The DOI matches its Crossref record.
Heat transfer enhancement in a parallel, finless heat exchanger using a longitudinal vortex generator, Part A: Numerical investigation
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In finless heat exchangers, condensate can drop rapidly under the influence of gravity because there are no fins in the way.
“For finless heat exchangers, the condensate can drop rapidly under the influence of gravity because there are no fins in the way, as shown in Fig. 19 (b).”
The thermal performance of finless heat exchangers is lower than that of louver fin heat exchangers under dry conditions.
“However, the thermal performance of finless heat exchangers is lower than that of louver fin heat exchangers under dry conditions.”
Under wet conditions, the finless heat exchanger with LVG performs similarly to the louver fin heat exchanger in terms of thermal-hydraulic performance due to its excellent drainage performance.
“Under wet conditions, the finless heat exchanger with LVG performed similarly to the louver fin heat exchanger in terms of thermal-hydraulic performance due to its excellent drainage performance.”
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 24
- N. Shikazono, D. Okawa, M. Kobayashi, N. Kasagi, T. Waki, I. Kandori, S. Hataya, Research and development of high-performance compact finless heat exchanger, in: Proceedings of 6th International Conference on Enhanced, Compact and Ultra-Compact Heat Exchangers: Science, Engineering and Technology, CHE2007-0017.
- H. Nakano, H. Onishi, Y. Tada, A. Takimoto, Heat transfer characteristics of finless tube heat exchanger under frost conditions with mist deposition, in: Proceedings of Thermal Engineering Conference, 2007. pp. 253–254. · DOI
- H. Onishi, S. Mido, Y. Tada, A. Takimoto, Heat transfer characteristics with frosting of flat tube heat exchanger for refrigerator-performance comparison with fin-and-tube heat exchanger, in: The 46th Japanese National Heat Transfer Symposium, C1-311, 2009.
- A. Kaneko, M. Katsuta, R. Hori, Research of heat transfer and pressure drop characteristic of concavo-convex plate, in: The 48th Japanese National Heat Transfer Symposium, G321, 2011.
- Onishi, H., Yonekura, H., Tada, Y., and Takimoto, A. “Heat transfer performance of finless flat tube heat exchanger with vortex generator,” 14th International Heat Transfer Conference, IHTC14-23232, pp. 799-807, (2010). · DOI
- Y.L. He, Y. Zhang, Advances and outlooks of heat transfer enhancement by longitudinal vortex generators. arXiv preprint arXiv:1602.00323, 2016. · arXiv
- Wu, 2007, Investigation on laminar convection heat transfer in fin-and-tube heat exchanger in aligned arrangement with longitudinal vortex generator from the viewpoint of field synergy principle, Appl. Therm. Eng., 27, 2609, 10.1016/j.applthermaleng.2007.01.025 · DOI
- Wu, 2008, Numerical study on laminar convection heat transfer in a rectangular channel with longitudinal vortex generator. Part A: Verification of field synergy principle, Int. J. Heat Mass Transf., 51, 1179, 10.1016/j.ijheatmasstransfer.2007.03.032 · DOI
- Chen, 1998, Conjugate heat transfer of a finned oval tube with a punched longitudinal vortex generator in form of a delta winglet—parametric investigations of the winglet, Int. J. Heat Mass Transf., 41, 3961, 10.1016/S0017-9310(98)00076-3 · DOI
- Chen, 1998, Heat transfer enhancement of a finned oval tube with punched longitudinal vortex generators in-line, Int. J. Heat Mass Transf., 41, 4151, 10.1016/S0017-9310(98)00130-6 · DOI
- Chen, 2000, Heat transfer enhancement of finned oval tubes with staggered punched longitudinal vortex generators, Int. J. Heat Mass Transf., 43, 417, 10.1016/S0017-9310(99)00157-X · DOI
- Fiebig, 1993, Wing-type vortex generators for fin-and-tube heat exchangers, Exp. Therm. Fluid Sci., 7, 287, 10.1016/0894-1777(93)90052-K · DOI
- Biswas, 1994, Heat transfer enhancement in fin-tube heat exchangers by winglet type vortex generators, Int. J. Heat Mass Transf., 37, 283, 10.1016/0017-9310(94)90099-X · DOI
- Wang, 2002, Flow visualization of annular and delta winglet vortex generators in fin-and-tube heat exchanger application, Int. J. Heat Mass Transf., 45, 3803, 10.1016/S0017-9310(02)00085-6 · DOI
- Torii, 2002, Heat transfer enhancement accompanying pressure-loss reduction with winglet-type vortex generators for fin-tube heat exchangers, Int. J. Heat Mass Transf., 45, 3795, 10.1016/S0017-9310(02)00080-7 · DOI
- Pesteei, 2005, Experimental study of the effect of winglet location on heat transfer enhancement and pressure drop in fin-tube heat exchangers, Appl. Therm. Eng., 25, 1684, 10.1016/j.applthermaleng.2004.10.013 · DOI
- Wang, 2007, Experimental study of heat transfer enhancement in narrow rectangular channel with longitudinal vortex generators, Nucl. Eng. Des., 237, 686, 10.1016/j.nucengdes.2006.09.003 · DOI
- Leu, 2004, Heat transfer and fluid flow analysis in plate-fin and tube heat exchangers with a pair of block shape vortex generators, Int. J. Heat Mass Transf., 47, 4327, 10.1016/j.ijheatmasstransfer.2004.04.031 · DOI
- Chu, 2009, Three-dimensional numerical study on fin-and-oval-tube heat exchanger with longitudinal vortex generators, Appl. Therm. Eng., 29, 859, 10.1016/j.applthermaleng.2008.04.021 · DOI
- He, 2013, Analysis of heat transfer and pressure drop for fin-and-tube heat exchangers with rectangular winglet-type vortex generators, Appl. Therm. Eng., 61, 770, 10.1016/j.applthermaleng.2012.02.040 · DOI
- Kim, 2004, Heat-transfer and friction characteristics for the louvered-fin heat exchanger, J. Thermophys. Heat Transf., 18, 58, 10.2514/1.9123 · DOI
- Bhowmik, 2009, Analysis of heat transfer and pressure drop characteristics in an offset strip fin heat exchanger, Int. Commun. Heat Mass Transf., 36, 259, 10.1016/j.icheatmasstransfer.2008.11.001 · DOI
- Hwang, 2016, Performance comparison of modified offset strip fins using a CFD analysis, Int. J. Air-Condition. Refrig., 24, 1650015, 10.1142/S2010132516500152 · DOI
- Hwang, 2012, CFD analysis of fin tube heat exchanger with a pair of delta winglet vortex generators, J. Mech. Sci. Technol., 26, 2949, 10.1007/s12206-012-0702-2 · DOI
Cited by
Sorted by citations
Zhang, L., Song, M., Mao, N., & Dong, J. (2022) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.122192 · Cited by 38
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26
Metadata
- Authors
- Li, J., Dang, C., & Hihara, E.
- Affiliations
- The University of Tokyo (JP)
- Corresponding author
- Li, Jiyang
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 128
- Pages
- 87-97
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W2891333396
- Cited by
- 30
- References
- 0
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 5 · 2022: 4 · 2021: 7 · 2020: 3 · 2019: 3
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Funders
- New Energy and Industrial Technology Development Organization
- China Scholarship Council
- Ministry of Education, Culture, Sports, Science and Technology
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Ranque-Hilsch vortex tube
- Keywords
- heat transfer enhancement, longitudinal vortex generators, air conditioners, vortex generator geometry, condensation, air flow
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review