Comparison of physical activity assessed using hip- and wrist-worn accelerometers
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Objectives It is unclear how physical activity estimates differ when assessed using hip- versus wrist-worn accelerometers. The objective of this study was to compare physical activity assessed by hip- and wrist-worn accelerometers in free-living older women. Design A cross-sectional study collecting data in free-living environment. Methods Participants were from the Women’s Health Study, in which an ancillary study is objectively measuring physical activity using accelerometers (ActiGraph GT3X+). We analyzed data from 94 women (mean (SD) age=71.9 (6.0) years) who wore a hip-worn and wrist-worn accelerometers simultaneously for 7 days. Results Using triaxial data (vector magnitude, VM), total activity volume (counts per day) between the two locations was moderately correlated (Spearman’s r=0.73). Hip and wrist monitors wear locations identically classified 71% individuals who were at the highest 40% or lowest 40% of their respective distributions. Similar patterns and slightly stronger agreements were observed when examining steps instead of VM counts. Conclusions Accelerometer-assessed physical activity using hip- versus wrist-worn devices was moderately correlated in older, free-living women. However, further research needs to be conducted to examine comparisons of specific activities or physical activity intensity levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Self-citationPhysical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 2×
“Discussion While hip-worn accelerometers have traditionally been used in PA research settings, wristworn devices have recently become greater utilized due to expected higher compliance [4, 18].”
Global physical activity levels: surveillance progress, pitfalls, and prospects
Hallal, P. C., Andersen, L. B., Bull, F. C., Guthold, R., Haskell, W., & Ekelund, U. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60646-1 · Cited by 5,711 · cited 1×
“Monitoring physical activity (PA) on a population-wide scale, in addition to conducting observational and experimental studies, has become a key element of public health practice due to the multitude of health benefits associated with PA [1] and the increasing prevalence of physical inactivity [2].”
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 1×
“Adult cutpoints for the ActiGraph when worn at the hip have been developed in laboratory settings using metabolic metrics as comparisons [6, 20].”
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317 · cited 13×
“As similar cutpoints do not exist for the wrist, we calculated sedentary time and MVPA over a range of arbitrary cutpoints.”
InfluentialLee, I.-M., Cook, N. R., Gaziano, J. M., Gordon, D., Ridker, P. M., Manson, J. E., Hennekens, C. H., & Buring, J. E. (2005) · JAMA · doi:10.1001/jama.294.1.56 · Cited by 1,137
Self-citationCook, N. R., Lee, I.-M., Gaziano, J. M., Gordon, D., Ridker, P. M., Manson, J. E., Hennekens, C. H., & Buring, J. E. (2005) · JAMA · doi:10.1001/jama.294.1.47 · Cited by 796 · cited 1×
“The Women’s Health Study (WHS) is a completed, randomized controlled trial of low-dose aspirin and vitamin E in the primary prevention of cardiovascular disease and cancer among 39,876 healthy women aged ≥45 years in the US, conducted between 1992 and 2004 [13, 14].”
Self-citationLee, I.-M., & Shiroma, E. J. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093154 · Cited by 415 · cited 3×
“However, previous analyses of accelerometer data from the WHS participants showed similar levels of PA and sedentary behaviour to a comparably-aged US national sample [3, 26, 27].”
Self-citationActivity Recognition Using a Single Accelerometer Placed at the Wrist or Ankle
MANNINI, A., INTILLE, S. S., ROSENBERGER, M., SABATINI, A. M., & HASKELL, W. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829736d6 · Cited by 383
Cited by
Chastin, S., McGregor, D., Palarea-Albaladejo, J., Diaz, K. M., Hagströmer, M., Hallal, P. C., van Hees, V. T., Hooker, S., Howard, V. J., Lee, I.-M., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-102345 · Cited by 162
Self-citationComparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents.
Scott, J. J., Rowlands, A. V., Cliff, D. P., Morgan, P. J., Plotnikoff, R. C., & Lubans, D. R. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.04.017 · Cited by 120
Collins, J. E., Yang, H. Y., Trentadue, T. P., Gong, Y., & Losina, E. (2019) · PLOS ONE · doi:10.1371/journal.pone.0211231 · Cited by 55
“It has been validated to provide objective measures of sedentary behavior and PA in free-living conditions and can be worn on the wrist (AGW) or hip (AGH)[10, 25, 26].”
BackgroundEarly postpartum physical activity and pelvic floor support and symptoms 1 year postpartum
Nygaard, I. E., Wolpern, A., Bardsley, T., Egger, M. J., & Shaw, J. M. (2021) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.08.033 · Cited by 48
Comparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30
Metadata
- Authors
- Kamada, M., Shiroma, E. J., Harris, T. B., & Lee, I.-M.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 44
- Pages
- 23-28
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2177314043
- Cited by
- 151
- References
- 12
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.