The DOI matches its Crossref record.
Localizing the critical isthmus of postinfarct ventricular tachycardia: The value of pace-mapping during sinus rhythm
Abstract
BACKGROUND Most postinfarct ventricular tachycardias (VTs) are sustained by a reentrant mechanism. The "protected isthmus" of the reentrant circuit is critical for the maintenance of VTs and the target for catheter ablation. Various techniques based on conventional electrophysiology and/or detailed three-dimensional (3D) reconstruction of the VT circuit are used to unmask this isthmus. OBJECTIVE The purpose of this study was to assess pace-maps (PMs) to identify postinfarct VT isthmuses. We hypothesized that an abrupt change in paced QRS morphology may be used to identify a VT isthmus and be targeted for successful ablation. METHODS High-density 3D PMs were matched to the subsequent 3D endocardial reentrant VT activation mapping in 10 patients (8 men; age 70.7 ± 10.8 years) who underwent successful postinfarct VT ablation. At each pacing site in a given patient, the 12-lead ECG recorded during pacing was compared to that of VT, with the resulting matching percentage (up to 100% for perfect matches) allocated to this point to generate color-coded PMs. RESULTS With respect to VT isthmuses, the best percentages of matching were found in the exit zones and isthmus exit part (89% ± 8% and 84% ± 7%, respectively) and the poorest adjacent to scar border in the outer entrance zones (23% ± 28%), in the entrance zones (39% ± 34%), and in the entrance part of the isthmus (32% ± 26%). The color-coded sequence (from the best to the poorest matching sites) on the PMs revealed figure-of-eight pictures matching the VT activation time maps and identifying VT isthmuses. CONCLUSION Pace-mapping is useful for unmasking VT isthmuses in patients with well-tolerated postinfarct endocardial reentrant VTs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationArrhythmogenic and metabolic remodelling of failing human heart
Gloschat, C. R., Koppel, A. C., Aras, K. K., Brennan, J. A., Holzem, K. M., & Efimov, I. R. (2016) · The Journal of Physiology · doi:10.1113/jp271992 · Cited by 23
Metadata
- Authors
- de Chillou, C., Groben, L., Magnin-Poull, I., Andronache, M., Abbas, M. M., Zhang, N., Abdelaal, A., Ammar, S., Sellal, J.-M., Schwartz, J., Brembilla-Perrot, B., Aliot, E., & Marchlinski, F. E.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2014-02
- Volume
- 11
- Issue
- 2
- Pages
- 175-181
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2036287524
- Cited by
- 178
- References
- 0
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Localizing the critical isthmus of postinfarct ventricular tachycardia: The value of pace-mapping during sinus rhythm. https://app.cochat.ai/papers/10.1016/j.hrthm.2013.10.042
- The paper
- de Chillou, C., Groben, L., Magnin-Poull, I., Andronache, M., Abbas, M. M., Zhang, N., Abdelaal, A., Ammar, S., Sellal, J.-M., Schwartz, J., Brembilla-Perrot, B., Aliot, E., & Marchlinski, F. E. (2014). Localizing the critical isthmus of postinfarct ventricular tachycardia: The value of pace-mapping during sinus rhythm. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2013.10.042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.