The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In 2020, roughly 2 billion AC units were in operation in the world, with residential ACs representing 68% of these units [196].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [196]
In the citing paper
“Average cooling demand around the world is responsible for 15% of peak electricity demand; but during hot days, cooling can be responsible for up to 50% and more of residential peak electricity demand [196].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [196]
In the citing paper
“The market of AC units is growing in an accelerated way, with estimated sales increasing by 10% between 2018 and 2019 (mainly in emerging and developing countries) [196].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [196]
In the citing paper
“The study also found that this problem could be mitigated by using an evaporative-cooled condenser, which maintained the cooling capacity of the airconditioner at 6.7 kW when the outdoor air temperature was 49 °C.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [195]
In the citing paper
“Average efficiency rating of installed AC units has increased by 15% between 2010 and 2020 [196], but still far behind the most efficient products on the market [196].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [196]
Citations
Cites
Application of evaporative cooling on the condenser of window-air-conditioner
Hajidavalloo, E. (2007) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2006.12.014 · Cited by 135
Self-citationNumerical model of sprayed air cooled condenser coupled to refrigerating system
Youbi-Idrissi, M., Macchi-Tejeda, H., Fournaison, L., et al. (2007) · Energy Conversion and Management · doi:10.1016/j.enconman.2007.01.025 · Cited by 61
Goswami, D. Y., Mathur, G. D., & Kulkarni, S. (1993) · Journal of Solar Energy Engineering · doi:10.1115/1.2930051 · Cited by 56
Application of Direct Evaporative Coolers for Improving the Energy Efficiency of Air-Cooled Chillers
Yu, F. W., & Chan, K. T. (2005) · Journal of Solar Energy Engineering · doi:10.1115/1.1866144 · Cited by 35
Enhanced performance of air-cooled chillers using evaporative cooling
Zhang, H., You, S., Hongxing, Y., et al. (2000) · Building Services Engineering Research and Technology · doi:10.1177/014362440002100401 · Cited by 30
Cited by
A review of different strategies for HVAC energy saving
Vakiloroaya, V., Samali, B., Fakhar, A., & Pishghadam, K. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.10.023 · Cited by 521
Overview of the Maisotsenko cycle – A way towards dew point evaporative cooling
Mahmood, M. H., Sultan, M. A., Miyazaki, T., Koyama, S., & Maisotsenko, V. S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.08.022 · Cited by 264
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Harby, K., Gebaly, D. R., Koura, N. S. A., & Hassan, M. S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.313 · Cited by 154
Experimental investigation of air conditioning system using evaporative cooling condenser
Wang, T., Sheng, C., & Nnanna, A. G. A. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.047 · Cited by 123
Martínez, P., Martínez, P., Ramírez, J. R., et al. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.01.067 · Cited by 110
Nada, S. A., Fouda, A., Mahmoud, M. A., et al. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.109449 · Cited by 94
Mujeebu, M. A., & Alshamrani, O. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.327 · Cited by 112
Air cooling by evaporating droplets in the upward flow of a condenser
Tissot, J., Boulet, P., Trinquet, F., et al. (2011) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2011.06.004 · Cited by 92
Martínez, P., Ramírez, J. R., Martinez, P. J., Kaiser, A. S., & Miralles, M. L. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.04.065 · Cited by 88
Cooling and Energy-Saving Performance of Different Green Wall Design: A Simulation Study of a Block
Li, J., Zheng, B., Shen, W., Xiang, Y., Chen, X., & Qi, Z. (2019) · Energies · doi:10.3390/en12152912 · Cited by 89
Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems
Islam, M. R., Jahangeer, K. A., & Chua, K. J. (2015) · Energy · doi:10.1016/j.energy.2015.05.005 · Cited by 71
He, S., Gurgenci, H., Guan, Z., et al. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.12.037 · Cited by 70
“[42–48].”
