Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 172

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Prospective blinded evaluation of a novel sensing methodology designed to reduce inappropriate shocks by the subcutaneous implantable cardioverter-defibrillator

Open access
Theuns, Dominic A.M.J., Brouwer, Tom F., Jones, Paul W., Allavatam, Venugopal, Donnelley, Steven, Auricchio, Angelo, Knops, Reinoud E., Burke, Martin C. · 2018 · Heart Rhythm

Abstract

BACKGROUND: Most inappropriate shocks from the subcutaneous implantable cardioverter-defibrillator (S-ICD) are caused by cardiac oversensing. A novel sensing methodology, SMART Pass (SP; Boston Scientific Corporation, Natick, MA), aims to reduce cardiac oversensing. OBJECTIVE: The purpose of this study was to evaluate the effect of SP on shocks in ambulatory patients with S-ICD. METHODS: Patients implanted in 2015-2016 and enrolled in a remote patient monitoring system were included and followed for 1 year. Shocks were adjudicated by 3 independent blinded reviewers as appropriate or inappropriate. Shock incidence was calculated for patients with SP programmed enabled or disabled at implantation, censoring patients when SP programming changed or at the last transmission. The SP setting (enabled vs disabled) was modeled as a time-dependent Cox regression variable. RESULTS: The cohort consisted of 1984 patients, and a total of 880 shocks were adjudicated. At implantation, SP was enabled in 655 patients (33%) and disabled in 1329 patients (67%). SP reduced the risk for the first inappropriate shock by 50% (P < .001) and the risk for all inappropriate shocks by 68% (P < .001) in multivariate analysis adjusted for age and device programming. The incidence of inappropriate shocks was 4.3% in the SP enabled arm vs 9.7% in the SP disabled arm. The incidence of appropriate shocks was similar (5.2% vs 6.6%; P = .18) along with the time to treat the first appropriate shock (17.4 seconds vs 16.7 seconds; P = .92) for SP enabled vs disabled, respectively. CONCLUSION: This prospective blinded evaluation of the SP filter demonstrates that enabling the SP filter results in a significant reduction of inappropriate shocks by the S-ICD without a negative effect on appropriate shocks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2018.05.011

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 172

Metadata

Authors
Theuns, D. A. M. J., Brouwer, T. F., Jones, P. W., Allavatam, V., Donnelley, S., Auricchio, A., Knops, R. E., & Burke, M. C.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2018-10
Volume
15
Issue
10
Pages
1515-1522
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2801177091
Cited by
172
References
1
FWCI
14.45
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective blinded evaluation of a novel sensing methodology designed to reduce inappropriate shocks by the subcutaneous implantable cardioverter-defibrillator. https://app.cochat.ai/papers/10.1016/j.hrthm.2018.05.011
The paper
Theuns, D. A. M. J., Brouwer, T. F., Jones, P. W., Allavatam, V., Donnelley, S., Auricchio, A., Knops, R. E., & Burke, M. C. (2018). Prospective blinded evaluation of a novel sensing methodology designed to reduce inappropriate shocks by the subcutaneous implantable cardioverter-defibrillator. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2018.05.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.