The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Temporal relationship of atrial tachyarrhythmias, cerebrovascular events, and systemic emboli based on stored device data: A subgroup analysis of TRENDS
Abstract
Background The temporal relationship between atrial tachyarrhythmias (atrial tachycardia [AT] and atrial fibrillation [AF]) and cerebrovascular events/systemic emboli (CVE/SE) is unknown.Objective The purpose of this study was to evaluate this relationship using stored AT/AF diagnostic data from implanted devices in patients with and those without AF.Methods The TRENDS study enrolled 2,486 patients with an indication for an implantable device, at least one stroke risk factor, and available device data. The current study includes the subgroup of 40 (1.6%) patients enrolled in TRENDS who experienced CVE/SE.Results AT/AF was detected prior to CVE/SE in 20 (50%) of 40 patients. Other than average and maximum daily AT/AF burden and duration of device monitoring prior to CVE/SE, no statistically significant differences were found between patients with and those without AT/AF prior to CVE/SE. For the 20 patients with AT/AF detected prior to CVE/SE, 9 (45%) did not have any AT/AF in the 30 days prior to CVE/SE. Therefore, 29 (73%) of 40 patients with CVE/SE had zero AT/AF burden within 30 days prior to CVE/SE. Fourteen (70%) of the 20 patients with AT/AF detected prior to CVE/SE were not in AT/AF at diagnosis of CVE/SE. The last episode of AT/AF in these 14 patients was 168 ± 199 days (range 3-642 days) before CVE/SE.Conclusion The majority of CVE/SE in this population did not occur proximal to recent AT/AF episodes. These data imply that the mechanisms of CVE/SE in patients with implantable devices may importantly involve mechanisms other than cardioembolism due to atrial tachyarrhythmias.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Strokes often occur without AHRE detected within 30 days before the event.143-147”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [146]
Citations
Cites
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Gage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H. G., Brugada, J., Packer, D. L., Cappato, R., Chen, S., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Haines, D. E., Haı̈ssaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,690
Calkins, H. G., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Haines, D. E., Haïssaguerre, M., et al. (2007) · EP Europace · doi:10.1093/europace/eum120 · Cited by 1,289
Mechanisms of thrombogenesis in atrial fibrillation: Virchow's triad revisited
Watson, T., Shantsila, E., & Lip, G. Y. H. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60040-4 · Cited by 1,124
Marini, C., De Santis, F., Sacco, S., Russo, T., Olivieri, L., Totaro, R., & Carolei, A. (2005) · Stroke · doi:10.1161/01.str.0000166053.83476.4a · Cited by 949
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879 · cited 2×
“5 hours in any 30-day period doubled CVE/SE risk.(7) However, in the current study, patient-specific analysis revealed that only 50% of patients who experienced CVE/SE had any episode of AT/AF prior to the CVE/SE.”
