Gait event detection in laboratory and real life settings: Accuracy of ankle and waist sensor based methods
Open accessThe DOI matches its Crossref record.
Abstract
Wearable sensors technology based on inertial measurement units (IMUs) is leading the transition from laboratory-based gait analysis, to daily life gait monitoring. However, the validity of IMU-based methods for the detection of gait events has only been tested in laboratory settings, which may not reproduce real life walking patterns. The aim of this study was to evaluate the accuracy of two algorithms for the detection of gait events and temporal parameters during free-living walking, one based on two shank-worn inertial sensors, and the other based on one waist-worn sensor. The algorithms were applied to gait data of ten healthy subjects walking both indoor and outdoor, and completing protocols that entailed both straight supervised and free walking in an urban environment. The values obtained from the inertial sensors were compared to pressure insoles data. The shank-based method showed very accurate initial contact, stride time and step time estimation (<14ms error). Accuracy of final contact timings and stance time was lower (28-51ms error range). The error of temporal parameter variability estimates was in the range 0.09-0.89%. The waist method failed to detect about 1% of the total steps and performed worse than the shank method, but the temporal parameter estimation was still satisfactory. Both methods showed negligible differences in their accuracy when the different experimental conditions were compared, which suggests their applicability in the analysis of free-living gait.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Long-term unsupervised mobility assessment in movement disorders
Warmerdam, E., Hausdorff, J. M., Atrsaei, A., Zhou, Y., Mirelman, A., Aminian, K., Espay, A. J., Hansen, C., Evers, L. J. W., Keller, A., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30397-7 · Cited by 306
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
Celik, Y., Stuart, S., Woo, W., Sejdic, E., & Godfrey, A. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.09.016 · Cited by 83
Palmerini, L., Reggi, L., Bonci, T., Del Din, S., Micó-Amigo, M. E., Salis, F., Bertuletti, S., Caruso, M., Cereatti, A., Gazit, E., et al. (2023) · Scientific Data · doi:10.1038/s41597-023-01930-9 · Cited by 52
Self-citation
Metadata
- Authors
- Storm, F. A., Buckley, C. J., & Mazzà, C.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2016-10
- Volume
- 50
- Pages
- 42-46
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2507174161
- Cited by
- 182
- References
- 0
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gait event detection in laboratory and real life settings: Accuracy of ankle and waist sensor based methods. https://app.cochat.ai/papers/10.1016/j.gaitpost.2016.08.012
- The paper
- Storm, F. A., Buckley, C. J., & Mazzà, C. (2016). Gait event detection in laboratory and real life settings: Accuracy of ankle and waist sensor based methods. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2016.08.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.