The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology
Open accessAbstract
The integration of adaptive radiation therapy (ART), or modifying the treatment plan during the treatment course, is becoming more widely available in clinical practice. ART offers strong potential for minimizing treatment-related toxicity while escalating or de-escalating target doses based on the dose to organs at risk. Yet, ART workflows add complexity into the radiation therapy planning and delivery process that may introduce additional uncertainties. This work sought to review presently available ART workflows as well as technological considerations such as image quality, deformable image registration, and dose accumulation. Quality assurance considerations for ART components and minimum recommendations are described. Personnel and workflow efficiency recommendations are provided as well as a summary of currently available clinical evidence supporting the implementation of ART. Finally, to guide future clinical trial protocols, an example ART physician directive and a physics template following standard NRG Oncology protocol is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881 · cited 2×
“Several studies have explored this approach,(51,79) and TG-132 also provided data sets created from ImSimQA software and recommended commercial DIR software vendors to provide feasible tools for user validation.(80) TG-132 provides guidelines for DIR evaluation metrics such as setting the tolerance of point-wise regis…”
MethodYan, D., Vicini, F., Wong, J., & Martinez, A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/008 · Cited by 761
Sturdza, A., Pötter, R., Fokdal, L. U., Haie-Meder, C., Tan, L. T., Mazeron, R., Petric, P., Šegedin, B., Jurgenliemk-Schulz, I. M., Nomden, C., et al. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.03.011 · Cited by 715
Adaptive radiotherapy: The Elekta Unity MR-linac concept
Winkel, D., Bol, G. H., Kroon, P. S., van Asselen, B., Hackett, S. S., Werensteijn-Honingh, A. M., Intven, M. P. W., Eppinga, W. S. C., Tijssen, R. H. N., Kerkmeijer, L. G. W., et al. (2019) · Clinical and Translational Radiation Oncology · doi:10.1016/j.ctro.2019.04.001 · Cited by 572
Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge
Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2158349 · Cited by 440
Respiration tracking in radiosurgery
Schweikard, A., Shiomi, H., & Adler, J. (2004) · Medical Physics · doi:10.1118/1.1774132 · Cited by 339
A survey of medical image registration – under review
Viergever, M. A., Maintz, J. B. A., Klein, S., Murphy, K., Staring, M., & Pluim, J. P. W. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.030 · Cited by 318
Bohoudi, O., Bruynzeel, A. M. E., Senan, S., Cuijpers, J. P., Slotman, B. J., Lagerwaard, F. J., & Palacios, M. A. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.07.028 · Cited by 318
Metadata
- Authors
- Glide-Hurst, C. K., Lee, P., Yock, A. D., Olsen, J. R., Cao, M., Siddiqui, F., Parker, W., Doemer, A., Rong, Y., Kishan, A. U., Benedict, S. H., Li, X. A., Erickson, B. A., Sohn, J. W., Xiao, Y., & Wuthrick, E.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 2021-03
- Volume
- 109
- Issue
- 4
- Pages
- 1054-1075
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W3094399418
- Cited by
- 317
- References
- 55
- FWCI
- 18.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology. https://app.cochat.ai/papers/10.1016/j.ijrobp.2020.10.021
- The paper
- Glide-Hurst, C. K., Lee, P., Yock, A. D., Olsen, J. R., Cao, M., Siddiqui, F., Parker, W., Doemer, A., Rong, Y., Kishan, A. U., Benedict, S. H., Li, X. A., Erickson, B. A., Sohn, J. W., Xiao, Y., & Wuthrick, E. (2021). Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2020.10.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.