Cited by 58Cardiac Arrhythmias and TreatmentsCardiac electrophysiology and arrhythmiasAtrial Fibrillation Management and Outcomes

Color-coded three-dimensional entrainment mapping for analysis and treatment of atrial macroreentrant tachycardia

Esato, Masahiro, Hindricks, Gerhard, Sommer, Philipp, Arya, Arash, Gaspar, Thomas, Bode, Kerstin, Bollmann, Andreas, Wetzel, Ulrike +4 more·2009·Heart Rhythm

Abstract

Background Mapping and ablation of atrial macroreentrant tachycardia focus on activation mapping with identification of the area of slow conduction.Objective The purpose of this study was to evaluate a new concept for analysis and treatment of macroreentrant tachycardia based on color-coded three-dimensional (3D) entrainment mapping and subsequent placement of strategic lesion lines.Methods Twenty-six patients presented with macroreentrant tachycardia (cycle length 329 +/- 70 ms). Using nonfluoroscopic systems (CARTO 12, NavX 14), sequential mapping of the target atrium was performed. On each mapping point, the 3D location was paired with color-coded entrainment information so that the reentrant circuit could be directly visualized.Results Procedural duration, fluoroscopy time, and radiofrequency time measured 181 +/- 58, 37 +/- 19, and 31 +/- 17 minutes, respectively. Thirty-nine macroreentrant tachycardias were ablated: perimitral 9, around pulmonary vein ostium 6, through left atrial roof 5, around left atrial appendage 3, right atrial cavotricuspid isthmus dependent 6, around right atrial scar 2, around superior vena cava 1, within the septum 5, and within the coronary sinus 2. Tachycardia termination and noninducibility of any macroreentrant tachycardia was the procedural end-point. In case of left atrial macroreentrant tachycardia, pulmonary vein isolation was completed. Follow-up with serial 7-day Holter covered 302 +/- 82 days. Two (8%) patients experienced recurrences of a pretreated macroreentrant tachycardia.Conclusion In patients with macroreentrant tachycardia, color-coded 3D entrainment mapping is feasible to accurately determine and visualize the 3D location of the reentrant circuit and to plan a strategic ablation line concept. That approach, not targeting the area of slow conduction of the circuit, resulted in excellent procedural success (100%), with long-term freedom from any tachycardia recurrences in 88% of patients.

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2008.12.013

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 15 · Cited by 58

Authors
Esato, M., Hindricks, G., Sommer, P., Arya, A., Gaspar, T., Bode, K., Bollmann, A., Wetzel, U., Hilbert, S., Kircher, S., Eitel, C., & Piorkowski, C.
Affiliations
Leipzig Heart Institute (DE)
Corresponding author
Piorkowski, Christopher
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2009-03
Volume
6
Issue
3
Pages
349-358
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2073500293
Cited by
58
References
15
Citations by year
2026: 1 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 8 · 2018: 3 · 2017: 1 · 2016: 3 · 2015: 3 · 2014: 4 · 2013: 2 · 2012: 11
FWCI
2.92
Type
journal article
Language
en
Open access
closed
Locations
  • Heart Rhythm (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
Keywords
radiofrequency catheter ablation, pulmonary vein isolation, left atrial tachycardia, atrial flutter, tachycardia recurrence
MeSH terms
Adult, Aged, Cardiac Pacing, Artificial, Female, Heart Atria, Heart Conduction System, Humans, Male, Middle Aged, Tachycardia, Catheter Ablation, Body Surface Potential Mapping, Imaging, Three-Dimensional, Electrophysiologic Techniques, Cardiac

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review