Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Left bundle branch–optimized cardiac resynchronization therapy (LOT-CRT): Results from an international LBBAP collaborative study group

Open access
Jastrzębski, Marek, Moskal, Paweł, Huybrechts, Wim, Curila, Karol, Sreekumar, Praveen, Rademakers, Leonard M., Ponnusamy, Shunmuga Sundaram, Herweg, Bengt, Sharma, Parikshit S., Bednarek, Agnieszka, Rajzer, Marek, Vijayaraman, Pugazhendhi · 2022 · Heart Rhythm

Abstract

BACKGROUND Cardiac resynchronization therapy (CRT) based on the conventional biventricular pacing (BiV-CRT) technique sometimes results in broad QRS and suboptimal response. OBJECTIVE We aimed to assess the feasibility and outcomes of CRT based on left bundle branch area pacing (LBBAP, in lieu of right ventricular lead) combined with coronary venous (CV) left ventricular pacing in an international multicenter study. METHODS LBBAP-optimized CRT (LOT-CRT) was attempted in non-consecutive patients with CRT indications. Addition of LBBA (or CV) lead was at the discretion of the implanting physician, guided by suboptimal paced QRS and/or on clinical grounds. RESULTS LOT-CRT was successful in 91/112 (81%) patients. Baseline characteristics: age 70±11 years, female 20%, LVEF 28.7±9.8%, LVEDD 62±9 mm, NT-pro-BNP 5821±8193 pg/ml, LBBB 42%, NIVCD 22%, RVP 23%, RBBB 12%. Procedure characteristics: mean fluoroscopy 27.3±22 min, LBBAP capture threshold 0.8±0.5V @0.5ms, R-wave amplitude 10 mV. LOT-CRT resulted in significantly greater narrowing of QRS from 182±25 ms at baseline to 144±22 ms (p<0.0001), compared to BiV-CRT (170±30 ms, p < 0.0001) and LBBAP (162±23 ms, p < 0.0001). At follow-up of ≥ 3 months, EF improved to 37±12%, LVEDD decreased to 59±9 mm, NT-pro-BNP decreased to 2514±3537 pg/ml, pacing parameters were stable, and clinical improvement was noted in 76% of patients (NYHA class 2.9 vs 1.9). CONCLUSION LOT-CRT is feasible, safe and provides greater electrical resynchronization compared to BiV-CRT and could be an alternative option, especially when only suboptimal electrical resynchronization is obtained with BiV-CRT. Randomized, controlled trials comparing LOT-CRT and BiV-CRT are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2021.07.057

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 243

Metadata

Authors
Jastrzębski, M., Moskal, P., Huybrechts, W., Curila, K., Sreekumar, P., Rademakers, L. M., Ponnusamy, S. S., Herweg, B., Sharma, P. S., Bednarek, A., Rajzer, M., & Vijayaraman, P.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2022-01
Volume
19
Issue
1
Pages
13-21
ISSN
1547-5271 (ISSN-L)
OpenAlex
W3190185020
Cited by
243
References
2
FWCI
25.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left bundle branch–optimized cardiac resynchronization therapy (LOT-CRT): Results from an international LBBAP collaborative study group. https://app.cochat.ai/papers/10.1016/j.hrthm.2021.07.057
The paper
Jastrzębski, M., Moskal, P., Huybrechts, W., Curila, K., Sreekumar, P., Rademakers, L. M., Ponnusamy, S. S., Herweg, B., Sharma, P. S., Bednarek, A., Rajzer, M., & Vijayaraman, P. (2022). Left bundle branch–optimized cardiac resynchronization therapy (LOT-CRT): Results from an international LBBAP collaborative study group. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2021.07.057

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.