The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Influence of the operation mode on PEM water electrolysis degradation
Abstract
This paper compares the performance over time of seven different operation modes with the scope of investigating realistic degradation responses of a polymer electrolyte membrane water electrolysis (PEM WE) to different operation modes for grid-balancing services. Among these modes are constant current and constant voltage operations at different temperatures and current cycling operations, including a solar profile. It was found that faster current cycling improved the overall cell performance over the test period of 500 h, mainly due to a decrease in total ohmic resistance, which is also observed during the break-in phase preceding the experiments. Dynamic operation led to more severe fluoride emission from the catalyst binder, which improved the performance in terms of cell potential but could be a concern for long term degradation as membrane thinning promotes higher gas crossover. All other operation modes on the other hand suffered from an increase in total ohmic resistance, leading to an overall performance decrease, which is suspected to be due to the passivation of the Ti components. Higher operating temperatures were found to enhance cell performance, but are detrimental from a durability point of view since they exacerbate both membrane thinning and passivation processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the Effects of Compression and Constraints on Water Uptake of Fuel-Cell Membranes
Kusoglu, A., Kienitz, B. L., & Weber, A. Z. (2011) · Journal of The Electrochemical Society · doi:10.1149/2.097112jes · Cited by 72
Cited by
Anion-Exchange Membrane Water Electrolyzers
Du, N., Roy, C., Peach, R., Turnbull, M., Thiele, S., & Bock, C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00854 · Cited by 1,075
Perspective of the role of hydrogen in the 21st century energy transition
Capurso, T., Stefanizzi, M., Torresi, M., & Camporeale, S. M. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2021.114898 · Cited by 871
Water Electrolysis toward Elevated Temperature: Advances, Challenges and Frontiers
Zhang, W., Liu, M., Gu, X., Shi, Y., Deng, Z., & Cai, N. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00573 · Cited by 441
Wang, C. R., Stansberry, J. M., Mukundan, R., Chang, H.-M. J., Kulkarni, D., Park, A. M., Plymill, A. B., Firas, N. M., Liu, C. P., Lang, J. T., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00904 · Cited by 402
A comprehensive review of alkaline water electrolysis mathematical modeling
Hu, S., Guo, B., Ding, S., Yang, F., Dang, J., Liu, B., Gu, J., Ma, J., & Ouyang, M. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.120099 · Cited by 253
Metadata
- Authors
- Frensch, S. H., Fouda-Onana, F., Serre, G., Thoby, D., Araya, S. S., & Kær, S. K.
- Venue
- International Journal of Hydrogen Energy
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 44
- Issue
- 57
- Pages
- 29889-29898
- ISSN
- 0360-3199 (ISSN-L)
- OpenAlex
- W2980831519
- Cited by
- 223
- References
- 1
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of the operation mode on PEM water electrolysis degradation. https://app.cochat.ai/papers/10.1016/j.ijhydene.2019.09.169
- The paper
- Frensch, S. H., Fouda-Onana, F., Serre, G., Thoby, D., Araya, S. S., & Kær, S. K. (2019). Influence of the operation mode on PEM water electrolysis degradation. International Journal of Hydrogen Energy. https://doi.org/10.1016/j.ijhydene.2019.09.169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.