The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cardiac magnetic resonance–aided scar dechanneling: Influence on acute and long-term outcomes
Open accessAbstract
BACKGROUND: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) provides tissue characterization of ventricular myocardium and scar that can be depicted as pixel signal intensity (PSI) maps. OBJECTIVE: To assess the possible benefit of guiding the ventricular tachycardia (VT) substrate mapping by integrating these PSI maps into the navigation system. METHODS: In total, 159 consecutive patients (66 ± 11 years old, 151 men [95%]) with scar-related left ventricular (LV) VT were included. VT substrate ablation used the scar dechanneling technique. A CMR-aided ablation using the PSI maps was performed in 54 patients (34%). Procedural data as well as acute and long-term outcomes were compared with those of the remaining 105 patients (66%). RESULTS: Mean procedure duration and fluoroscopy time were 229 ± 67 minutes and 20 ± 9 minutes, respectively, without significant differences between groups. Both the number of radiofrequency (RF) applications and RF delivery time were lower in the CMR-aided group (28 ± 18 applications vs 36 ± 18 applications, P = .037, and 19 ± 12 minutes vs 27 ± 16 minutes, P = .009, respectively). After substrate ablation, monomorphic VT inducibility was lower in the CMR-aided than in the control group (17 [32%] vs 53 [51%] patients, P = .022). After a mean follow-up period of 20 ± 19 months, patients from the CMR-aided group had a lower recurrence rate than those in the control group (10 patients [18.5%] vs 46 patients [43.8%], respectively, P = .002; log-rank P = .017). Multivariate analysis found that CMR-aided ablation (hazard ratio, 0.48 [95% Confirdence Interval (CI) 0.24-0.96], P = .037) was an independent predictor of recurrences. CONCLUSION: CMR-aided scar dechanneling is associated with a lower need for RF delivery, higher noninducibility rates after substrate ablation, and a higher VT-recurrence-free survival.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citation
Metadata
- Authors
- Andreu, D., Penela, D., Acosta, J., Fernández-Armenta, J., Perea, R. J., Soto-Iglesias, D., de Caralt, T. M., Ortiz-Perez, J. T., Prat-González, S., Borràs, R., Guasch, E., Tolosana, J. M., Mont, L., & Berruezo, A.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2017-08
- Volume
- 14
- Issue
- 8
- Pages
- 1121-1128
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2741534573
- Cited by
- 198
- References
- 1
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.