Evidence regarding clinical use of microvolt T-wave alternans
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND Microvolt T-wave alternans (MTWA) testing in many studies has proven to be a highly accurate predictor of ventricular tachyarrhythmic events (VTEs) in patients with risk factors for sudden cardiac death (SCD) but without a prior history of sustained VTEs (primary prevention patients). In some recent studies involving primary prevention patients with prophylactically implanted cardioverter-defibrillators (ICDs), MTWA has not performed as well. OBJECTIVE This study examined the hypothesis that MTWA is an accurate predictor of VTEs in primary prevention patients without implanted ICDs, but not of appropriate ICD therapy in such patients with implanted ICDs. METHODS This study identified prospective clinical trials evaluating MTWA measured using the spectral analytic method in primary prevention populations and analyzed studies in which: (1) few patients had implanted ICDs and as a result none or a small fraction (< or =15%) of the reported end point VTEs were appropriate ICD therapies (low ICD group), or (2) many of the patients had implanted ICDs and the majority of the reported end point VTEs were appropriate ICD therapies (high ICD group). RESULTS In the low ICD group comprising 3,682 patients, the hazard ratio associated with a nonnegative versus negative MTWA test was 13.6 (95% confidence interval [CI] 8.5 to 30.4) and the annual event rate among the MTWA-negative patients was 0.3% (95% CI: 0.1% to 0.5%). In contrast, in the high ICD group comprising 2,234 patients, the hazard ratio was only 1.6 (95% CI: 1.2 to 2.1) and the annual event rate among the MTWA-negative patients was elevated to 5.4% (95% CI: 4.1% to 6.7%). In support of these findings, we analyzed published data from the Multicenter Automatic Defibrillator Trial II (MADIT II) and Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) trials and determined that in those trials only 32% of patients who received appropriate ICD therapy averted an SCD. CONCLUSION This study found that MTWA testing using the spectral analytic method provides an accurate means of predicting VTEs in primary prevention patients without implanted ICDs; in particular, the event rate is very low among such patients with a negative MTWA test. In prospective trials of ICD therapy, the number of patients receiving appropriate ICD therapy greatly exceeds the number of patients who avert SCD as a result of ICD therapy. In trials involving patients with implanted ICDs, these excess appropriate ICD therapies seem to distribute randomly between MTWA-negative and MTWA-nonnegative patients, obscuring the predictive accuracy of MTWA for SCD. Appropriate ICD therapy is an unreliable surrogate end point for SCD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277
Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041489 · Cited by 1,519
Self-citationNoninvasive Risk Assessment Early After a Myocardial Infarction
Exner, D. V., Kavanagh, K. M., Slawnych, M. P., Mitchell, L. B., Ramadan, D., Aggarwal, S. G., Noullett, C., Van Schaik, A., Mitchell, R. T., Shibata, M. A., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.042 · Cited by 348
Grimm, W., Christ, M., Bach, J., Müller, H.-H., & Maisch, B. (2003) · Circulation · doi:10.1161/01.cir.0000100721.52503.85 · Cited by 321
Cited by
Verrier (2011) · doi:10.1016/j.jacc.2011.06.029 · Cited by 421
Ventricular repolarization measures for arrhythmic risk stratification
Monitillo, F. (2016) · World Journal of Cardiology · doi:10.4330/wjc.v8.i1.57 · Cited by 66
Dobson, C. P., Kim, A., & Haigney, M. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.07.004 · Cited by 51
Metadata
- Authors
- Hohnloser, S. H., Ikeda, T., & Cohen, R. J.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 6
- Issue
- 3
- Pages
- S36-S44
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W1988750762
- Cited by
- 90
- References
- 5
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence regarding clinical use of microvolt T-wave alternans. https://app.cochat.ai/papers/10.1016/j.hrthm.2008.10.011
- The paper
- Hohnloser, S. H., Ikeda, T., & Cohen, R. J. (2009). Evidence regarding clinical use of microvolt T-wave alternans. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2008.10.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.