The catheter to vein ratio and rates of symptomatic venous thromboembolism in patients with a peripherally inserted central catheter (PICC): A prospective cohort study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND Peripherally inserted central catheters (PICCs) are a common vascular access device used in clinical practice. Their use may be complicated by adverse events such as venous thromboembolism (VTE). The size of the vein used for PICC insertion and thus the catheter to vein ratio is thought to be a controllable factor in the reduction of VTE rates in patients who have a PICC. However, an optimal catheter to vein ratio for PICC insertion has not previously been investigated to inform clinical practice. OBJECTIVES To determine the effect of the catheter to vein ratio (proportion of the vein measured at the insertion point taken up by the catheter) on rates of symptomatic VTE in patients with a PICC and identify the optimal ratio cut-off point to reduce rates of this adverse event. METHOD Adult patients waiting for PICC insertion at a large metropolitan teaching hospital were recruited between May and December 2013. Vein diameter at the PICC insertion site was measured using ultrasound with in-built callipers. Participants were followed up at eight weeks to determine if they developed symptomatic VTE. RESULTS Data were available for 136 patients (50% cancer; 44% infection; 6% other indication for PICC). Mean age was 57 years with 54% males. There were four cases of confirmed symptomatic VTE (two involving the deep veins, one peripheral vein and one pulmonary embolism). Receiver operator characteristic (ROC) analysis determined that a 45% catheter to vein ratio was the ideal cut off point to maximise sensitivity and specificity (AUC 0.761; 95% CI 0.681-0.830). When a ratio of 46% or above was compared to one that was less than or equal to 45% using a log binomial generalised linear model it was found that participants with a catheter to vein ratio >45% were 13 times more likely to suffer VTE (relative risk 13, p=0.022; CI 1.445-122.788). CONCLUSION It was found that a 45% catheter to vein ratio was the optimal cut off with high sensitivity and specificity to reduce the risk of VTE. However, further research is needed to confirm these results as although adequately powered; the number of cases of VTE was comparatively small, resulting in wide confidence intervals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infusion Nursing Standards of Practice
Gorski, L. A. (2007) · Journal of Infusion Nursing · doi:10.1097/01.nan.0000270673.13439.95 · Cited by 602
Superficial Venous Thrombosis and Venous Thromboembolism: A Large, Prospective Epidemiologic Study
Decousus, H., Quéré, I., Presles, E., Becker, F., Barrellier, M.-T., Chanut, M., Gillet, J.-L., Guenneguez, H., Leandri, C., Mismetti, P., et al. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-4-201002160-00006 · Cited by 353
Infusion Nursing Standards of Practice
Gorski, L. A. (2007) · Journal of Infusion Nursing · doi:10.1097/00129804-200701000-00004 · Cited by 264
Venous Thrombosis Related to Peripherally Inserted Central Catheters
Grove, J. R., & Pevec, W. C. (2000) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61797-7 · Cited by 237 · cited 4×
“Several prospective and retrospective studies set in acute care facilities have determined higher rates of VTE with patients who have a larger diameter PICC (Grove and Pevec, 2000; Chopra et al., 2014).”
BackgroundMethodInfluentialChopra, V., Ratz, D., Kuhn, L., Lopus, T., Lee, A., & Krein, S. (2014) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12549 · Cited by 166 · cited 9×
“This was an overall symptomatic VTE rate of 2.9% (0.83 VTE per 1000 PICC days), which is similar to previous research in comparable populations (Liem et al., 2012; Leroyer et al., 2013; Chopra et al., 2014).”
BackgroundMethodResultInfluentialOld and new risk factors for upper extremity deep venous thrombosis
Blom, J. W., Doggen, C. J. M., Osanto, S., & Rosendaal, F. R. (2005) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01625.x · Cited by 158 · cited 1×
“One study in the Netherlands found nearly an eight-fold increase in risk of upper arm thrombosis for cancer patients without a central venous access device in place (Blom et al., 2005).”
BackgroundPériard, D., Monney, P. A., Waeber, G., Zurkinden, C., Mazzolai, L., Hayoz, D., Doenz, F., Zanetti, G. M. R., Wasserfallen, J., & Denys, A. L. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.03053.x · Cited by 151 · cited 1×
“There is a paucity of studies analysing PICC associated SVT, but increasingly researchers are including this complication in VTE outcome measures (Periard et al., 2008; Itkin et al., 2014).”
BackgroundChanging concepts in long-term central venous access: Catheter selection and cost savings
Horattas, M. C., Trupiano, J. K., Hopkins, S., Pasini, D., MARTINO, C. R., & Murty, A. S. (2001) · American Journal of Infection Control · doi:10.1067/mic.2001.111536 · Cited by 117 · cited 1×
“PICC use has increased worldwide due to costeffective nurse insertion teams, increased patient satisfaction and to facilitate out of hospital care (Horattas et al., 2001; Sharp et al., 2014).”
