What Is the Best Way to Contour Lung Tumors on PET Scans? Multiobserver Validation of a Gradient-Based Method Using a NSCLC Digital PET Phantom

Open access
Werner-Wasik, Maria, Nelson, Arden D., Choi, Walter, Arai, Yoshio, Faulhaber, Peter F., Kang, Patrick, Almeida, Fabio D., Xiao, Ying, Ohri, Nitin, Brockway, Kristin D., Piper, Jonathan W., Nelson, Aaron S. · 2012 · International Journal of Radiation Oncology*Biology*Physics

Abstract

Purpose To evaluate the accuracy and consistency of a gradient-based PET segmentation method, GRADIENT, as compared to manual (MANUAL) and constant threshold (THRESHOLD) methods. Methods and Materials Contouring accuracy was evaluated with sphere phantoms and clinically realistic Monte Carlo PET phantoms of the thorax. The sphere phantoms were 10–37 mm in diameter and were acquired at 5 institutions emulating clinical conditions. One institution also acquired a sphere phantom with multiple source-to-background ratios (SBR) of 2:1, 5:1, 10:1, 20:1, and 70:1. One observer segmented (contoured) each sphere with GRADIENT and THRESHOLD from 25–50% at 5% increments. Subsequently, seven physicians segmented lessions (7–264ml) from 25 digital thorax phantoms using GRADIENT, THRESHOLD, and MANUAL. Results For spheres < 20 mm in diameter, GRADIENT was the most accurate with a mean absolute %error in diameter of 8.15% (10.2%SD) compared to 49.2% (51.1%SD) for 45% THRESHOLD (p < 0.005). For larger spheres the methods were statistically equivalent. For varying SBR, GRADIENT was the most accurate for spheres > 20 mm, (p < 0.065) and < 20 mm (p < 0.015). For digital thorax phantoms, GRADIENT was the most accurate, (p-value < 0.01), with a mean absolute %error in volume of 10.99% (11.9%SD) followed by 25% THRESHOLD at 17.5% (29.4%SD), and MANUAL, at 19.5% (17.2%SD). GRADIENT had the least systematic bias, 4 with a mean %error in volume of −0.05% (16.2%SD) compared with 25% THRESHOLD at - 2.1% (34.2%SD) and MANUAL at −16.3% (20.2%SD) (p-value < 0.01). Inter-observer variability was reduced using GRADIENT compared to both 25% THRESHOLD and MANUAL (p-value < 0.01, Levene's Test). Conclusion GRADIENT was the most accurate and consistent technique for target volume contouring. GRADIENT was also the most robust for varying imaging conditions. GRADIENT has the potential to play an important role for tumor delineation in radiation therapy planning and response assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijrobp.2010.12.055

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 214

Metadata

Authors
Werner-Wasik, M., Nelson, A. D., Choi, W., Arai, Y., Faulhaber, P. F., Kang, P., Almeida, F. D., Xiao, Y., Ohri, N., Brockway, K. D., Piper, J. W., & Nelson, A. S.
Venue
International Journal of Radiation Oncology*Biology*Physics
Publisher
Elsevier BV
Published
2012-03
Volume
82
Issue
3
Pages
1164-1171
ISSN
0360-3016 (ISSN-L)
OpenAlex
W2012002553
Cited by
214
References
0
FWCI
15.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: What Is the Best Way to Contour Lung Tumors on PET Scans? Multiobserver Validation of a Gradient-Based Method Using a NSCLC Digital PET Phantom. https://app.cochat.ai/papers/10.1016/j.ijrobp.2010.12.055
The paper
Werner-Wasik, M., Nelson, A. D., Choi, W., Arai, Y., Faulhaber, P. F., Kang, P., Almeida, F. D., Xiao, Y., Ohri, N., Brockway, K. D., Piper, J. W., & Nelson, A. S. (2012). What Is the Best Way to Contour Lung Tumors on PET Scans? Multiobserver Validation of a Gradient-Based Method Using a NSCLC Digital PET Phantom. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2010.12.055

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.