The DOI matches its Crossref record; 128 of the 128 references it cites were found in a registry or an index.
Nanomaterials-based biosensor and their applications: A review
Open accessAbstract
A sensor can be called ideal or perfect if it is enriched with certain characteristics viz., superior detections range, high sensitivity, selectivity, resolution, reproducibility, repeatability, and response time with good flow. Recently, biosensors made of nanoparticles (NPs) have gained very high popularity due to their excellent applications in nearly all the fields of science and technology. The use of NPs in the biosensor is usually done to fill the gap between the converter and the bioreceptor, which is at the nanoscale. Simultaneously the uses of NPs and electrochemical techniques have led to the emergence of biosensors with high sensitivity and decomposition power. This review summarizes the development of biosensors made of NPssuch as noble metal NPs and metal oxide NPs, nanowires (NWs), nanorods (NRs), carbon nanotubes (CNTs), quantum dots (QDs), and dendrimers and their recent advancement in biosensing technology with the expansion of nanotechnology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Effect of Crystallographic Structure of MnO 2 on Its Electrochemical Capacitance Properties
Devaraj, S., & Munichandraiah, N. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp7108785 · Cited by 1,385
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Dendrimers: synthesis, applications, and properties
Abbasi, E., Aval, S. F., Akbarzadeh, A., Milani, M., Nasrabadi, H. T., Joo, S. W., Hanifehpour, Y., Nejati-Koshki, K., & Pashaei-Asl, R. (2014) · Nanoscale Research Letters · doi:10.1186/1556-276x-9-247 · Cited by 1,279
Electrochemical Biosensors: Recommended Definitions and Classification
Thevenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S. (1999) · Pure and Applied Chemistry · doi:10.1351/pac199971122333 · Cited by 909
Zhang, R., & Chen, W. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.074 · Cited by 879
Gold nanorod-based localized surface plasmon resonance biosensors: A review
Cao, J., Sun, T., & Grattan, K. T. V. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.056 · Cited by 768
Patolsky, F., Zheng, G., & Lieber, C. M. (2006) · Analytical Chemistry · doi:10.1021/ac069419j · Cited by 710
Cited by
Enhancing the sustainability of microalgae cultivation through biosensing technology
Ugya, A. Y., Chen, H., & Wang, Q. (2025) · Materials Today Sustainability · doi:10.1016/j.mtsust.2025.101139 · Cited by 5
Metadata
- Authors
- Malik, S., Singh, J., Goyat, R., Saharan, Y., Chaudhry, V., Umar, A., Ibrahim, A. A., Akbar, S., Ameen, S., & Baskoutas, S.
- Venue
- Heliyon
- Publisher
- Elsevier BV
- Published
- 2023-09
- Volume
- 9
- Issue
- 9
- Pages
- e19929
- ISSN
- 2405-8440 (ISSN-L)
- OpenAlex
- W4386498843
- Cited by
- 441
- References
- 128
- FWCI
- 32.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanomaterials-based biosensor and their applications: A review. https://app.cochat.ai/papers/10.1016/j.heliyon.2023.e19929
- The paper
- Malik, S., Singh, J., Goyat, R., Saharan, Y., Chaudhry, V., Umar, A., Ibrahim, A. A., Akbar, S., Ameen, S., & Baskoutas, S. (2023). Nanomaterials-based biosensor and their applications: A review. Heliyon. https://doi.org/10.1016/j.heliyon.2023.e19929
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.