BackgroundItkin, M. G., Mondschein, J. I., Stavropoulos, S. W., Shlansky-Goldberg, R. D., Soulen, M. C., & Trerotola, S. O. (2013) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2013.10.009 · Cited by 88 · cited 3×
“Previous research, which has set a minimum vein size for PICC insertion, has found decreased thrombus rates associated with lower catheter to vein ratios, but the definitive maximum ratio that can be used is not apparent (Meyer, 2011; Itkin et al., 2014).”
BackgroundHow I treat superficial venous thrombosis
Kitchens, C. S. (2010) · Blood · doi:10.1182/blood-2010-05-286690 · Cited by 68 · cited 1×
“SVT is uncomfortable for the patient, may result in removal of the device and can extend into deeper vasculature with resulting thromboembolic complications (Decousus et al., 2010; Kitchens, 2011).”
BackgroundProspective follow-up of complications related to peripherally inserted central catheters
Leroyer, C., Lashéras, A., Marie, V. H. J., Bras, Y. L., Carteret, T., Dupon, M., & Rogues, A. M. (2013) · Médecine et Maladies Infectieuses · doi:10.1016/j.medmal.2013.06.013 · Cited by 68 · cited 2×
“This was an overall symptomatic VTE rate of 2.9% (0.83 VTE per 1000 PICC days), which is similar to previous research in comparable populations (Liem et al., 2012; Leroyer et al., 2013; Chopra et al., 2014).”
ResultInfluentialRoach, R. E. J., Lijfering, W. M., van Hylckama Vlieg, A., Helmerhorst, F. M., Rosendaal, F. R., & Cannegieter, S. C. (2013) · Blood · doi:10.1182/blood-2013-07-518159 · Cited by 64 · cited 1×
“In the lower extremities, there is increasing evidence that rather than a benign issue, symptomatic SVT is closely associated with VTE and may be a marker of risk (Decousus et al., 2010; Roach et al., 2013).”
BackgroundSharp, R., Grech, C., Fielder, A. L., Mikocka‐Walus, A. A., Cummings, M., & Esterman, A. (2014) · Contemporary Nurse · doi:10.1080/10376178.2014.11081923 · Cited by 64 · cited 1×
“PICC use has increased worldwide due to costeffective nurse insertion teams, increased patient satisfaction and to facilitate out of hospital care (Horattas et al., 2001; Sharp et al., 2014).”
BackgroundSelf-citationCentral Venous Catheter-Related Thrombosis: A Systematic Review
Yacopetti, N. (2008) · Journal of Infusion Nursing · doi:10.1097/01.nan.0000326833.59655.9e · Cited by 39 · cited 1×
“Stasis is a key element in the formation of thrombus according to Virchow’s triad (Yacopetti, 2008).”
Managing Peripherally Inserted Central Catheter Thrombosis Risk: A Guide for Clinical Best Practice
Meyer, B. M. (2011) · Journal of the Association for Vascular Access · doi:10.2309/java.16-3-3 · Cited by 26 · cited 3×
“Previous research, which has set a minimum vein size for PICC insertion, has found decreased thrombus rates associated with lower catheter to vein ratios, but the definitive maximum ratio that can be used is not apparent (Meyer, 2011; Itkin et al., 2014).”
BackgroundMethodInfluentialSharp, R., Grech, C., Fielder, A. L., et al. (2014) · Contemporary Nurse · doi:10.5172/conu.2014.5066 · Cited by 9
Self-citation
Cited by
Spencer, T. R., & Pittiruti, M. (2019) · The Journal of Vascular Access · doi:10.1177/1129729818804718 · Cited by 203
“, 45, 50– Utilizing the caliber measurement tool capabilities of an US machine allows clinicians to provide greater assessment for the correct size of the vessels prior to procedures.”
Association of Anaesthetists guidelines: safe vascular access 2025
Johnston, A. J., Simpson, M. J., McCormack, V., Barton, A., Bennett, J., Chalisey, A., Crane, J., Curry, S., Laycock, H., Patel, D., et al. (2025) · Anaesthesia · doi:10.1111/anae.16727 · Cited by 32
“%) should be occupied by the catheter, leaving two-thirds unobstructed [32, 33].”
Metadata
- Authors
- Sharp, R., Cummings, M., Fielder, A., Mikocka-Walus, A., Grech, C., & Esterman, A.
- Venue
- International Journal of Nursing Studies
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 52
- Issue
- 3
- Pages
- 677-685
- ISSN
- 0020-7489 (ISSN-L)
- OpenAlex
- W2053165340
- Cited by
- 175
- References
- 16
- FWCI
- 9.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.