The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Variability of Target and Normal Structure Delineation for Breast Cancer Radiotherapy: An RTOG Multi-Institutional and Multiobserver Study
Open accessAbstract
Purpose To quantify the multi-institutional and multi-observer variability of target and organ-at-risk (OAR) delineation for breast-cancer radiotherapy (RT), and its dosimetric impacts, as the first step of a RTOG effort to establish a breast cancer atlas. Methods and Materials Nine radiation oncologists specializing in breast RT from eight institutions independently delineated targets (e.g., lumpectomy cavity, boost planning target volume, breast, supraclavicular, axillary and internal mammary nodes, and chest wall) and OARs (e.g., heart, lung) on the same CT images of three representative patients with breast cancer. Inter-observer differences in structure delineation were quantified with regard to volume, distance between centers of mass, percent overlap, and average surface distance. The mean, median and standard deviation for these quantities were calculated for all possible combinations. To asses the impact of these variations on treatment planning, representative dosimetric plans based on observer-specific contours were generated. Results The variability in contouring the targets and OARs between the institutions/observers was substantial. The structure overlaps were as low as 10% and the volume variations had standard deviations up to 60%. The large variability was related both to differences in opinion regarding target and OAR boundaries as well as approach to incorporation of setup uncertainty and dosimetric limitations in target delineation. These inter-observer differences result in substantial variations in dosimetric planning for breast RT. Conclusions The differences in target and OAR delineation for breast irradiation between institutions/observers appear to be clinically and dosimetrically significant. A systematic consensus is highly desirable, particularly in the era of IMRT/IGRT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fisher, B., Bauer, M., Margolese, R., Poisson, R., Pilch, Y., Redmond, C., Fisher, E., Wolmark, N., Deutsch, M., Montague, E., et al. (1985) · New England Journal of Medicine · doi:10.1056/nejm198503143121101 · Cited by 2,194
Fisher, B., Redmond, C., Poisson, R., Margolese, R., Wolmark, N., Wickerham, L., Fisher, E., Deutsch, M., Caplan, R., Pilch, Y., et al. (1989) · New England Journal of Medicine · doi:10.1056/nejm198903303201302 · Cited by 1,587
Definition of the prostate in CT and MRI: a multi-observer study
Rasch, C., Barillot, I., Remeijer, P., Touw, A., van Herk, M., & Lebesque, J. V. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00351-4 · Cited by 565
Fiorino, C., Reni, M., Bolognesi, A., Cattaneo, G. M., & Calandrino, R. (1998) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(98)00021-8 · Cited by 354
Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapy
Vicini, F. A., Sharpe, M., Kestin, L. L., Martinez, A. A., Mitchell, C. K., Wallace, M. F., Matter, R. C., & Wong, J. W. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)03746-x · Cited by 335
Self-citationVariability Among Breast Radiation Oncologists in Delineation of the Postsurgical Lumpectomy Cavity
Landis, D. M., Luo, W., Song, J., Bellon, J. R., Punglia, R. S., Wong, J. S., Killoran, J. H., Gelman, R., & Harris, J. R. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.11.026 · Cited by 213
Variability in target volume delineation on CT scans of the breast
Hurkmans, C. W., Borger, J. H., Pieters, B. R., Russell, N. S., Jansen, E. P. M., & Mijnheer, B. J. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01635-2 · Cited by 209
Senan, S., de Koste, J. R. V. S., Samson, M. J., Tankink, H., Jansen, P. P., Nowak, P. J. C. M., Krol, A. D. G., Schmitz, P. I. M., & Lagerwaard, F. J. (1999) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(99)00143-7 · Cited by 147
