Analysis of thermal comfort and indoor air flow characteristics for a residential building room under generalized window opening position at the adjacent walls
Open accessAbstract
Thermal comfort is an imperative factor that determines the health and productivity of the occupants living in residential buildings. The growing health related symptoms and demand for the electrical energy encourage the occupants to switch over to natural ventilation. Thermal comfort for naturally ventilated buildings mainly depends on the size and orientation of window openings. Even though most research works include the study on indoor thermal comfort for various positions of window opening it was limited to single sided and cross ventilated buildings. In real situation most of the rooms attached to the residential buildings are having window openings at their adjacent wall and hence this paper was focused to study the occupants’ thermal comfort and indoor air flow characteristics for a room with adjacent window openings under generalized approach. Computational fluid dynamics (CFD) technique is employed to study the indoor air flow for a three-dimensional room model. The CFD simulation is checked for grid independence and having good validation with experimental measurements on the reduced scale model at wind tunnel and with the network model with the k–ε turbulence model. Air temperatures along various midlines, planes, areas occupied by low temperature zone and predicted mean vote (PMV) contours are presented in this paper. From this study a new set of strategies are identified to locate the window openings and the best location improves percentage of low temperature by 50%, reduces the PMV and PPD by 0.12% and 3.51%, respectively with reference to the worst window opening position.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“But their use may result in loss of air pressure across the screen [31] and found to result in 7 % reduction in the ventilation rate through the vent pipe if all other factors are held constant [32].”
From Compliance of private ventilated improved pit latrines to odour and fly control guidelines: A technical audit in selected regions of Ghana (2024) · cites this paper as [31]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 43
- Allocca, 2003, Design analysis of single – sided natural ventilation, Energy Build., 35, 785, 10.1016/S0378-7788(02)00239-6 · DOI
- Asfour, 2007, A comparison between CFD and network models for predicting wind-driven ventilation in buildings, Build. Environ., 42, 4079, 10.1016/j.buildenv.2006.11.021 · DOI
- Caciolo, 2011, Full scale experimental study of single-sided ventilation: analysis of stack and wind effects, Energy Build., 43, 1765, 10.1016/j.enbuild.2011.03.019 · DOI
- Caciolo, 2012, Numerical simulation of single-sided ventilation using RANS and LES and comparison with full-scale experiments, Build. Environ., 50, 202, 10.1016/j.buildenv.2011.10.017 · DOI
- Chen, 2004, Using computational tools to factor wind into architectural environmental design, Energy Build., 36, 1197, 10.1016/j.enbuild.2003.10.013 · DOI
- Dascalaki, 1995, Predicting single sided natural ventilation rates in buildings, Solar Energy, 5, 327, 10.1016/0038-092X(95)00057-X · DOI
- Eftekhari, 2003, Air flow distribution in and around a single-sided naturally ventilated room, Build. Environ., 38, 389, 10.1016/S0360-1323(02)00016-1 · DOI
- Evalo, 2006, Computational analysis of wind driven natural ventilation in buildings, Energy Build., 38, 491, 10.1016/j.enbuild.2005.08.008 · DOI
- Favarolo, 2005, Temperature-driven single-sided ventilation through a large rectangular opening, Build. Environ., 40, 689, 10.1016/j.buildenv.2004.08.003 · DOI
- Gao, 2011, Evaluating the influence of openings configuration on natural ventilation performance of residential units in Hong Kong, Build. Environ., 46, 961, 10.1016/j.buildenv.2010.10.029 · DOI
- Hassana, 2007, Investigation of effects of window combinations on ventilation characteristics for thermal comfort in buildings, Desalination, 209, 251, 10.1016/j.desal.2007.04.035 · DOI
- Hoang, 2000, Analysis of the air flow in a cold store by means of computational fluid dynamics, Int J Refrig., 23, 127, 10.1016/S0140-7007(99)00043-2 · DOI
- Hooff, 2012, Numerical analysis of the performance of a venturi-shaped roof for natural ventilation: influence of building width, J. Wind Eng. Ind. Aerodyn., 104–106, 419, 10.1016/j.jweia.2012.02.013 · DOI