Hybrid cooling systems: A review and an optimized selection scheme
Kojok, F., Fardoun, F., Younès, R., & Outbib, R. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.092 · Cited by 69
Yang, J., Chan, K. T., Wu, X., et al. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.02.001 · Cited by 68
Experimental research on spray evaporative cooling system applied to air-cooled chiller condenser
Yang, H., Rong, L., Liu, X., et al. (2020) · Energy Reports · doi:10.1016/j.egyr.2020.04.001 · Cited by 65
She, X., Yin, Y., & Zhang, X. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.10.057 · Cited by 63
Ibrahim, N. I., Al‐Farayedhi, A. A., & Gandhidasan, P. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.09.042 · Cited by 62
Harby, K., & Al‐Amri, F. G. (2019) · Energy · doi:10.1016/j.energy.2019.06.031 · Cited by 61
Optimizing the pad thickness of evaporative air-cooled chiller for maximum energy saving
Hao, X., Zhu, C., Lin, Y., et al. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.02.028 · Cited by 58
Zhang, L., Zha, X., Song, X., et al. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.10.100 · Cited by 55
Sarntichartsak, P., & Thepa, S. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.08.063 · Cited by 53
Atmaca, İ., Şenol, A., & Çağlar, A. (2021) · Engineering Science and Technology an International Journal · doi:10.1016/j.jestch.2021.09.010 · Cited by 51
Liu, H., Zhou, Q., Liu, Y., et al. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.03.012 · Cited by 49
Improved energy performance of a refrigerating machine using water spray upstream of the condenser
Tissot, J., Boulet, P., Trinquet, F., et al. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.08.025 · Cited by 49
Su, W., Li, W., Zhou, J., & Zhang, X. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.09.085 · Cited by 47
Li, W., Shi, W., Wang, J., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110808 · Cited by 46
Experimental study on air cooling by spray in the upstream flow of a heat exchanger
Tissot, J., Boulet, P., Labergue, A., et al. (2012) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2012.06.005 · Cited by 43
Dhamneya, A. K., Rajput, S. P. S., & Singh, A. (2018) · Journal of Building Engineering · doi:10.1016/j.jobe.2018.01.012 · Cited by 43
Yang, H., Pei, N., Liu, L., et al. (2021) · Energy Reports · doi:10.1016/j.egyr.2021.01.037 · Cited by 42
An analysis on the energy efficiency of air-cooled chillers with water mist system
Yang, J., Chan, K. T., Wu, X., et al. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.09.018 · Cited by 40
Numerical study on performance improvement of air-cooled condenser by water spray cooling
Xiao, L., Ge, Z., Yang, L., et al. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.05.006 · Cited by 40
Elnagar, E., Zeoli, A., Rahif, R., Attia, S., & Lemort, V. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113179 · Cited by 45
“Hajidavallo and Eghtedari [36] experimentally showed that an evaporative cooler coupled with an air-cooled condenser can reduce the power consumption of the air-conditioner by up to 20% and increase the system EER by 50%.”
BackgroundMethodInfluentialThe design of countercurrent evaporative condensers with the hybrid method
Fiorentino, M., & Starace, G. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.11.076 · Cited by 38
Zhu, X., Chen, S., Shen, S., et al. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114825 · Cited by 37
Performance improvement of a split air conditioner by using an energy saving device
Chen, W.-H., Mo, H.-E., & Teng, T.-P. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.06.055 · Cited by 36
Review of Residential Air Conditioning Systems Operating under High Ambient Temperatures
Alawadhi, M., & Phelan, P. E. (2022) · Energies · doi:10.3390/en15082880 · Cited by 36
Ndukaife, T. A., & Nnanna, A. G. A. (2018) · Heat Transfer Engineering · doi:10.1080/01457632.2018.1436418 · Cited by 35
“Hajidavalloo and Eghtedari [14] retrofitted the condenser of a 1.”
BackgroundInfluentialEnhancement of heat exchanges on a condenser using an air flow containing water droplets
Boulet, P., Tissot, J., Trinquet, F., et al. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.08.039 · Cited by 35
Experimental study on heat transfer enhancement of wavy finned flat tubes by water spray cooling
Xiao, L., Wu, T., Feng, S., et al. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.03.054 · Cited by 33
Dhamneya, A. K., Rajput, S. P. S., & Singh, A. (2017) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2017.12.004 · Cited by 33
Pan, S., Pei, F., Wei, Y., et al. (2018) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.09.013 · Cited by 33
Nunes, J., da Silva, P. D., Andrade, L. P., & Gaspar, P. D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.019 · Cited by 34
Performance evaluation of energy efficient evaporatively air-cooled chiller
Kabeel, A. E., El-Samadony, Y. A. F., & Khiera, M. H. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.04.103 · Cited by 32
Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates
Jacob, T. A., Shah, N., & Park, W. Y. (2021) · Energy Conversion and Management · doi:10.1016/j.enconman.2021.114841 · Cited by 32
“Hajidavalloo and Eghtedari [17] retrofitted a 5.”
