Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 354

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Application of convolutional neural network in the diagnosis of the invasion depth of gastric cancer based on conventional endoscopy

Zhu, Yan, Wang, Qiu-Cheng, Xu, Mei-Dong, Zhang, Zhen, Cheng, Jing, Zhong, Yun-Shi, Zhang, Yi-Qun, Chen, Wei-Feng, Yao, Li-Qing, Zhou, Ping-Hong, Li, Quan-Lin·2019·Gastrointestinal Endoscopy

Abstract

BACKGROUND AND AIMS According to guidelines, endoscopic resection should only be performed for patients whose early gastric cancer invasion depth is within the mucosa or submucosa of the stomach regardless of lymph node involvement. The accurate prediction of invasion depth based on endoscopic images is crucial for screening patients for endoscopic resection. We constructed a convolutional neural network computer-aided detection (CNN-CAD) system based on endoscopic images to determine invasion depth and screen patients for endoscopic resection. METHODS Endoscopic images of gastric cancer tumors were obtained from the Endoscopy Center of Zhongshan Hospital. An artificial intelligence-based CNN-CAD system was developed through transfer learning leveraging a state-of-the-art pretrained CNN architecture, ResNet50. A total of 790 images served as a development dataset and another 203 images as a test dataset. We used the CNN-CAD system to determine the invasion depth of gastric cancer and evaluated the system's classification accuracy by calculating its sensitivity, specificity, and area under the receiver operating characteristic curve. RESULTS The area under the receiver operating characteristic curve for the CNN-CAD system was .94 (95% confidence interval [CI], .90-.97). At a threshold value of .5, sensitivity was 76.47%, and specificity 95.56%. Overall accuracy was 89.16%. Positive and negative predictive values were 89.66% and 88.97%, respectively. The CNN-CAD system achieved significantly higher accuracy (by 17.25%; 95% CI, 11.63-22.59) and specificity (by 32.21%; 95% CI, 26.78-37.44) than human endoscopists. CONCLUSIONS We constructed a CNN-CAD system to determine the invasion depth of gastric cancer with high accuracy and specificity. This system distinguished early gastric cancer from deeper submucosal invasion and minimized overestimation of invasion depth, which could reduce unnecessary gastrectomy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2018.11.011

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 354

Metadata

Authors
Zhu, Y., Wang, Q.-C., Xu, M.-D., Zhang, Z., Cheng, J., Zhong, Y.-S., Zhang, Y.-Q., Chen, W.-F., Yao, L.-Q., Zhou, P.-H., & Li, Q.-L.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2019-04
Volume
89
Issue
4
Pages
806-815.e1
ISSN
0016-5107 (ISSN-L)
OpenAlex
W2900992792
Cited by
354
References
18
FWCI
22.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of convolutional neural network in the diagnosis of the invasion depth of gastric cancer based on conventional endoscopy. https://app.cochat.ai/papers/10.1016/j.gie.2018.11.011
The paper
Zhu, Y., Wang, Q.-C., Xu, M.-D., Zhang, Z., Cheng, J., Zhong, Y.-S., Zhang, Y.-Q., Chen, W.-F., Yao, L.-Q., Zhou, P.-H., & Li, Q.-L. (2019). Application of convolutional neural network in the diagnosis of the invasion depth of gastric cancer based on conventional endoscopy. Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2018.11.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.