenberg, M. (2016) · Cited by 952
Gait Analysis: An Introduction
Whittle, M. W. (1986) · Cited by 925
Validity of the Microsoft Kinect for assessment of postural control
Clark, R. A., Pua, Y.-H., Fortin, K., Ritchie, C., Webster, K. E., Denehy, L., & Bryant, A. L. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.03.033 · Cited by 687 · cited 2×
“Because the Kinect sensor is low cost and portable, some researchers have examined the validity of the Kinect sensor [5] and the possibility of adopting it for biomechanics studies [6–8].”
BackgroundMethodGait characteristics of patients with knee osteoarthritis
Kaufman, K. R., Hughes, C., Morrey, B. F., Morrey, M., & An, K.-N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00036-7 · Cited by 676 · cited 1×
“These parameters have been used for different purposes including representation of diseases [1,2], quantifying rehabilitation effectiveness [3], and investigating the effect of load carrying [4].”
BackgroundComparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis
Pfister, A., West, A. M., Bronner, S., & Noah, J. A. (2014) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2014.909540 · Cited by 552 · cited 3×
“Some previous studies [9–12] investigated the validity of the Kinect sensor for assessment of gait parameters.”
BackgroundEvaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace
Dutta, T. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2011.09.011 · Cited by 435 · cited 3×
“One possible explanation is that as the Kinect sensor had less measurement error for objects closest to the sensor [5], the forward half of the treadmill belt, where HS occurs, is more easily observed than the aft half of the treadmill where TO occurs (Fig.”
BackgroundAccuracy and robustness of Kinect pose estimation in the context of coaching of elderly population
Obdrzalek, S., Kurillo, G., Ofli, F., Bajcsy, R., Seto, E., Jimison, H., & Pavel, M. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346149 · Cited by 319
Gait analysis during treadmill and overground locomotion in children and adults
Stolze, H., Kuhtz-Buschbeck, J. P., Mondwurf, C., Boczek-Funcke, A., Jöhnk, K., Deuschl, G., & Illert, M. (1997) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/s0924-980x(97)00055-6 · Cited by 277 · cited 1×
“However, walking patterns on treadmills may differ from that of over-ground walking [16].”
BackgroundBonnechère, B., Jansen, B., Salvia, P., Bouzahouene, H., Omelina, L., Moiseev, F., Sholukha, V., Cornelis, J., Rooze, M., & Van Sint Jan, S. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.09.018 · Cited by 267 · cited 1×
“Because the Kinect sensor is low cost and portable, some researchers have examined the validity of the Kinect sensor [5] and the possibility of adopting it for biomechanics studies [6–8].”
BackgroundConcurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables
Clark, R. A., Bower, K. J., Mentiplay, B. F., Paterson, K., & Pua, Y.-H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.08.011 · Cited by 234 · cited 4×
“In a previous study [11] where the validity of Kinect sensor-based gait parameters were examined for over-ground walking, mean error of step and stride times were 0.”
BackgroundMethodInfluentialAbnormalities in the stride length‐cadence relation in parkinsonian gait
Morris, M., Iansek, R., Matyas, T., & Summers, J. (1998) · Movement Disorders · doi:10.1002/mds.870130115 · Cited by 223
Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining
Clark, R. A., Pua, Y.-H., Bryant, A. L., & Hunt, M. A. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.03.029 · Cited by 178
The neural underpinnings of vicarious experience
Fitzgibbon, B. M., Ward, J., & Enticott, P. G. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00384 · Cited by 168
Effects of adding a virtual reality environment to different modes of treadmill walking
Sloot, L. H., van der Krogt, M. M., & Harlaar, J. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.12.005 · Cited by 106
Begg, R. K., Tirosh, O., Said, C. M., Sparrow, W. A., Steinberg, N., Levinger, P., & Galea, M. P. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00243 · Cited by 73 · cited 1×
“While some gait studies are based on over-ground walking, a number of other studies are based on treadmill walking [13–15].”
MethodNormalized gait parameters in NDT-Bobath post-stroke gait rehabilitation
Mikołajewska, E. (2012) · Open Medicine · doi:10.2478/s11536-011-0138-6 · Cited by 14 · cited 1×
“These parameters have been used for different purposes including representation of diseases [1,2], quantifying rehabilitation effectiveness [3], and investigating the effect of load carrying [4].”
Background
Cited by
Validity and repeatability of inertial measurement units for measuring gait parameters
Washabaugh, E. P., Kalyanaraman, T., Adamczyk, P. G., Claflin, E. S., & Krishnan, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.013 · Cited by 329
Deep neural networks enable quantitative movement analysis using single-camera videos
Kidziński, Ł., Yang, B., Hicks, J. L., Rajagopal, A., Delp, S. L., & Schwartz, M. H. (2020) · Nature Communications · doi:10.1038/s41467-020-17807-z · Cited by 321
Two-dimensional video-based analysis of human gait using pose estimation
Stenum, J., Rossi, C., & Roemmich, R. T. (2021) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1008935 · Cited by 321
Albert, J. A., Owolabi, V., Gebel, A., Brahms, C. M., Granacher, U., & Arnrich, B. (2020) · Sensors · doi:10.3390/s20185104 · Cited by 261
Real time RULA assessment using Kinect v2 sensor
Manghisi, V. M., Uva, A. E., Fiorentino, M., Bevilacqua, V., Trotta, G. F., & Monno, G. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.02.015 · Cited by 207
Metadata
- Authors
- Xu, X., McGorry, R. W., Chou, L.-S., Lin, J.-H., & Chang, C.-C.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2015-07
- Volume
- 42
- Issue
- 2
- Pages
- 145-151
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W1536165553
- Cited by
- 239
- References
- 21
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.