InfluentialPerformance assessment of an evaporative cooling-assisted window air conditioner
Sawant, A. P., Agrawal, N., & Nanda, P. (2011) · International Journal of Low-Carbon Technologies · doi:10.1093/ijlct/ctr029 · Cited by 29
“Hajidavalloo and Eghtedari [7] retrofitted the condenser of a 1.5 TR split air conditioning system by an evaporatively cooled condenser and showed the energy savings of the order of 11–20% as the outdoor temperature varied from 36 to 498C. Hwang et al. [8] developed an evaporative condenser for a split heat pump syste…”
BackgroundInfluentialSawan, R. I., Ghali, K., & Al‐Hindi, M. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2012.619395 · Cited by 28
“Hajidavalloo and Eghtedari ( 2010 ) have conducted experiments using evaporative cooling media pad with a 1.”
BackgroundMethodResultInfluentialEffect of Condenser Air Flow on the Performance of Split Air Conditioner
Elsayed, A. O., & Hariri, A. S. (2011) · Linköping electronic conference proceedings · doi:10.3384/ecp110572134 · Cited by 28
Ndukaife, T. A., & Nnanna, A. G. A. (2018) · Heat Transfer Engineering · doi:10.1080/01457632.2018.1429063 · Cited by 26
“Hajidavalloo and Eghtedari [15] retrofitted the condenser of a 1.5 TR split air conditioning system by an evaporatively cooled condenser and showed that energy savings of the order of 11–20% as the outdoor temperature varied from 36°C to 49°C, can be achieved.”
BackgroundInfluentialHussain, T. (2022) · Energy and Built Environment · doi:10.1016/j.enbenv.2022.01.003 · Cited by 25
Yu, F. W., Chan, K. T., Sit, R. K. Y., et al. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.04.027 · Cited by 25
Song, X., Yuan, H., Zhang, Y., Yu, B., Wang, D., Shi, J., & Chen, J. (2022) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2022.05.009 · Cited by 25
Deymi‐Dashtebayaz, M., Farahnak, M., Moraffa, M., et al. (2017) · Heat and Mass Transfer · doi:10.1007/s00231-017-2173-6 · Cited by 24
“Eghtedari [22] and their experimental tests at different ambient air temperatures showed remarkable improvement in performance of split type air-conditioners by reducing the condenser temperature, which leads to decrease the compressor work and higher cooling capacity.”
BackgroundLin, Y., Wang, W., Sun, Y., Liu, J., & Deng, S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.11.031 · Cited by 23
Lee, Y.-T., Wen, C., Chien, L., et al. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.122199 · Cited by 22
She, X., Yin, Y., Dong, Y., et al. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.11.044 · Cited by 21
Kim, B., Jo, S.-Y., & Jeong, J. (2022) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2022.102137 · Cited by 20
Ardita, I. N., & Subagia, I. W. A. (2018) · Journal of Physics Conference Series · doi:10.1088/1742-6596/953/1/012059 · Cited by 20
Energy conservation in room air conditioner unit by recovering cold energy from condensate
Nethaji, N., Tharves, M. S. I., & Nethaji, M. (2019) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2019.05.005 · Cited by 20
Experimental study on the evaporative cooling of an air-cooled condenser with humidifying air
Wen, M.-Y., Ho, C.-Y., Jang, K.-J., et al. (2013) · Heat and Mass Transfer · doi:10.1007/s00231-013-1243-7 · Cited by 19
“Hajidavallo and Eghtedari [10] investigated a refrigeration system using an evaporative cooled air condenser.”
