Cell‐free placental mRNA in maternal plasma to predict placental invasion in patients with placenta accreta
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective: To evaluate whether measuring cell‐free placental mRNA in maternal plasma improves the diagnostic accuracy of ultrasound and color Doppler in detecting placental invasion in patients at risk for placenta accreta. Methods: Thirty‐five singleton pregnant women of more than 28 weeks of gestation and at risk for placenta accreta underwent ultrasound and color Doppler assessment. Cell‐free placental mRNA in maternal plasma was measured using real‐time reverse‐transcription polymerase chain reaction. Patients were classified into 2 groups based on the findings at cesarean delivery and histological examination: women with placenta accreta (n = 7) and women without placenta accreta (n = 28). Results: The median MoM (multiples of the median) value of cell‐free placental mRNA was significantly higher in patients with placenta accreta than in those without placenta accreta (6.50 vs 2.60; P < 0.001. Moreover, cell‐free placental mRNA was significantly elevated in patients with placenta increta and percreta than in those with simple accreta. Six false‐positive results were found on ultrasound, all from patients without placenta accreta and an insignificant rise in cell‐free placental mRNA levels. Conclusion: Measuring cell‐free placental mRNA in maternal plasma may increase the accuracy of ultrasound and color Doppler in prenatal prediction of placental invasion in patients with suspected placenta accreta.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maternal Morbidity Associated With Multiple Repeat Cesarean Deliveries
Silver, R. M., Landon, M. B., Rouse, D. J., Leveno, K. J., Spong, C. Y., Thom, E. A., Moawad, A. H., Caritis, S. N., Harper, M., Wapner, R. J., et al. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000219750.79480.84 · Cited by 1,909
Abnormal placentation: Twenty-year analysis
Wu, S., Kocherginsky, M., & Hibbard, J. U. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.074 · Cited by 1,331
Cited by
Obstetric Care Consensus No. 7: Placenta Accreta Spectrum
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002983 · Cited by 523
Cahill, A. G., Beigi, R., Heine, R. P., Silver, R. M., & Wax, J. R. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.042 · Cited by 481
D'Antonio, F., Iacovella, C., & Bhide, A. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13194 · Cited by 398
Proposal for standardized ultrasound descriptors of abnormally invasive placenta ( AIP )
Collins, S. L., Ashcroft, A., Braun, T., Calda, P., Langhoff‐Roos, J., Morel, O., Stefanovic, V., Tutschek, B., Chantraine, F., & on behalf of the European Working Group on Abnormally Invasive Placenta (EW‐AIP) (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14952 · Cited by 331
Placenta Accreta Spectrum: A Review of Pathology, Molecular Biology, and Biomarkers
Bartels, H. C., Postle, J. D., Downey, P., & Brennan, D. J. (2018) · Disease Markers · doi:10.1155/2018/1507674 · Cited by 233
Metadata
- Authors
- El Behery, M. M., Rasha L., E., & El Alfy, Y.
- Venue
- International Journal of Gynecology & Obstetrics
- Publisher
- Wiley
- Published
- 2010-01-13
- Volume
- 109
- Issue
- 1
- Pages
- 30-33
- ISSN
- 0020-6695 (ISSN-L)
- 0020-7292
- 1879-3479
- OpenAlex
- W2000352365
- Cited by
- 47
- References
- 2
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.