BackgroundAnticoagulation Therapy for Stroke Prevention in Atrial Fibrillation
Go, A. S., Hylek, E. M., Chang, Y., Phillips, K. A., Henault, L. E., Capra, A. M., Jensvold, N. G., Selby, J. V., & Singer, D. E. (2003) · JAMA · doi:10.1001/jama.290.20.2685 · Cited by 705
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–300 of 326
Beyond recurrence: redefining atrial fibrillation burden as a prognostic and therapeutic endpoint
Ballatore, A., Brookles, C. G., O'Neill, M. D., Saglietto, A., Ferrari, G. M. D., Sarkozy, A., & Anselmino, M. (2025) · Heart · doi:10.1136/heartjnl-2025-325779 · Cited by 5
Karakasis, P., Tzeis, S. E., Samaras, A., Vlachos, K. G., Pamporis, K., Theofilis, P., Tzikas, A., Antoniadis, A. P., Jaı̈s, P., & Fragakis, N. (2026) · EP Europace · doi:10.1093/europace/euag159 · Cited by 5
Simu, G. R., Tomoaia, R., Roşu, R., Guşetu, G., Puiu, M., Cismaru, G. L., Caloian, B., Terec, A., Buliga, T., Boer, A., et al. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24097710 · Cited by 5
Florentin, M., Sagris, D., Tasoudis, P., Korompoki, E., Veltkamp, R. C., D’Anna, L., Wachter, R., Milionis, H. J., & Ntaios, G. (2024) · International Journal of Stroke · doi:10.1177/17474930241292988 · Cited by 5
Orlov, M. V., Olshansky, B., Benditt, D. G., Kotler, G., McIntyre, T., Qu, F., Turkel, M., Gorev, M. V., Poghosyan, H., & Waldo, A. L. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.07.028 · Cited by 5
Field, T. S., Sposato, L. A., Hill, M. D., Healey, J. S., Andrade, J. G., & Zhou, L. W. (2022) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2022.10.017 · Cited by 5
Is there a temporal relationship between atrial fibrillation and stroke? A review
D'Lima, J., Kitisarn, R., Lim, H. S., & Thijs, V. (2024) · BMJ Neurology Open · doi:10.1136/bmjno-2023-000512 · Cited by 5
Brookles, C. G., Ponti, R. D., Russo, V., Ziacchi, M., Pelargonio, G., Casella, M., Lauretti, M., Vilotta, M., Themistoclakis, S., D’Onofrio, A., et al. (2024) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2508305 · Cited by 5
Baibars, M., Kanjwal, K., & Marine, J. E. (2014) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-013-0289-7 · Cited by 5
Shen, Y., Li, M., & Chen, M. (2022) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12969 · Cited by 4
Stroke risk in patients with device-detected atrial high-rate episodes
Erküner, Ö., Rienstra, M., Gelder, I. C. V., Schotten, U., Crijns, H. J. G. M., & LUERMANS, J. G. L. M. (2017) · Netherlands Heart Journal · doi:10.1007/s12471-017-1047-3 · Cited by 5
Left univentricular pacing for cardiac resynchronization therapy
(2017) · EP Europace · doi:10.1093/europace/euw441 · Cited by 4
Stroke Risk Stratification in Atrial Fibrillation: Bridging the Evidence Gaps
Turakhia, M. P., & Estes, N. A. M. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12891 · Cited by 5
Atrial Fibrillation and Thrombogenesis
Akar, J. G., & Marieb, M. A. (2015) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2015.05.003 · Cited by 6
Atrial fibrillation substrate mapping with emphasis on voltage-based guidance
Ciaccio, E. J., Hsia, H. H., Yarmohammadi, H., Wan, E. Y., Peters, N. S., Saluja, D. S., & BIVIANO, A. B. (2025) · World Journal of Cardiology · doi:10.4330/wjc.v17.i11.109739 · Cited by 4
Understanding atrial failure: from diagnosis to clinical implications
Alexander, B., Braunwald, E., Bayés‐Genís, A., Almufleh, A. S., Bayés‐Genís, A., & Baranchuk, A. M. (2026) · Nature Reviews Cardiology · doi:10.1038/s41569-026-01266-y · Cited by 6
Value of baseline characteristics in the risk prediction of atrial fibrillation
He, J., Liu, S., Yang, C., & Wei, Y. Q. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1068562 · Cited by 4
Uhe, T., Keilitz, J., Berrouschot, J., & Wachter, R. (2024) · TH Open · doi:10.1055/s-0044-1786015 · Cited by 4
