Investigation on thermal performance of water-cooled Li-ion pouch cell and pack at high discharge rate with U-turn type microchannel cold plate

Patil, Mahesh Suresh, Seo, Jae-Hyeong, Panchal, Satyam, Jee, Sang-Won, Lee, Moo-Yeon · 2020 · International Journal of Heat and Mass Transfer

Abstract

The objective of this study involves investigation and simulation on thermal performance of water-cooled lithium-ion battery cell and pack used in electric vehicles at high discharge rate with a U-turn type microchannel cold plate and recommending an optimal cooling strategy by considering the effects of various parameters including different discharge rates, inlet coolant mass flow rates, inlet coolant temperatures, surface area coverage ratios via changing the number of cooling channels, channel hydraulic diameters via changing maximum width of cooling channels, and flow pattern layouts. Experiments were conducted and the simplified heat generation rate calculation method was proposed to use as input heat source in the numerical study. The cold plate with surface area coverage ratio = 0.750 and channel hydraulic diameter = 1.54 mm was suggested to enhance battery cooling. The suggested flow pattern layout corresponding to cross flow with alternate single inlet and single outlet channel decreases the maximum temperature and temperature difference by 32.2% and 950.1%, respectively, when compared to the original flow pattern layout corresponding to parallel flow with 10 inlet channels at one side. The study demonstrated that optimized cooling parameters could maintain the maximum temperature and temperature non-uniformity of 50 V battery pack below 40 °C and 4 °C, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijheatmasstransfer.2020.119728

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 233

Metadata

Authors
Patil, M. S., Seo, J.-H., Panchal, S., Jee, S.-W., & Lee, M.-Y.
Venue
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Published
2020-07
Volume
155
Pages
119728
ISSN
0017-9310 (ISSN-L)
OpenAlex
W3024507854
Cited by
233
References
4
FWCI
12.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigation on thermal performance of water-cooled Li-ion pouch cell and pack at high discharge rate with U-turn type microchannel cold plate. https://app.cochat.ai/papers/10.1016/j.ijheatmasstransfer.2020.119728
The paper
Patil, M. S., Seo, J.-H., Panchal, S., Jee, S.-W., & Lee, M.-Y. (2020). Investigation on thermal performance of water-cooled Li-ion pouch cell and pack at high discharge rate with U-turn type microchannel cold plate. International Journal of Heat and Mass Transfer. https://doi.org/10.1016/j.ijheatmasstransfer.2020.119728

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.