Tumor Control Probability of Radiosurgery and Fractionated Stereotactic Radiosurgery for Brain Metastases

Redmond, Kristin J., Gui, Chengcheng, Benedict, Stanley, Milano, Michael T., Grimm, Jimm, Vargo, J. Austin, Soltys, Scott G., Yorke, Ellen, Jackson, Andrew, El Naqa, Issam, Marks, Lawrence B., Xue, Jinyu, Heron, Dwight E., Kleinberg, Lawrence R. · 2021 · International Journal of Radiation Oncology*Biology*Physics
Cited by 173

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

PURPOSE As part of the American Association of Physicists in Medicine Working Group on Stereotactic Body Radiotherapy, tumor control probability (TCP) after stereotactic radiosurgery (SRS) and fractionated stereotactic radiosurgery (fSRS) for brain metastases was modeled based on pooled dosimetric and clinical data from published English-language literature. METHODS AND MATERIALS PubMed-indexed studies published between January 1995 and September 2017 were used to evaluate dosimetric and clinical predictors of TCP after SRS or fSRS for brain metastases. Eligible studies had ≥10 patients and included detailed dose-fractionation data with corresponding ≥1-year local control (LC) data, typically evaluated as a >20% increase in diameter of the targeted lesion using the pre-SRS diameter as a reference. RESULTS Of 2951 potentially eligible manuscripts, 56 included sufficient dose-volume data for analyses. Accepting that necrosis and pseudoprogression can complicate the assessment of LC, for tumors ≤20 mm, single-fraction doses of 18 and 24 Gy corresponded with >85% and 95% 1-year LC rates, respectively. For tumors 21 to 30 mm, an 18 Gy single-fraction dose was associated with 75% LC. For tumors 31 to 40 mm, a 15 Gy single-fraction dose yielded ∼69% LC. For 3- to 5-fraction fSRS using doses in the range of 27 to 35 Gy, 80% 1-year LC has been achieved for tumors of 21 to 40 mm in diameter. CONCLUSIONS TCP for SRS and fSRS are presented. For small lesions ≤20 mm, single doses of ≈18 Gy appear generally associated with excellent rates of LC; for melanoma, higher doses seem warranted. For larger lesions >20 mm, local control rates appear to be ≈ 70% to 75% with usual doses of 15 to 18 Gy, and in this setting, fSRS regimens should be considered. Greater consistency in reporting of dosimetric and LC data is needed to facilitate future pooled analyses. As systemic and biologic therapies evolve, updated analyses will be needed to further assess the necessity, efficacy, and toxicity of SRS and fSRS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijrobp.2020.10.034

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 44 references

Metadata

Authors
Redmond, K. J., Gui, C., Benedict, S., Milano, M. T., Grimm, J., Vargo, J. A., Soltys, S. G., Yorke, E., Jackson, A., El Naqa, I., Marks, L. B., Xue, J., Heron, D. E., & Kleinberg, L. R.
Venue
International Journal of Radiation Oncology*Biology*Physics
Publisher
Elsevier BV
Published
2021-05
Volume
110
Issue
1
Pages
53-67
ISSN
0360-3016 (ISSN-L)
OpenAlex
W3114349612
Cited by
173
References
44
FWCI
8.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tumor Control Probability of Radiosurgery and Fractionated Stereotactic Radiosurgery for Brain Metastases. https://app.cochat.ai/papers/10.1016/j.ijrobp.2020.10.034
The paper
Redmond, K. J., Gui, C., Benedict, S., Milano, M. T., Grimm, J., Vargo, J. A., Soltys, S. G., Yorke, E., Jackson, A., El Naqa, I., Marks, L. B., Xue, J., Heron, D. E., & Kleinberg, L. R. (2021). Tumor Control Probability of Radiosurgery and Fractionated Stereotactic Radiosurgery for Brain Metastases. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2020.10.034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.