Cited by 60Silk-based biomaterials and applicationsElectrospun Nanofibers in Biomedical ApplicationsBone Tissue Engineering Materials

Freeze-gelled silk fibroin protein scaffolds for potential applications in soft tissue engineering

Bhardwaj, Nandana, Chakraborty, Sagar, Kundu, Subhas C.·2011·International Journal of Biological Macromolecules

Abstract

Recently tissue engineering has escalated much interest in biomedical and biotechnological applications. In this regard, exploration of new and suitable biomaterials is needed. Silk fibroin protein is used as one of the most preferable biomaterials for fabrication of scaffolds and several new techniques are being adopted to fabricate silk scaffolds with greater ease, efficiency and perfection. In this study, a freeze gelation technique is used for fabrication of silk fibroin protein 3D scaffolds, which is both time and energy efficient as compared to the conventional freeze drying technique. The fabricated silk fibroin freeze-gelled scaffolds are evaluated micro structurally for morphology with scanning electron microscopy which reveals relatively homogeneous pore structure and good interconnectivity. The pore sizes and porosity of these scaffolds ranges between 60-110μm and 90-95%, respectively. Mechanical test shows that the compressive strength of the scaffolds is in the range of 20-40kPa. The applicability to cell culture of the freeze gelled scaffolds has been examined with human keratinocytes HaCat cells which show the good cell viability and proliferation of cells after 5 days of culture suggesting the cytocompatibility. The freeze-gelled 3D scaffolds show comparable results with the conventionally prepared freeze dried 3D scaffolds. Thus, this technique may be used as an alternative method for 3D scaffolds preparation and may also be utilized for tissue engineering applications.

Integrity signals

Registry

Crossref · 10.1016/j.ijbiomac.2011.04.013

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Changing the silk fibroin solution's temperature, concentration, Ca2+ concentration, or ultrasound frequency under the same conditions can change the silk fibroin gelation process.

    “If the silk fibroin solution’s temperature, concentration, Ca2+ concentration, or ultrasound frequency is changed under the same conditions, it can change the silk fibroin gelation process [77,78].”

Cited by

Sorted by citations

Authors
Bhardwaj, N., Chakraborty, S., & Kundu, S. C.
Affiliations
Indian Institute of Technology Kharagpur (IN)
Corresponding author
Kundu, Subhas C.
Venue
International Journal of Biological Macromolecules
Publisher
Elsevier BV
Published
2011-10
Volume
49
Issue
3
Pages
260-267
ISSN
0141-8130 (ISSN-L)
OpenAlex
W2078052046
Cited by
60
References
0
Citations by year
2026: 1 · 2025: 4 · 2024: 3 · 2023: 2 · 2022: 4 · 2021: 2 · 2020: 3 · 2019: 7 · 2018: 5 · 2017: 7 · 2016: 3 · 2015: 7 · 2014: 6 · 2013: 5 · 2012: 1
FWCI
1.57
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Biological Macromolecules (publishedVersion)
  • PubMed (publishedVersion)
Funders
Department of Science and Technology, Ministry of Science and Technology, India
Topics
  • Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
silk fibroin, freeze-gelation, 3D scaffolds, soft tissue engineering, biomaterials, pore structure, porosity, compressive strength, cytocompatibility, HaCaT keratinocytes, freeze-dried scaffolds
MeSH terms
Animals, Biocompatible Materials, Biotechnology, Cell Line, Cell Survival, Fibroins, Freezing, Gels, Humans, Materials Testing, Surface Properties, Time Factors, Porosity, Tissue Engineering, Tissue Scaffolds, Mechanical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review