CoChat

A fault-tolerant grid-forming converter applied to AC microgrids

Antunes, Hélio Marcos André, Silva, Sidelmo Magalhães, Brandao, Danilo Iglesias, Machado, Alysson Augusto Pereira, Ferreira, Reginaldo Vagner · 2020 · International Journal of Electrical Power & Energy Systems

The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index, and 1 are not checked yet.

Abstract

A crucial converter for the islanded operation of AC microgrids is the grid-forming converter. This central converter supplies electrical loads, and assures the distributed generators operation, since the malfunctioning of grid-forming converter can jeopardize the whole microgrid. This paper proposes a bidirectional grid-forming converter with a fault-tolerant functionality applied to islanded AC microgrids using a centralized control architecture. The converter is based on a delta connection of three single-phase voltage source inverters (VSIs) using an H-bridge topology for three-phase three- or four-wire systems. For this latter case, a zigzag transformer is used to provide the neutral conductor for the system. In addition to establishing voltage and frequency references for the microgrid, the converter is capable of changing its configuration from delta to open-delta, and vice-versa, in a smooth mode and without interrupting the microgrid operation. Thus, in case of failure of one of the grid-forming VSIs, the system can keep supplying the microgrid. A control strategy is developed to allow a stable operation in all operating modes. Experimental results are presented with a converter prototype to validate the proposed topology, control and mode of connection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijepes.2020.106072

Cites

30 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Research works printed but not linked: 3

  1. Silva SM. Three-phase dynamic voltage compensator with reduced switch-count and absence of energy storage system 2003. p. 970–5. · doi:10.1109/ias.2003.1257656
  2. Bollen, 2006, vol. 30
  3. Buso, 2006, vol. 1

Cited by

Metadata

Authors
Antunes, H. M. A., Silva, S. M., Brandao, D. I., Machado, A. A. P., & Ferreira, R. V.
Affiliations
  • Universidade Federal do Espírito Santo (BR)
  • Instituto Federal do Espírito Santo (BR)
  • Instituto Federal de Educação, Ciência e Tecnologia de Minas Gerais (BR)
Corresponding author
Antunes, Hélio Marcos André
Venue
International Journal of Electrical Power & Energy Systems
Publisher
Elsevier BV
Published
2020-10
Volume
121
Pages
106072
ISSN
0142-0615 (ISSN-L)
OpenAlex
W3020255803
Cited by
27
References
30
Citations by year
2026: 2 · 2025: 3 · 2024: 3 · 2023: 4 · 2022: 8 · 2021: 5 · 2020: 2
FWCI
2.28
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
International Journal of Electrical Power & Energy Systems (publishedVersion)
Funders
  • Graduate Program in Electrical Engineering of the Federal University of Minas Gerais
  • Federal University of Espirito Santo
  • CAPES
  • CNPQ
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
Keywords
grid-forming inverters, fault tolerance, AC microgrids, islanded operation, bidirectional converter, voltage source inverter, H-bridge topology, delta connection, zigzag transformer, centralized control, distributed generation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.