The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a, R404A and R410A
Abstract
The current European F-gas regulation establishes restrictions in the use of fluoride refrigerants with a high global warming potential (GWP) in applications of refrigeration and air conditioning (RAC) systems. Moreover, a gradual limitation on the GWP weight of the fluoride refrigerants placed on the market is ongoing and will end with approximately one-fifth of today's offer. In this context, many of the RAC systems operate with refrigerants R134a, R404A, and R410A that have GWP values of 1300, 3943 and 2088, respectively, are being forced to be replaced by environmentally friendly alternatives, like hydrofluoroolefin (HFO) refrigerants and their mixtures with hydrofluorocarbons (HFC), which can be designed to present intermediate characteristics and become the ideal candidate many RAC applications. This work presents the most recent HFC/HFO/HC/R744 refrigerant mixture options for an alternative to the refrigerants mentiond above and compares their energetic and performance with the early developed mixture prototypes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lemmon, E. W., Huber, M. L., & McLinden, M. O. (2007) · Cited by 4,201
Natural and synthetic refrigerants, global warming: A review
Abas, N., Kalair, A. R., Khan, N., Haider, A., Saleem, Z., & Saleem, M. S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.099 · Cited by 486
The large contribution of projected HFC emissions to future climate forcing
Velders, G. J. M., Fahey, D. W., Daniel, J. S., McFarland, M., & Andersen, S. O. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902817106 · Cited by 424
A thermodynamic analysis of refrigerants: Possibilities and tradeoffs for Low-GWP refrigerants
McLinden, M. O., Kazakov, A. F., Steven Brown, J., & Domanski, P. A. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.09.032 · Cited by 388
Harby, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.039 · Cited by 249
Sarbu, I. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.04.023 · Cited by 202
Mota-Babiloni, A., Makhnatch, P., & Khodabandeh, R. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.06.026 · Cited by 182
Self-citationMota-Babiloni, A., Navarro-Esbrí, J., Makhnatch, P., & Molés, F. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.216 · Cited by 154
Self-citationScreening of working fluids for the ejector refrigeration system
Chen, J., Havtun, H., & Palm, B. E. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.07.016 · Cited by 118
Comprehensive investigation of transport refrigeration life cycle climate performance
Li, G. (2017) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2017.04.002 · Cited by 75
Saravanakumar, R., & Selladurai, V. (2013) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-013-3264-3 · Cited by 70
Abraham, J. D. A. P., & Mohanraj, M. P. (2018) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-018-7843-1 · Cited by 54
Lee, H., Hwang, Y., Song, I., & Jang, K. (2015) · Energy · doi:10.1016/j.energy.2015.07.016 · Cited by 52
Gaurav, G., & Kumar, R. (2018) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2018.01.002 · Cited by 44
Refrigerants used in the Portuguese food industry: Current status
Cardoso, B. J., LAMAS, F. M., Gaspar, A. R., & Ribeiro, J. B. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.07.013 · Cited by 39
Numerical research on R32/R1234ze(E) air source heat pump under variable mass concentration
Cheng, Z., Wang, B., Shi, W., & Li, X. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.06.014 · Cited by 37
Barrière, O., Behnassi, M., David, G., Douzal, V., Fargette, M., Libourel, T., Loireau, M., Pascal, L., Prost, C., Ravena Cañete, V., et al. (2019) · Springer eBooks · doi:10.1007/978-3-319-78111-2 · Cited by 30
Experimental investigations on R430A as a drop-in substitute for R134a in domestic refrigerators
Mohanraj, M. P. (2018) · Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering · doi:10.1177/0954408918796369 · Cited by 18
Abdelaziz, O. A., USDOE Office of Energy Efficiency and Renewable Energy (EERE), Shrestha, S., et al. (2016) · doi:10.2172/1326522 · Cited by 16
Low-GWP alternative refrigerant blends for HFC-134a
Domanski, P. A., McLinden, M. O., Bell, I. H., & Linteris, G. T. (2018) · doi:10.6028/nist.tn.2014 · Cited by 7
Cited by
Impacts of Global Climate Change on Agricultural Production: A Comprehensive Review
Yuan, X., Li, S., Chen, J., Yu, H., Yang, T., Wang, C., Huang, S., Chen, H., & Ao, X. (2024) · Agronomy · doi:10.3390/agronomy14071360 · Cited by 335
Tayefeh, A., Aslani, A., Zahedi, R., & Yousefi, H. (2024) · Cleaner Energy Systems · doi:10.1016/j.cles.2024.100124 · Cited by 20
Metadata
- Authors
- Heredia-Aricapa, Y., Belman-Flores, J. M., Mota-Babiloni, A., Serrano-Arellano, J., & García-Pabón, J. J.
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 111
- Pages
- 113-123
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2988343735
- Cited by
- 307
- References
- 20
- FWCI
- 19.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.