Cited by 62Hydrogels: synthesis, properties, applicationsElectrospun Nanofibers in Biomedical ApplicationsBone Tissue Engineering Materials

Highly porous of hydroxyethyl cellulose biocomposite scaffolds for tissue engineering

Zulkifli, Farah Hanani, Hussain, Fathima Shahitha Jahir, Harun, W.S.W., Yusoff, Mashitah M.·2019·International Journal of Biological Macromolecules

Abstract

This study is focusing to develop a porous biocompatible scaffold using hydroxyethyl cellulose (HEC) and poly (vinyl alcohol) (PVA) with improved cellular adhesion profiles and stability. The combination of HEC and PVA were synthesized using freeze-drying technique and characterized using SEM, ATR-FTIR, TGA, DSC, and UTM. Pore size of HEC/PVA (2-40 μm) scaffolds showed diameter in a range of both pure HEC (2-20 μm) and PVA (14-70 μm). All scaffolds revealed high porosity above 85%. The water uptake of HEC was controlled by PVA cooperation in the polymer matrix. After 7 days, all blended scaffolds showed low degradation rate with the increased of PVA composition. The FTIR and TGA results explicit possible chemical interactions and mass loss of blended scaffolds, respectively. The T g values of DSC curved in range of HEC and PVA represented the miscibility of HEC/PVA blend polymers. Higher Young's modulus was obtained with the increasing of HEC value. Cell-scaffolds interaction demonstrated that human fibroblast (hFB) cells adhered to polymer matrices with better cell proliferation observed after 7 days of cultivation. These results suggested that biocompatible of HEC/PVA scaffolds fabricated by freeze-drying method might be suitable for skin tissue engineering applications.

Integrity signals

Registry

Crossref · 10.1016/j.ijbiomac.2018.10.156

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PVA-based scaffold design with >85% is favorable for tissue engineering applications.

    “PVA-based scaffold design with >85% is favorable for the TE applications [14].”
  • The rate of polymer degradation can be modulated by adjusting the composition, molecular weight, and end groups in the polymer, as well as by the composition and geometry of the device.

    “The rate of degradation can be modulated by adjusting the composition, molecular weight, and end groups in the polymer, as well as by the composition and geometry of the device [14].”

Cited by

Sorted by citations

Authors
Zulkifli, F. H., Hussain, F. S. J., Harun, W. S. W., & Yusoff, M. M.
Affiliations
Universiti Malaysia Pahang Al-Sultan Abdullah (MY)
Corresponding author
Zulkifli, Farah Hanani
Venue
International Journal of Biological Macromolecules
Publisher
Elsevier BV
Published
2019-02
Volume
122
Pages
562-571
ISSN
0141-8130 (ISSN-L)
OpenAlex
W2897075578
Cited by
62
References
0
Citations by year
2026: 5 · 2025: 5 · 2024: 7 · 2023: 12 · 2022: 10 · 2021: 7 · 2020: 12 · 2019: 4
FWCI
2.17
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Biological Macromolecules (publishedVersion)
  • PubMed (publishedVersion)
  • UMP Institutional Repository (Universiti Malaysia Pahang) (acceptedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
hydroxyethyl cellulose, polyvinyl alcohol, porous scaffolds, freeze-drying, polymer blends, porosity, water absorption, degradation rate, thermal stability, glass transition, mechanical properties, human fibroblasts, cell adhesion, skin tissue engineering, biocomposites
MeSH terms
Biocompatible Materials, Cellulose, Fibroblasts, Humans, Porosity, Tissue Engineering, Tissue Scaffolds, Mechanical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review