Finite circular fin method for heat and mass transfer characteristics for plain fin-and-tube heat exchangers under fully and partially wet surface conditions
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For N=1 and N=2, influence of fin pitch variation on heat transfer performance is negligible under dry conditions, differing from Wang et al. [90] report of dependence.
“The authors found that, for N=1 and N = 2, the influence of fin pitch variation on heat transfer performance was negligible under dry conditions, which differs from the report by Wang et al. [90] of dependence.”
Cites
Xia, Y., & Jacobi, A. M. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.08.008 · Cited by 62 · cited 1× · see citing works
“Recently, Xia and Jacobi [ 13 ] formulated the logarithmicmean temperature difference (LMTD) and logarithmicmean enthalpy difference (LMED) methods for fully dry, fully wet, partially wet and frosted surface conditions.”
Flagged first, then by citations
Cited by
Sorted by citations
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Ma, X., Ding, G., Zhang, Y., & Wang, K. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.03.001 · Cited by 82 · see citing works
- Authors
- Pirompugd, W., Wang, C.-C., & Wongwises, S.
- Affiliations
- Burapha University (TH)
- Industrial Technology Research Institute (TW)
- King Mongkut's University of Technology Thonburi (TH)
- Corresponding author
- Wongwises, Somchai
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2007-02
- Volume
- 50
- Issue
- 3-4
- Pages
- 552-565
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W2054639454
- Cited by
- 60
- References
- 1
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 3 · 2019: 4 · 2018: 3 · 2016: 8 · 2015: 6 · 2014: 4 · 2013: 2
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Funders
- Thailand Research Fund
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Keywords
- finned tube heat exchanger, plain fins, dehumidification, sensible heat transfer, mass transfer, fin spacing, relative humidity, tube rows, performance correlation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review