D'Lima, J., Thijs, V., Lim, H. S., Rodrigues, T. S., & Beaudoin, A. (2024) · International Journal of Stroke · doi:10.1177/17474930241253482 · Cited by 4
Omitting transesophageal echocardiography before catheter ablation of atrial fibrillation
Maslova, V., Demming, T., Pantlik, R., Géczy, T., Falk, P., Remppis, B. A., Frank, D., & Lian, E. (2024) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-024-01825-8 · Cited by 4
Assessment of Atrial Fibrosis and Its Implications in Atrial Fibrillation and Stroke
Hanna, B., & AKOUM, N. W. (2021) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-021-00952-z · Cited by 4
Laish‐Farkash, A., Sevilya, Z., Brezinov, O. P., Fortis, L. H., & Lev, E. I. (2022) · International Journal of Cardiology Cardiovascular Risk and Prevention · doi:10.1016/j.ijcrp.2022.200155 · Cited by 4
Li, Y.-P., Chen, J., Chen, T., & Lu, W. (2023) · Scientific Reports · doi:10.1038/s41598-023-34784-7 · Cited by 4
Kim, S. E., Khawaja, M., Kim, J. A., Safavi‐Naeini, P., Pickett, J. K., Molina-Razavi, J. E., Saeed, M., Razavi, M., Rasekh, A., & Chelu, M. G. (2023) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14757 · Cited by 4
Hyman, D. A., Siebert, V., Jia, X., Alam, M., Levine, G. N., Virani, S. S., & Birnbaum, Y. (2019) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-018-06849-7 · Cited by 6
Genovesi-Ebert, A., Dini, C. S., Fusco, S. A. D., Imperoli, G., & Colivicchi, F. (2020) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000977 · Cited by 4
Embolie paradoxale : mythe ou réalité ?
Aubry, P., Demian, H., Brochet, É., & Juliard, J. (2017) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2017.10.010 · Cited by 4
Is it safe to stop oral anticoagulation after catheter ablation for atrial fibrillation?
Romero, J. E., Avendaño, R., Díaz, J. C., Taveras, J. M., Lupercio, F. A., & Biase, L. D. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2019.1550718 · Cited by 4
Yamamoto, S., Ono, H., Motoyama, H., Tachikawa, H., Tagawa, M., Akazawa, K., & Aizawa, Y. (2021) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2021.02.010 · Cited by 4
Subclinical Atrial Fibrillation, Embolic Risk, and Anticoagulant Treatment.
Gherasim, L. (2018) · Europe PMC (PubMed Central) · doi:10.26574/maedica.2018.13.4.261 · Cited by 4
Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Nazzari, H., Halperin, L. F., & Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99770-9 · Cited by 3
Artaç, İ., Karakayalı, M., Omar, T., Hamideyin, Ş., Karabağ, Y., İliş, D., & Rencüzoğulları, İ. (2023) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14749 · Cited by 3
Complex left appendage morphology is associated with Embolic Stroke of Undetermined Source
Agmon, I. N., Barnea, R., Levi, A., Murad, O., Shafir, G., Naftali, J., Schellekes, N., Shiyovich, A., Kornowski, R., Auriel, E., et al. (2024) · European Stroke Journal · doi:10.1177/23969873241246592 · Cited by 3
Tekkeşin, A. İ., Velibey, Y., Türkkan, C., Alper, A. T., Çakıllı, Y., Güvenç, T. S., Tanık, O., Kaya, A., Yıldırımtürk, Ö., Özbilgin, N., et al. (2017) · Balkan Medical Journal · doi:10.4274/balkanmedj.2016.0246 · Cited by 3
Palmisano, P., Greco, M. D., Mantica, M., Moltrasio, M., Pecora, D., Pisanò, E., Rovaris, G., & Perego, G. B. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.02.001 · Cited by 3
The Temporal Relationship Between Atrial Fibrillation and Ischemic Stroke.
Ziegler, P. (2013) · Europe PMC (PubMed Central) · doi:10.4022/jafib.738 · Cited by 3
Subclinical atrial fibrillation: when to give NAO?
Patti, G., & Sticchi, A. (2020) · European Heart Journal Supplements · doi:10.1093/eurheartj/suaa072 · Cited by 2
Implantable Cardiac Rhythm and Hemodynamic Monitors
Daly, M. G., Melton, I., & Crozier, I. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00025-0 · Cited by 3
Do supraventricular premature beats identify patients at high risk for atrial fibrillation?
