Early versus delayed implantation of a loop recorder in patients with unexplained syncope–effects on care pathway and diagnostic yield
Abstract
Background This study looked to assess the care pathway and diagnostic yield in patients who received an implantable loop recorder (ILR) after an "initial phase of the diagnostic work-up" (initial work-up) or after a "full evaluation" of unexplained syncope.Methods and results Physicians classified the timing of an ILR implant in 514 patients as either following an "initial work-up" (n=128; 25%) or "full evaluation" (n=386; 75%). Patients with an "initial work-up" underwent a median (IQ range) of 8 (6-14) tests prior to ILR implant compared to 14 (10-21) tests after "full evaluation" (p<0.0001). Hospitalization and injury before implant were less common in patients with an "initial work-up": 53 vs. 75%, p<0001, and 23% vs. 39%, p<0.001, as were visits to specialists, e.g. neurologist, 32% vs. 50%, p<0.001. At one year after implant, the syncope recurrence rate was 32% in the initial work-up group and 36% in the full evaluation group, and the incidence of recurrences with an ILR-guided diagnosis was 52% and 75% respectively. Diagnoses were cardiac in 90% after "initial work-up" vs. 79% after "full evaluation".Conclusions Patients who only underwent an "initial work-up" had fewer investigations and a lower incidence of injury or hospitalization. The diagnostic yield from the ILR was high in both groups. Patients in both groups underwent more investigations than suggested in the ESC guidelines and could have benefitted from limiting the initial evaluation before an ILR is implanted.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In patients with recurrent syncope of uncertain origin, absence of high-risk criteria and structural heart disease, and in suspected reflex syncope, an asystolic pause was present during syncope in about 50% of patients.
“Similar findings were subsequently observed with ILR use expanded in an early phase of evaluation in patients with recurrent syncope of uncertain origin, in the absence of highrisk criteria and structural heart disease, 176,180-183 and in suspected reflex syncope. 184-186 In particular, an asystolic pause was present during syncope in about 50% of these patients.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [181]
The citation lists haven’t been fetched yet
References 22 · Cited by 21
- Authors
- Linker, N. J., Voulgaraki, D., Garutti, C., Rieger, G., & Edvardsson, N.
- Affiliations
- James Cook University Hospital (GB)
- Medtronic (Netherlands) (NL)
- Sahlgrenska University Hospital (SE)
- Corresponding author
- Linker, Nicholas J.
- ORCID
- Linker, Nicholas J.
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 170
- Issue
- 2
- Pages
- 146-151
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W1996230119
- Cited by
- 21
- References
- 22
- Citations by year
- 2024: 1 · 2021: 2 · 2019: 4 · 2018: 4 · 2017: 7 · 2016: 2 · 2015: 1
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Medtronic
- Topics
- Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- unexplained syncope, implantable loop recorder, implantation timing, diagnostic yield, care pathways, syncope recurrence, cardiac syncope, diagnostic workup, hospitalization, injuries
- MeSH terms
- Adult, Aged, Electrodes, Implanted, Female, Humans, Male, Middle Aged, Recurrence, Registries, Syncope, Electrocardiography, Ambulatory, Incidence, Practice Guidelines as Topic, Critical Pathways, Early Diagnosis, Kaplan-Meier Estimate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review