CoChat

Comparing blind spots of unsedated ultrafine, sedated, and unsedated conventional gastroscopy with and without artificial intelligence: a prospective, single-blind, 3-parallel-group, randomized, single-center trial

Chen, Di, Wu, Lianlian, Li, Yanxia, Zhang, Jun, Liu, Jun, Huang, Li, Jiang, Xiaoda, Huang, Xu, Mu, Ganggang, Hu, Shan, Hu, Xiao, Gong, Dexin, He, Xinqi, Yu, Honggang · 2020 · Gastrointestinal Endoscopy
Cited by 95

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND AIMS Esophagogastroduodenoscopy (EGD) is the most vital procedure for the diagnosis of upper GI lesions. We aimed to compare the performance of unsedated ultrathin transoral endoscopy (U-TOE), unsedated conventional EGD (C-EGD), and sedated C-EGD, with or without the use of an artificial intelligence (AI) system. METHODS In this prospective, single-blind, 3-parallel-group, randomized, single-center trial, 437 patients scheduled to undergo outpatient EGD were randomized to unsedated U-TOE, unsedated C-EGD, or sedated C-EGD, and each group was then divided into 2 subgroups: with or without the assistance of an AI system to monitor blind spots during EGD. The primary outcome was the blind spot rate of these 3 groups with the assistance of AI. The secondary outcomes were to compare blind spot rates of unsedated U-TOE, unsedated, and sedated C-EGD with or without the assistance of AI, respectively, and the concordance between AI and the endoscopists' review. RESULTS The blind spot rate with AI-assisted sedated C-EGD was significantly lower than that of U-TOE and unsedated C-EGD (3.42% vs 21.77% vs 31.23%; P < .05). The blind spot rate of AI subgroup was lower than that of the control subgroup in all 3 groups (sedated C-EGD: 3.42% vs 22.46%; P < .001; U-TOE: 21.77% vs 29.92%, P < .001; unsedated C-EGD: 31.23% vs 42.46%, P < .001). CONCLUSIONS The blind spot rate of sedated C-EGD was the lowest among the 3 types of EGD, and the addition of AI had a maximal effect on sedated C-EGD. (Clinical trial registration number: ChiCTR1900020920.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2019.09.016

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 95

Metadata

Authors
Chen, D., Wu, L., Li, Y., Zhang, J., Liu, J., Huang, L., Jiang, X., Huang, X., Mu, G., Hu, S., Hu, X., Gong, D., He, X., & Yu, H.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2020-02
Volume
91
Issue
2
Pages
332-339.e3
ISSN
0016-5107 (ISSN-L)
OpenAlex
W2974808167
Cited by
95
References
2
FWCI
9.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparing blind spots of unsedated ultrafine, sedated, and unsedated conventional gastroscopy with and without artificial intelligence: a prospective, single-blind, 3-parallel-group, randomized, single-center trial. https://app.cochat.ai/papers/10.1016/j.gie.2019.09.016
The paper
Chen, D., Wu, L., Li, Y., Zhang, J., Liu, J., Huang, L., Jiang, X., Huang, X., Mu, G., Hu, S., Hu, X., Gong, D., He, X., & Yu, H. (2020). Comparing blind spots of unsedated ultrafine, sedated, and unsedated conventional gastroscopy with and without artificial intelligence: a prospective, single-blind, 3-parallel-group, randomized, single-center trial. Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2019.09.016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.