MethodEffect of Ethylene glycol as Phase Change Material in a Cold Storage Unit on retention of cooling
Gupta, K. K., & Ramachandran, M. (2018) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/377/1/012190 · Cited by 18
Multi-perspective evaluation of integrated active cooling systems using fuzzy decision making model
Albahri, O. S., Alamoodi, A. H., Deveci, M., Albahri, A. S., Mahmoud, M. A., Sharaf, I. M., & Coffman, D. (2023) · Energy Policy · doi:10.1016/j.enpol.2023.113775 · Cited by 22
Jafarinejad, T., Shafii, M. B., & Roshandel, R. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100744 · Cited by 19
Yang, Y., Ren, C., Xie, D., Tu, M., Chen, G., & Luo, Q. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.122084 · Cited by 18
Solar facade for space cooling
Chan, H.-Y., Zhu, J. T., & Riffat, S. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.07.033 · Cited by 17
Balaji, N., Kumar, P. S. M., Velraj, R., et al. (2015) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-015-1644-7 · Cited by 17
“Hajidavalloo and Eghtedari [27] reported that their evaporatively cooled air condenser showed an 31.”
BackgroundInfluentialWei, J., Liu, J., Xu, X., et al. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114100 · Cited by 17
She, X., Yin, Y., & Zhang, X. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.12.006 · Cited by 16
Yin, Y., Zhu, D., Sun, J., et al. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.09.950 · Cited by 16
Performance Enhancement by Using Wet Pad in Vapor Compression Cooling System
Zaidan, M. H., Ibrahim, T. K., & Alkumait, A. A. R. (2019) · Journal of Engineering and Technological Sciences · doi:10.5614/j.eng.technol.sci.2019.51.1.4 · Cited by 16
“The performance and power consumption of an evaporative cooler used to cool the condenser of a vapor compression cycle cooler was investigated in [20].”
MethodLitardo, J., Pero, C. D., Molinaroli, L., Leonforte, F., & Aste, N. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109338 · Cited by 18
Theoretical and experimental analyses of mist precooling for an air-cooled chiller
Yu, F. W., Ho, W. T., Chan, K. T., et al. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.11.046 · Cited by 15
Kabeel, A. E., Abdelgaied, M., & Omara, Z. M. (2021) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-021-10810-6 · Cited by 15
Naveenprabhu, V., & Suresh, M. (2022) · Numerical Heat Transfer Part A Applications · doi:10.1080/10407782.2022.2101802 · Cited by 14
“Hajidavalloo and Eghtedari [11] built an evaporative cooler and combined it with air cooled condenser of a split airconditioner and evaluated system performance under various ambient air temperatures.”
BackgroundUsing Evaporative Cooling Methods for Improving Performance of an Air-cooled Condenser
Alhamdo, M. H., Theeb, M. A., & Abdulhameed, J. J. (2015) · Universal Journal of Mechanical Engineering · doi:10.13189/ujme.2015.030304 · Cited by 19
Gupta, S. K., Arora, B. B., & Arora, A. (2023) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2023.11.021 · Cited by 13
Performance Enhancement of Split Air Conditioner During Evaporative Cooling Application
Mainil, R. I., Sulaiman, A. W., Mainil, A. K., et al. (2021) · Journal of Advanced Research in Fluid Mechanics and Thermal Sciences · doi:10.37934/arfmts.86.2.147156 · Cited by 12
Kumar, S., Singh, J., Siyag, J., et al. (2020) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132520300062 · Cited by 12
Liu, L., Zhang, Q., Ling, L., & Ma, X. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2020.10.035 · Cited by 12
Zhang, Y., Ding, W., Zhang, Y., Shi, J., Zhang, G., & Zhou, D. (2025) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2025.116386 · Cited by 10
Naveenprabhu, V., & Suresh, M. (2023) · Industrial Crops and Products · doi:10.1016/j.indcrop.2023.116923 · Cited by 11
Abedalh, A. S., Hussein, A. T., & Yousif, A. A. (2023) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-023-12495-5 · Cited by 11
“Increased pressure could cause the refrigeration system's pressure control mechanism to switch off the compressor [5].”
BackgroundYang, Y., Zeng, J., Yang, B., Yin, L., & He, T. (2024) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2024.02.013 · Cited by 11
Aziz, A., Syahnan, M. R., Mainil, A. K., et al. (2021) · Journal of Advanced Research in Fluid Mechanics and Thermal Sciences · doi:10.37934/arfmts.86.1.140153 · Cited by 11
“On the other hands the reducing condenser temperature will reduce condenser pressure which results reduce compressor power consumption [10].”
