The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparison and Consensus Guidelines for Delineation of Clinical Target Volume for CT- and MR-Based Brachytherapy in Locally Advanced Cervical Cancer
Open accessAbstract
Purpose/Objective To create and compare consensus clinical target volume (CTV) contours for computed tomography (CT) and 3 Tesla (3T) magnetic resonance (MR) image-based cervical-cancer brachytherapy Materials/Methods Twenty-three gynecologic radiation oncology experts contoured the same 3 cervical-cancer brachytherapy cases: one Stage IIB near-complete response (CR) case with a tandem and ovoid, one Stage IIB partial response (PR) case with ovoid with needles and one Stage IB2 CR case with a ring applicator. CT contours were completed before MRI contours. These were analyzed for consistency and clarity of target delineation using an expectation maximization algorithm for simultaneous truth and performance level estimation (STAPLE), with kappa statistics as a measure of agreement between participants. The conformity index (CI) was calculated for each of the six data sets. Dice coefficients were generated to compare CT and MR contours of the same case. Results For all 3 cases, the mean tumor volume was smaller on MR than on CT (p<0.001). Kappa and CI estimates were slightly higher for CT, indicating a higher level of agreement on CT. DICE coefficients were 89% for the Stage IB2 case with a CR, 74% for the Stage IIB case with a PR, and 57% for the Stage IIB case with a CR. Conclusion When comparing MR- to CT-contoured CTV volumes, the higher level of agreement on CT may be due to the more distinct contrast visible on the images at the time of brachytherapy. The largest difference at the time of brachytherapy was in the case with parametrial extension at diagnosis that had a near-complete response, due to the appearance of the parametria on CT but not on MR. Based on these results, a 95% consensus volume was generated for CT and for MR. Online contouring atlases are available for instruction at http://www.nrgoncology.org/Resources/ContouringAtlases.aspx.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
Cited by
Vinod, S. K., Jameson, M. G., Min, M., & Holloway, L. C. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.09.009 · Cited by 350
Metadata
- Authors
- Viswanathan, A. N., Erickson, B., Gaffney, D. K., Beriwal, S., Bhatia, S. K., Lee Burnett, O., D'Souza, D. P., Patil, N., Haddock, M. G., Jhingran, A., Jones, E. L., Kunos, C. A., Lee, L. J., Lin, L. L., Mayr, N. A., Petersen, I., Petric, P., Portelance, L., Small, W., Strauss, J. B., Townamchai, K., Wolfson, A. H., Yashar, C. M., & Bosch, W.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 2014-10
- Volume
- 90
- Issue
- 2
- Pages
- 320-328
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W2060343400
- Cited by
- 187
- References
- 1
- FWCI
- 15.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.