The DOI matches its Crossref record.
Radiotherapy Dose–Volume Effects on Salivary Gland Function
Open accessAbstract
Publications relating parotid dose-volume characteristics to radiotherapy-induced salivary toxicity were reviewed. Late salivary dysfunction has been correlated to the mean parotid gland dose, with recovery occurring with time. Severe xerostomia (defined as long-term salivary function of <25% of baseline) is usually avoided if at least one parotid gland is spared to a mean dose of less than ≈20 Gy or if both glands are spared to less than ≈25 Gy (mean dose). For complex, partial-volume RT patterns (e.g., intensity-modulated radiotherapy), each parotid mean dose should be kept as low as possible, consistent with the desired clinical target volume coverage. A lower parotid mean dose usually results in better function. Submandibular gland sparing also significantly decreases the risk of xerostomia. The currently available predictive models are imprecise, and additional study is required to identify more accurate models of xerostomia risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Langendijk, J. A., Lambin, P., De Ruysscher, D., Widder, J., Bos, M., & Verheij, M. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.05.007 · Cited by 549
Violet, J., Jackson, P., Ferdinandus, J., Sandhu, S., Akhurst, T., Iravani, A., Kong, G., Kumar, A. R., Thang, S. P., Eu, P., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.219352 · Cited by 504
Kabasakal, L., AbuQbeitah, M., Aygün, A., Yeyin, N., Ocak, M., Demirci, E., & Toklu, T. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3125-3 · Cited by 208
Peters, S. M. B., Privé, B. M., de Bakker, M., de Lange, F., Jentzen, W., Eek, A., Muselaers, C. H. J., Mehra, N., Witjes, J. A., Gotthardt, M., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05471-4 · Cited by 88
Metadata
- Authors
- Deasy, J. O., Moiseenko, V., Marks, L., Chao, K. S. C., Nam, J., & Eisbruch, A.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 76
- Issue
- 3
- Pages
- S58-S63
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W2005574374
- Cited by
- 590
- References
- 0
- FWCI
- 21.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiotherapy Dose–Volume Effects on Salivary Gland Function. https://app.cochat.ai/papers/10.1016/j.ijrobp.2009.06.090
- The paper
- Deasy, J. O., Moiseenko, V., Marks, L., Chao, K. S. C., Nam, J., & Eisbruch, A. (2010). Radiotherapy Dose–Volume Effects on Salivary Gland Function. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2009.06.090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.