Gaïta, F., & Castagno, D. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000473 · Cited by 3
Does Atrial Fibrillation Detected by Cardiac Implantable Electronic Devices Have Clinical Relevance?
Glotzer, T. V., & Ziegler, P. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2013.11.001 · Cited by 3
Gillis, A. M. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1616-0.00013-8 · Cited by 3
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.05.001 · Cited by 2
The Importance and Future of Population Screening for Atrial Fibrillation
Shin, S. Y., & Lip, G. Y. H. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.08.016 · Cited by 3
Catheter ablation of atrial fibrillation to reduce stroke risk
Schmidt, B., Bordignon, S., Fürnkranz, A., & Chun, K. R. J. (2013) · Herz · doi:10.1007/s00059-013-3776-4 · Cited by 2
Stroke Risk in Patients with Implanted Cardiac Devices
Houmsse, M., & Daoud, E. G. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.10.002 · Cited by 2
Verma, A., Cairns, J. A., Mitchell, L. B., Macle, L., Stiell, I. G., Gladstone, D. J., McMurtry, M. S., Connolly, S. J., Cox, J. L., Dorian, P., et al. (2014) · Cited by 2
Pakarinen, S., Lehto, M., RUITER, J. H., & de Voogt, W. G. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-01066-z · Cited by 2
Atrial Cardiomyopathy and Cryptogenic Stroke
Ramazanov, G. R., Ковалева, Е. А., Novikov, R. A., & Petrikov, S. S. (2022) · Russian Sklifosovsky Journal Emergency Medical Care · doi:10.23934/2223-9022-2022-11-3-493-500 · Cited by 2
Holter Monitorisation Results in Early Period of Acute Ischemic Stroke
Günaydın, S., Baştan, B., Acar, H., Balcı, B. P., Mutlu, A., & Çokar, Ö. (2016) · Nöro Psikiyatri Arşivi · doi:10.5152/npa.2016.17012 · Cited by 2
Left Atrial Appendage Closure Device in Atrial Fibrillation
GIUDICI, M. C., & Bhave, P. D. (2017) · Cardiology Clinics · doi:10.1016/j.ccl.2016.12.011 · Cited by 2
When is Device-Detected Atrial Fibrillation Actionable?
Wasserlauf, J., & PASSMAN, R. S. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2017.11.007 · Cited by 3
Özcan, E. E. (2018) · The Anatolian Journal of Cardiology · doi:10.14744/anatoljcardiol.2017.8223 · Cited by 2
Atrial Fibrillation and the Role of Thumb ECGs
Magnusson, P., Samuelsson, M., Pergolizzi, J. V., Annabi, H. M., & LeQuang, J. A. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.83660 · Cited by 2
Atrial Tachyarrhythmias and Stroke: Temporal Relationship and Stroke Subtypes
Blackie, H., Thijs, V., Churilov, L. P., Han, H., Lin, T., Teh, A. W., Jones, E. F., Horrigan, M., Farouque, O., & Lim, H. S. (2022) · Cerebrovascular Diseases · doi:10.1159/000526088 · Cited by 3
When to set anticoagulant therapy in asymptomatic AF? looking for a cut-off duration
Rossini, R., & Peirone, A. (2022) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suac086 · Cited by 2
Saglietto, A., Ballatore, A., Brookles, C. G., Xhakupi, H., Ferrari, G. M. D., & Anselmino, M. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1289372 · Cited by 2
Yang, Y., Xu, F., Tong, J., Cai, L., Jiang, W., Sheng, X., Pan, Y., Jiang, J., Zhang, J., Jiang, D., et al. (2018) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-018-6807-9 · Cited by 3
Wyse, D. G. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.08.006 · Cited by 2
Birnie, D. H., Smith, E. E., & Verma, A. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14056 · Cited by 2
Berti, S. L., Caterina, A. R. D., & Berger, R. D. (2022) · JACC Case Reports · doi:10.1016/j.jaccas.2022.04.015 · Cited by 2
Challenges and Opportunities for Atrial Fibrillation Management
Cai, M., & Heijman, J. (2025) · Cardiology Discovery · doi:10.1097/cd9.0000000000000155 · Cited by 2
Predictors of Stroke in Patients With Atrial Fibrillation: A Retrospective Study
Soor, D., Majeed, K., Bukhari, Z. B., Zeeshan, A., Soe, K. N., Azmat, M., & Saeed, A. (2026) · Cureus · doi:10.7759/cureus.104243 · Cited by 1
Home Screening for Detecting Subclinical Atrial Fibrillation.