Petersen, R., Truong, P. T., Kader, H. A., Berthelet, E., Lee, J. C., Hilts, M., Kader, A. S., Beckham, W., & Olivotto, I. A. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.01.070 · Cited by 146
Weed, D. W., Yan, D., Martinez, A. A., Vicini, F. A., WILKINSON, T. J., & Wong, J. W. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.03.012 · Cited by 141
Self-citationLeunens, G., Menten, J. J., Weltens, C. G., Verstraete, J., & van der Schueren, E. (1993) · Radiotherapy and Oncology · doi:10.1016/0167-8140(93)90243-2 · Cited by 140
Tai, P., Dyk, J. V., Yu, E., Battista, J. J., Stitt, L., & Coad, T. (1998) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00216-8 · Cited by 111
Crook, J. M., Milosevic, M., Catton, P. A., Yeung, I. W. T., Rosewall, T., Tran, T. T., Catton, C., McLean, M., Panzarella, T., & Haider, M. A. (2002) · Brachytherapy · doi:10.1016/s1538-4721(02)00014-4 · Cited by 92
Consistency in seroma contouring for partial breast radiotherapy: Impact of guidelines
Wong, E. K., Truong, P. T., Kader, H. A., Nichol, A., Salter, L., Petersen, R., Wai, E. S., Weir, L. M., & Olivotto, I. A. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.05.066 · Cited by 87
Yamamoto, M., Nagata, Y., Okajima, K., Ishigaki, T., Murata, R., Mizowaki, T., Kokubo, M., & Hiraoka, M. (1999) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(99)00015-8 · Cited by 77
Quality Assurance in Radiotherapy of Breast Cancer Variability in Planning Target Volume Delineation
Pitkänen, K. A. H. M. A. (2001) · Acta Oncologica · doi:10.1080/028418601750071055 · Cited by 70
Morrow, N. V., Stepaniak, C., White, J. R., Wilson, J. F., & Li, X. A. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.06.056 · Cited by 63
Self-citationInverse vs. forward breast IMRT planning
Mihai, A., Rakovitch, E., Sixel, K. E., Woo, T. C. S., Cardoso, M., Bell, C., Ruschin, M., & Pignol, J. (2005) · Medical dosimetry · doi:10.1016/j.meddos.2005.03.004 · Cited by 51
Teh, B. S., Lu, H. H., Sobremonte, S., Bellezza, D., Chiu, J. K., Carpenter, L., Dennis, W. S., Woo, S. Y., & Butler, E. B. (2001) · The Breast Journal · doi:10.1046/j.1524-4741.2001.20036.x · Cited by 36
Cited by
Artificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
“In current clinical practice, tumors are typically manually defined, with associated limitations including interrater bias, 12 inconsistent reproducibility even among experts, 13,14 and consumption of time and labor.”
BackgroundOffersen, B. V., Boersma, L. J., Kirkove, C., Hol, S., Aznar, M. C., Biete Sola, A., Kirova, Y. M., Pignol, J.-P., Remouchamps, V., Verhoeven, K., et al. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2014.11.030 · Cited by 728
Feng, M., Moran, J. M., Koelling, T., Chughtai, A., Chan, J. L., Freedman, L., Hayman, J. A., Jagsi, R., Jolly, S., Larouere, J., et al. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.10.058 · Cited by 715
Self-citationCardenas, C. E., Yang, J., Anderson, B. M., Court, L. E., & Brock, K. B. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.001 · Cited by 407
Vision 20/20: Perspectives on automated image segmentation for radiotherapy
Sharp, G., Fritscher, K. D., Pekar, V., Peroni, M., Shusharina, N., Veeraraghavan, H., & Yang, J. (2014) · Medical Physics · doi:10.1118/1.4871620 · Cited by 375
Metadata
- Authors
- Li, X. A., Tai, A., Arthur, D. W., Buchholz, T. A., Macdonald, S., Marks, L. B., Moran, J. M., Pierce, L. J., Rabinovitch, R., Taghian, A., Vicini, F., Woodward, W., & White, J. R.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 73
- Issue
- 3
- Pages
- 944-951
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W1970483105
- Cited by
- 382
- References
- 19
- FWCI
- 19.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.