The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Left bundle branch pacing for symptomatic bradycardia: Implant success rate, safety, and pacing characteristics
Open accessAbstract
BACKGROUND In patients with or without left bundle branch block, left bundle branch pacing (LBBP) can produce near normalization of QRS duration (QRSd). This has recently emerged as an alternative technique to His bundle pacing. OBJECTIVES The purpose of this study was to characterize a novel approach for LBBP in patients with a bradycardia indication for pacing and to assess implant success rate and midterm safety. METHODS Patients with bradycardia indications for pacing underwent LBBP by a trans-ventricular-septal method in the basal ventricular septum. Procedural success, pacing parameters, and complications were assessed at implantation and at 3 months follow-up. RESULTS This prospective study evaluated 87 patients (sinus node dysfunction 68%; atrioventricular conduction disease 32%) undergoing pacemaker implantation. LBBP implantation succeeded in 70 patients (80.5%) and the remaining 17 patients received right ventricular septal pacing. The procedure time of LBBP implantation was 18.0 ± 8.8 minutes with a fluoroscopic exposure time of 3.9 ± 2.7 minutes. LBBP produced narrower electrocardiographic QRSd than did right ventricular septal pacing (113.2 ± 9.9 ms vs 144.4 ± 12.8 ms; P < .001). There were no major implantation-related complications. The pacing threshold was low (0.76 ± 0.22 V at implantation and 0.71 ± 0.23 V at 3 months), with no loss of capture or lead dislodgment observed. CONCLUSION This study demonstrates that in patients with standard bradycardia pacing indications, LBBP results in QRSd < 120 ms in most patients and can be performed successfully and safely in the majority of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., & Ellenbogen, K. A. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.09.013 · Cited by 736
Vijayaraman, P., Chung, M. K., Dandamudi, G., Upadhyay, G. A., Krishnan, K., Crossley, G., Bova Campbell, K., Lee, B. K., Refaat, M. M., Saksena, S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.017 · Cited by 350
Electrophysiologic Insights Into Site of Atrioventricular Block
Vijayaraman, P., Naperkowski, A., Ellenbogen, K. A., & Dandamudi, G. (2015) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2015.09.012 · Cited by 173
Cited by
Randomized Trial of Left Bundle Branch vs Biventricular Pacing for Cardiac Resynchronization Therapy
Wang, Y., Zhu, H., Hou, X., Wang, Z., Zou, F., Qian, Z., Wei, Y., Wang, X., Zhang, L., Li, X., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.07.019 · Cited by 370
Self-citation
Metadata
- Authors
- Li, Y., Chen, K., Dai, Y., Li, C., Sun, Q., Chen, R., Gold, M. R., & Zhang, S.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 16
- Issue
- 12
- Pages
- 1758-1765
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2946056554
- Cited by
- 205
- References
- 3
- FWCI
- 19.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left bundle branch pacing for symptomatic bradycardia: Implant success rate, safety, and pacing characteristics. https://app.cochat.ai/papers/10.1016/j.hrthm.2019.05.014
- The paper
- Li, Y., Chen, K., Dai, Y., Li, C., Sun, Q., Chen, R., Gold, M. R., & Zhang, S. (2019). Left bundle branch pacing for symptomatic bradycardia: Implant success rate, safety, and pacing characteristics. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2019.05.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.