CoChat

Medical device-related pressure ulcers: A systematic review and meta-analysis

Open access
Jackson, Debra, Sarki, Ahmed M, Betteridge, Ria, Brooke, Joanne · 2019 · International Journal of Nursing Studies
Cited by 230

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To review observational studies reporting medical device-related pressure injuries and to identify the medical devices commonly associated with pressure injuries. DESIGN: A systematic review of primary research was undertaken, according to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. DATA SOURCES: December 2018. Studies that reported the prevalence or incidence of medical device-related pressure injuries and published in English language were included in the review. REVIEW METHODS: The eligibility of studies was evaluated independently by three of the four authors and audited by an independent researcher. The titles and abstracts of all studies were screened to identify studies that met the inclusion criteria. Full-text articles of the remaining studies were obtained and screened against the inclusion criteria. Risk of bias was assessed using the Newcastle-Ottawa scale. Meta-analysis was conducted using the 'metaprop' routine, with estimates of medical device-related pressure injuries from the included studies pooled using DerSimonian-Laird random-effects model. Meta-regression analysis was also conducted to examine between-study heterogeneity. RESULTS: Twenty-nine studies (17 cross-sectional studies; 12 cohort studies) comprising data on 126,150 patients were eligible for inclusion in this review. The mean ages for patients were approximately 36.2 years (adults) and 5.9 years (children). The estimated pooled incidence and prevalence of medical device-related pressure injuries were 12% (95% CI 8-18) and 10% (95% CI 6-16) respectively. These results should be interpreted with caution given the high levels of heterogeneity observed between included studies. The commonly identified medical devices associated with the risk of developing medical device-related pressure injuries include respiratory devices, cervical collars, tubing devices, splints, and intravenous catheters. CONCLUSIONS: Medical device-related pressure injuries are among key indicators of patient safety and nursing quality in healthcare facilities. This systematic review and meta-analysis provide up-to-date estimates of the extent and nature of medical device-related pressure injuries, and the findings suggest that device-related pressure injuries are a public health issue of significance, especially as these injuries affect patients' wellbeing and increase the cost of care for both patients and providers. Further research is required to inform strategies for increasing the reporting and risk assessment of medical device-related pressure injuries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijnurstu.2019.02.006

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Jackson, D., Sarki, A. M., Betteridge, R., & Brooke, J.
Venue
International Journal of Nursing Studies
Publisher
Elsevier BV
Published
2019-04
Volume
92
Pages
109-120
ISSN
0020-7489 (ISSN-L)
OpenAlex
W2911712979
Cited by
230
References
4
FWCI
7.91
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.