BackgroundMethodExperimental optimization of the thermal performance of a dry and adiabatic fluid cooler
Miralles, M. L., Martínez, P., Cutillas, C. G., et al. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.04.033 · Cited by 11
“Following this idea, Hajidavalloo and Eghtedari [12] coupled an evaporative cooler to the existing air-cooled condenser of a split-air-conditioner.”
MethodSensitivity Analysis of Evaporative Condensers Performance Using an Experimental Approach
Fiorentino, M., & Starace, G. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.08.232 · Cited by 11
Logistic regression-based optimal control for air-cooled chiller
Yu, F. W., Ho, W. T., Chan, K. T., & Sit, R. K. Y. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.09.026 · Cited by 13
Hashim, R. H., Hammdi, S. H., & Eidan, A. A. (2023) · Open Engineering · doi:10.1515/eng-2022-0415 · Cited by 10
“Hajidavalloo and Eghtedari [15] demonstrated that when an evaporative cooler was attached to an AC’s condenser, the system could operate more efficiently, increasing its COP in a hot and dry environment by up to 50%, while consuming up to 20% less power.”
BackgroundWang, M., Hu, E. J., & Chen, L. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.108168 · Cited by 10
Juengjaroennirachon, S., Pratinthong, N., Namprakai, P., et al. (2017) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-016-1241-z · Cited by 10
“[6] applied the evaporatively-cooled air condenser rather than an air-cooled condenser to improve the performance of an air-cooled refrigeration system.”
BackgroundYu, F. W., Chan, K. T., Yang, R. J., & Sit, R. K. Y. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.12.036 · Cited by 11
Subcooling effect on air-conditioning system by simulation analysis
Karthik, R., Karthik, A. G., Karthik, A. G., et al. (2020) · Materials Today Proceedings · doi:10.1016/j.matpr.2020.06.310 · Cited by 9
ENERGY ANALYSIS OF A VAPOR COMPRESSION SYSTEM CASCADED WITH AMMONIA–WATER ABSORPTION SYSTEM
Sachdeva, G., Jain, V., & Kachhwaha, S. S. (2014) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132514500072 · Cited by 9
El‐Said, E. M. S., Hegazi, A. A., & Awad, A. M. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.103926 · Cited by 8
Puangcharoenchai, P., Kachapongkun, P., Rattanadecho, P., et al. (2020) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132520500182 · Cited by 8
Charoensin-O-Larn, R., Kavee, N., & Klinbun, J. (2024) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2024.104941 · Cited by 7
Research on the performance and application of spray cooling in the gas phase space
Liu, X., Liu, L., Liu, L., et al. (2025) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2025.103383 · Cited by 7
Bahman, A. M. (2025) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2025.104227 · Cited by 7
Wang, M., Hu, E. J., & Chen, L. (2023) · Energies · doi:10.3390/en16186506 · Cited by 7
Yang, Y., Zeng, J., Yang, B., Hu, J., & Zhang, Z. (2025) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2025.03.022 · Cited by 7
Metadata
- Authors
- Hajidavalloo, E., & Eghtedari, H.
- Affiliations
- Shahid Chamran University of Ahvaz (IR)
- Corresponding author
- Hajidavalloo, E.
- ORCID
- Hajidavalloo, E.
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 33
- Issue
- 5
- Pages
- 982-988
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W1984987217
- Semantic Scholar
- 493d9a54ed7c9afeb42677d8e3d87fe465a41cd8
- Cited by
- 174
- References
- 5
- Citations by year
- 2026: 11 · 2025: 10 · 2024: 8 · 2023: 13 · 2022: 13 · 2021: 16 · 2020: 12 · 2019: 14 · 2018: 19 · 2017: 13 · 2016: 11 · 2015: 10 · 2014: 6 · 2013: 7 · 2012: 8
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- International Journal of Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Keywords
- evaporative cooling, air-cooled condenser, split air conditioner, coefficient of performance, refrigeration cycle performance, ambient temperature effects, energy consumption reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.