The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Clinical efficacy of instrumented gait analysis: Systematic review 2020 update
Abstract
BACKGROUND This paper updates our 2011 systematic review on the clinical efficacy of three-dimensional instrumented gait analysis (3DGA). RESEARCH QUESTION What is the current evidence base pertaining to the clinical efficacy of 3DGA? METHODS We identified English language articles published from September 2009 to October 2019 reporting primary research that used typical motion analysis laboratory methods to study human walking. Five gait laboratory experts classified articles according to the highest type of efficacy they addressed: type 1 (technical), 2 (diagnostic accuracy), 2b (outcome prediction), 3-4 (diagnostic thinking and treatment), 5 (patient outcome), 6 (societal). Articles classified into type 3-4 and higher were rated for quality using LEGEND. RESULTS Of 2712 articles related to the efficacy of 3DGA, over 99% addressed technical (n = 313), diagnostic (n = 1466), or outcome prediction (n = 927) efficacy. Six type 3-4 studies showed that 3DGA changes treatment plans, increases clinicians' confidence in their treatment decisions, and increases agreement among clinicians. Two type 5 articles based on a randomized controlled trial demonstrated that patient outcomes improved only when 3DGA data were available and its recommendations were followed. A population-based type 5 study found that the incidence of severe crouch gait dropped from 25% to 4% following practice changes including the addition of 3DGA. The strength of evidence was mainly 3b (lesser quality prospective cohort studies) but also included stronger studies (three level 2 controlled clinical trials). SIGNIFICANCE Literature related to the clinical efficacy of 3DGA has grown substantially over the last decade. Thousands of articles contribute to continued improvement of data collection and interpretation, as well as understanding of gait pathology and treatment. A smaller number of studies clearly demonstrate the efficacy of 3DGA in changing and reinforcing treatment decisions, increasing clinicians' confidence in treatment planning, and increasing agreement among clinicians, as well as the potential to improve patient outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in evidence-based medicine: a quarter century on
Djulbegovic, B., & Guyatt, G. H. (2017) · The Lancet · doi:10.1016/s0140-6736(16)31592-6 · Cited by 1,022
Cited by
Hulleck, A. A., Menoth Mohan, D., Abdallah, N., El Rich, M., & Khalaf, K. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.901331 · Cited by 281
MXenes for wearable pressure sensing: Progress and prospects in human motion detection
Kong, X., Fan, C., Liao, K., Zhang, W., & Xiong, H. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.01.086 · Cited by 7
Metadata
- Authors
- Wren, T. A. L., Tucker, C. A., Rethlefsen, S. A., Gorton, G. E., & Õunpuu, S.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 80
- Pages
- 274-279
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W3026905460
- Cited by
- 161
- References
- 1
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical efficacy of instrumented gait analysis: Systematic review 2020 update. https://app.cochat.ai/papers/10.1016/j.gaitpost.2020.05.031
- The paper
- Wren, T. A. L., Tucker, C. A., Rethlefsen, S. A., Gorton, G. E., & Õunpuu, S. (2020). Clinical efficacy of instrumented gait analysis: Systematic review 2020 update. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2020.05.031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.