Sample size in quantitative instrument validation studies: A systematic review of articles published in Scopus, 2021
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background: Due to the range of conflicting criteria regarding minimum sample size needed for a scale/questionnaire validation study, the objective of this review is to analyze sample sizes used in published journal articles to contribute a pragmatic perspective to the discussion on sample sizes. Methods: A sample of 1999 articles published in a Scopus-indexed journal about the validation of a scale or questionnaire during 2021 were analyzed for this study. Abstracts from these articles were tabulated by two data entry professionals and any discrepancies were reviewed by the author. The sample size data was grouped by highest quartile of the journal publishing the article and further sub-categorized based on the inclusion of medical patients or students in each study's population. Results: From the total sample, 1750 articles provided sufficient information in their summary to determine the sample size used. Of these, the majority were published in quartile 1 (784) and quartile 2 (620) journals. Mean values by quartile ranged from 389 (quartile 3) to 2032 (quartile 1), but extreme outliers limited the usefulness of the simple mean. Thus, outlier-removed means were calculated, and in most cases, these sample size values were higher for studies involving students and lower for studies involving patients. Discussion: This study is limited by its focus on a single database and by including all phases of validation from initial quantitative instrument design studies (which tend to have the lowest sample sizes) up to international macro-studies (which can have hundreds of thousands of participants.) Nevertheless, the results of this study provide an additional practical perspective for the academic discussion regarding minimum sample size based on accepted practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wolf, E. J., Harrington, K. M., Clark, S. L., & Miller, M. W. (2013) · Educational and Psychological Measurement · doi:10.1177/0013164413495237 · Cited by 3,931
A First Course in Factor Analysis
Price, B. (1993) · Technometrics · doi:10.1080/00401706.1993.10485363 · Cited by 3,512
An easy guide to factor analysis
Gudjonsson, G. (1994) · Personality and Individual Differences · doi:10.1016/0191-8869(94)90040-x · Cited by 1,938
Kyriazos, T. A. (2018) · Psychology · doi:10.4236/psych.2018.98126 · Cited by 1,882 · cited 1×
“For a theoretical perspective including p value, power, and effect, see Whitley and Ball (2002) and for a summary of a wide range of approaches including Monte Carlo simulation studies regarding sample size, see Kyriazos and Kyriazos (2018).”
BackgroundMinimum Sample Size Recommendations for Conducting Factor Analyses
Mundfrom, D. J., Shaw, D. G., & Ke, T. L. (2005) · International Journal of Testing · doi:10.1207/s15327574ijt0502_4 · Cited by 1,704 · cited 3×
“Mundfrom et al. (2009) used simulation studies to evaluate the minimum sample size needed for factor analysis of a single instrument, and found that a higher number of factors leads to a higher sample size requirement, whereas a higher number of items per factor leads to a lower minimum sample size.”
BackgroundMethodResultAnthoine, E., Moret, L., Regnault, A., Sébille, V., & Hardouin, J.-B. (2014) · Health and Quality of Life Outcomes · doi:10.1186/s12955-014-0176-2 · Cited by 1,130 · cited 9×
“Anthoine et al. (2014) call for simulation studies to provide more information to help set a minimum sample size for different circumstances, and some such studies have indeed been done. Mundfrom et al. (2009) used simulation studies to evaluate the minimum sample size needed for factor analysis of a single instrument…”
BackgroundResultInfluentialStatistics review 4: sample size calculations.
Whitley, E., & Ball, J. (2002) · Critical Care · doi:10.1186/cc1521 · Cited by 773
Multivariate Analysis: The Need for Data, and other Problems
Everitt, B. S. (1975) · British Journal of Psychiatry · doi:10.1192/bjp.126.3.237 · Cited by 772 · cited 2×
“Over the years, there have been several proposals for “rules of thumb” such as 10 participants for every question in the instrument (Everitt, 1975), a simple flat minimum (with a few caveats like good model fit) of 100 participants (Kline, 1994), or a range from 50 as very poor through 300 as good up to 1000 or more a…”
BackgroundCurrent sample size conventions: Flaws, harms, and alternatives
Bacchetti, P. (2010) · BMC Medicine · doi:10.1186/1741-7015-8-17 · Cited by 232 · cited 9×
“Based on the current of thought expressed by publications like Silva Ayçaguer and Alonso Galb an (2013) and Bacchetti (2010), this study makes no attempt to judge or categorize the analyzed articles into “sufficient” or “insufficient” sample sizes.”
BackgroundMethodInfluentialExplicación del tamaño muestral empleado: una exigencia irracional de las revistas biomédicas
Ayçaguer, L. C. S., & Galbán, P. A. (2012) · Gaceta Sanitaria · doi:10.1016/j.gaceta.2012.01.017 · Cited by 19
Metadata
- Authors
- White, M.
- Venue
- Heliyon
- Publisher
- Elsevier BV
- Published
- 2022-12
- Volume
- 8
- Issue
- 12
- Pages
- e12223
- ISSN
- 2405-8440 (ISSN-L)
- OpenAlex
- W4312055783
- Cited by
- 203
- References
- 10
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.