- Hu, 2008, CFD modelling of unsteady cross ventilation flows using LES, J. Wind Eng. Ind. Aerodyn., 96, 1692, 10.1016/j.jweia.2008.02.031 · DOI
- Huo, 2000, A systematic approach to describe the air terminal device in CFD simulation for room air distribution analysis, Build. Environ., 35, 563, 10.1016/S0360-1323(99)00047-5 · DOI
- Ji, 2011, Wind tunnel investigation on influence of fluctuating wind direction on cross natural ventilation, Build. Environ., 46, 2490, 10.1016/j.buildenv.2011.06.006 · DOI
- Karava, 2011, Wind-induced internal pressures in buildings with large facade openings, J. Eng. Mech. ASCE
- Karava, 2011, Airflow assessment in cross-ventilated buildings with operable façade elements, Build. Environ., 46, 266, 10.1016/j.buildenv.2010.07.022 · DOI
- Kato, 1992, Velocity-pressure field of cross ventilation with open windows analyzed by wind tunnel and numeric simulation, J. Wind Eng. Ind. Aerodyn., 41–44, 2575, 10.1016/0167-6105(92)90049-G · DOI
- Koinakis, 2005, Combined thermal and natural ventilation modelling for long-term energy assessment: validation with experimental measurements, Energy Build., 37, 311, 10.1016/j.enbuild.2004.06.022 · DOI
- Larsena, 2011, Characterization and prediction of the volume flow rate aerating a cross ventilated building by means of experimental techniques and numerical approaches, Energy Build., 43, 1371, 10.1016/j.enbuild.2011.01.015 · DOI
- Launder, 1974, The numerical computation of turbulent flows, Comp. Methods Appl. Mech. Eng., 3, 269, 10.1016/0045-7825(74)90029-2 · DOI
- Lo, 2012, Cross ventilation with small openings: measurements in a multi-zone test building, Build. Environ., 57, 377, 10.1016/j.buildenv.2012.06.009 · DOI
- Lo, 2013, Effect of indoor buoyancy flow on wind-driven cross ventilation, Build. Simulation, 6, 69, 10.1007/s12273-012-0094-3 · DOI
- Lo, 2013, Combined wind tunnel and CFD analysis for indoor airflow prediction of wind-driven cross ventilation, Build. Environ., 60, 12, 10.1016/j.buildenv.2012.10.022 · DOI
- Montazeri, 2013, CFD simulation of wind-induced pressure coefficients on buildings with and without balconies: validation and sensitivity analysis, Build. Environ., 60, 137, 10.1016/j.buildenv.2012.11.012 · DOI
- Nikolopoulos, 2012, Experimental and numerical investigation of the tracer gas methodology in the case of a naturally cross-ventilated building, Build. Environ., 56, 379, 10.1016/j.buildenv.2012.04.006 · DOI
- Posner, 2003, Measurement and prediction of indoor air flow in a model room, Energy Build., 35, 515, 10.1016/S0378-7788(02)00163-9 · DOI
- Ramponi, 2012, CFD simulation of cross-ventilation flow for different isolated building configurations: validation with wind tunnel measurements and analysis of physical and numerical diffusion effects, J. Wind Eng. Ind. Aerodyn., 104–106, 408, 10.1016/j.jweia.2012.02.005 · DOI
- Ravikumar, 2009, Analysis of thermal comfort in an office room by varying the dimensions of the windows on adjacent walls using CFD: a case study based on numerical simulation, Build. Simulation, 2, 187, 10.1007/s12273-009-9317-7 · DOI
- Rouaud, 2002, Computation of the airflow in a pilot scale clean room using k–ε turbulence models, Int. J. Refrig., 25, 351, 10.1016/S0140-7007(01)00014-7 · DOI
- Seifert, 2006, Calculation of wind-driven cross ventilation in buildings with large openings, J. Wind Eng. Ind. Aerodyn., 94, 925, 10.1016/j.jweia.2006.04.002 · DOI
- Song, 2003, Radiational panel cooling system with continuous natural cross ventilation for hot and humid regions, Energy Build., 36, 1273, 10.1016/j.enbuild.2003.07.004 · DOI
- Stavrakakis, 2008, Natural cross-ventilation in buildings: building-scale experiments, numerical simulation and thermal comfort evaluation, Energy Build., 40, 1666, 10.1016/j.enbuild.2008.02.022 · DOI
- Stavrakakis, 2012, Optimization of window-openings design for thermal comfort in naturally ventilated buildings, Appl. Math. Model., 36, 193, 10.1016/j.apm.2011.05.052 · DOI
- Straw, 2000, Experimental measurements and computations of the wind-induced ventilation of a cubic structure, J. Wind Eng. Ind. Aerodyn., 88, 213, 10.1016/S0167-6105(00)00050-7 · DOI
- Versteeg, H.G., Malalasekera, W., 1995. An Introduction to Computational Fluid dynamics: The Finite Volume Method Approach. Wiley, New York.