Ricci, R. P., & Glotzer, T. V. (2015) · PubMed Central · doi:10.4022/jafib.1326 · Cited by 1
Cardiac Arrhythmia following Stroke
Kallmünzer, B., & Schwab, S. (2017) · Neurology International Open · doi:10.1055/s-0043-102263 · Cited by 1
Herzrhythmusstörungen nach Schlaganfall
Kallmünzer, B., & Schwab, S. (2017) · Aktuelle Neurologie · doi:10.1055/s-0043-101374 · Cited by 1
Caheter ablation for atrial fibrillation in prevention of stroke
Fiala, M. (2017) · Intervenční a akutní kardiologie · doi:10.36290/kar.2017.011 · Cited by 1
OBSOLETE: Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99770-8 · Cited by 1
Approach to device-detected subclinical atrial fibrillation
van Zyl, M., McLeod, C. J., & Gersh, B. J. (2017) · SA Heart · doi:10.24170/14-2-2497 · Cited by 1
Shurrab, M., Ko, D. T., Atoui, R., Kostiw, K., & Henderson, M. A. (2021) · The Heart Surgery Forum · doi:10.1532/hsf.3857 · Cited by 1
Prise en charge de l'AVC cryptogénique : où en sommes-nous ?
Aubry, P., Hamidouche, F., Alqudwa, A., Naoum-Nehme, A., Maiga, B., Camara, N., Manchon, É., & Poulos, N. (2021) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2021.10.006 · Cited by 1
The Year in Review of Clinical Cardiac Electrophysiology
Marcus, G. M., Keung, E. C., & Scheinman, M. M. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.09.050 · Cited by 1
Notaristefano, F., & Cavallini, C. (2022) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2022.02.004 · Cited by 1
Kitamura, A., Ogawa, N., Nakamura, R., Sugiyama, S., Tamura, R., Tsukamoto, T., Yabata, H., Kobashi, S., Tamaki, Y., Shitara, S., et al. (2025) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2025.108470 · Cited by 2
Subclinical atrial fibrillation: A new entity and what it means?
Ott, P. (2016) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2016.07.031 · Cited by 1
Gillis, A. M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00013-4 · Cited by 1
Merino, J. L., & Tamargo, J. L. (2021) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-021-07246-3 · Cited by 1
A Fresh Perspective on Atrial Fibrillation ∗
Curtis, J. P., & Akar, J. G. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.06.019 · Cited by 1
Atrial fibrillation: a mechanism or just a bystander?
Smit, M. D., & Gelder, I. C. V. (2017) · EP Europace · doi:10.1093/europace/eux040 · Cited by 1
Atrial Fibrillation Already Known Versus Detected After Stroke: Same Battle?
Guénancia, C., & Béjot, Y. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.124.036138 · Cited by 1
Atrial Fibrillation and Heart Failure in the Aging Population
Kazemian, P., & Jugdutt, B. I. (2014) · Springer eBooks · doi:10.1007/978-1-4939-0268-2_5
Cardiac Resynchronization and Atrial Fibrillation: What's New?
Barold, S. S., & Herweg, B. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03416.x
How early is early enough to prevent stroke in atrial fibrillation?
