Robust sensor fault detection and isolation scheme for interconnected smart power systems in presence of RER and EVs using unknown input observer

Haes Alhelou, H., Hamedani Golshan, M.E., Askari-Marnani, J. · 2018 · International Journal of Electrical Power & Energy Systems

Abstract

Abstract Correct measurement of variables used in frequency control of power system is crucial for power system operation, stability, and security. Once sensor fault is occurred in power system, the faulty sensor should be instantly isolated. To this end, a model-based fault detection and isolation (FDI) technique is adopted in this paper. The proposed sensor FDI scheme for complex power systems is built based on unknown input observer (UIO) which is robust for systems with unknown inputs. The load fluctuation and output power variation of renewable energy resources are modeled as unknown inputs of power systems. To show the effectiveness of the proposed schemes in case of future smart grids, the studied power system is developed to combine both electric vehicles (EVs) and high penetration level of renewable energy resources. The simulation scenarios are carried out for an eleven-order dynamical multi-area smart power system. The robustness of using UIO to detect and isolate sensor faults in power system is proved by several simulation scenarios. Likewise, the simulation results show that isolation of faulty sensors can be guaranteed by proper selection of the measured variables in the state space model of the studied system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijepes.2018.02.013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Haes Alhelou, H., Hamedani Golshan, M. E., & Askari-Marnani, J.
Venue
International Journal of Electrical Power & Energy Systems
Publisher
Elsevier BV
Published
2018-07
Volume
99
Pages
682-694
ISSN
0142-0615 (ISSN-L)
OpenAlex
W2792899709
Cited by
175
References
0
FWCI
12.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.