- Visagavel, 2009, Analysis of single side ventilated and cross ventilated rooms by varying the width of the window opening using CFD, Solar Energy, 83, 2, 10.1016/j.solener.2008.06.004 · DOI
- Walker, 1992, Single sided natural ventilation-how deep an office, Build. Serv. Eng. Res. Technol., 13, 231, 10.1177/014362449201300407 · DOI
- Wong, 2004, The study of active stack effect to enhance natural ventilation using wind tunnel and computational fluid dynamics (CFD) simulations, Energy Build., 36, 668, 10.1016/j.enbuild.2004.01.013 · DOI
- Yang, 2006, A comparison of CFD and full-scale measurement for analysis of natural ventilation, Int. J. Ventil., 4, 337, 10.1080/14733315.2005.11683713 · DOI
- Zeidler, O., Fitzner, K., 1997. Investigation of the impact of natural ventilation through windows on the thermal comfort. Proc. Clima 2000, Brussels.
- Zhen, 2011, Wind-induced ventilation performances and airflow characteristics in an areaway-attached basement with a single-sided opening, Build. Environ., 46, 911, 10.1016/j.buildenv.2010.10.019 · DOI
Cited by
Sorted by citations
Obeng, P. A., Donkor, E. A., Awere, E., Oduro-Kwarteng, S., Obeng, P. A., & Awuah, E. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e33980 · Cited by 6
“But their use may result in loss of air pressure across the screen [31] and found to result in 7 % reduction in the ventilation rate through the vent pipe if all other factors are held constant [32].”
Background
Metadata
- Authors
- Prakash, D., & Ravikumar, P.
- Affiliations
- SASTRA University (IN)
- Corresponding author
- Prakash, D.
- Venue
- International Journal of Sustainable Built Environment
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 4
- Issue
- 1
- Pages
- 42-57
- ISSN
- 2212-6090 (ISSN-L)
- OpenAlex
- W2038354687
- Cited by
- 64
- References
- 0
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 10 · 2023: 7 · 2022: 10 · 2021: 8 · 2020: 9 · 2019: 7 · 2018: 1 · 2017: 4 · 2016: 2
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- International Journal of Sustainable Built Environment (publishedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
- Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
- Keywords
- thermal comfort, natural ventilation, indoor airflow, residential buildings, predicted mean vote, k-epsilon turbulence model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of thermal comfort and indoor air flow characteristics for a residential building room under generalized window opening position at the adjacent walls. https://app.cochat.ai/papers/10.1016/j.ijsbe.2015.02.003
- The paper
- Prakash, D., & Ravikumar, P. (2015). Analysis of thermal comfort and indoor air flow characteristics for a residential building room under generalized window opening position at the adjacent walls. International Journal of Sustainable Built Environment. https://doi.org/10.1016/j.ijsbe.2015.02.003