Guo, Y., Lip, G. Y. H., & Apostolakis, S. Z. (2012) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.12.36
Kudenchuk, P. J. (2015) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-015-1181-y
Walters, T. E., & Kalman, J. M. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12446
Asymptomatic Atrial Fibrillation After Cryptogenetic Stroke
Raviele, A. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.002835
Left Atrial Appendage Closure Device in Atrial Fibrillation
GIUDICI, M. C., & Bhave, P. D. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2015.05.004
Should Atrial Fibrillation Burden Be A Feature to Guide Thromboembolism Prophylaxis?
Sachdev, M., & Daoud, E. G. (2012) · Europe PMC (PubMed Central) · doi:10.4022/jafib.530
Duração dos Episódios de Fibrilhação Auricular e Implicações no Risco Tromboembólico
Neves, D., Cunha, P. S., & Oliveira, M. (2015) · Acta Médica Portuguesa · doi:10.20344/amp.6359
Healey, J. S., Martin, J. L., Duncan, A., Connolly, S. J., Ha, A. H., Morillo, C. A., Nair, G. M., Eikelboom, J. W., & Dokainish, H. (2013)
Transcatheter left atrial appendage occlusion: patient selection and perspectives
Wojciech, W. (2016) · Research Reports in Clinical Cardiology · doi:10.2147/rrcc.s83325
New insights into protecting the brain from the heart
Krieger, D. W. (2016) · Future Neurology · doi:10.2217/fnl-2016-0015
Atrial Fibrillation and the Risk of Stroke
Patel, P. J., & Deo, R. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003367
Fibrilación auricular paroxística en ataque cerebro-vascular criptogénico
Torres-Zafra, J. (2016) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2016.10.020
Fibrilación auricular en pacientes con dispositivos cardiacos electrónicos implantables
Akerström, F. O., Pachón, M., Puchol, A., Pérez, A. S., & Arias, M. A. (2016) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(16)30014-0
Is antithrombotic therapy necessary for short self-limiting episodes of atrial fibrillation?
Stazi, D. F. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000466
Cardiac Electrophysiology in Stroke Investigation
Santucci, P. A. (2017) · Primer on Cerebrovascular Diseases · doi:10.1016/b978-0-12-803058-5.00128-4
Heuzey, J. L. (2017) · La Presse Médicale · doi:10.1016/j.lpm.2017.06.013
Can Implantable Cardiac Devices Be Used to Lower Risk of Stroke?
Wasserlauf, J., & PASSMAN, R. S. (2017) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-017-0554-5
Ozcan, E., Kudaiberdieva, G., & Görenek, B. (2017) · Heart Vessels and Transplantation · doi:10.24969/hvt.2017.27
Metadata
- Authors
- Daoud, E. G., Glotzer, T. V., Wyse, D. G., Ezekowitz, M. D., Hilker, C., Koehler, J., & Ziegler, P. D.
- Affiliations
- The Ohio State University Wexner Medical Center (US)
- Hackensack University Medical Center (US)
- Libin Cardiovascular Institute of Alberta (CA)
- Lankenau Institute for Medical Research (US)
- Medtronic (United States) (US)
- Corresponding author
- Daoud, Emile G.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2011-09
- Volume
- 8
- Issue
- 9
- Pages
- 1416-1423
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2020006237
- Cited by
- 326
- References
- 33
- Citations by year
- 2026: 8 · 2025: 10 · 2024: 20 · 2023: 18 · 2022: 20 · 2021: 28 · 2020: 20 · 2019: 19 · 2018: 31 · 2017: 38 · 2016: 39 · 2015: 26 · 2014: 24 · 2013: 10 · 2012: 11
- FWCI
- 10.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Heart Rhythm (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Medtronic
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial tachyarrhythmia, atrial fibrillation, atrial tachycardia, cerebrovascular events, systemic embolism, stroke, temporal relations, cardiac implantable electronic devices, device monitoring, cardiac embolism
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Cardiac Pacing, Artificial, Embolism, Female, Humans, Male, Middle Aged, Product Surveillance, Postmarketing, Prospective Studies, Tachycardia, Ectopic Atrial, Information Storage and Retrieval, Defibrillators, Implantable, Brain Infarction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review