A sensor fusion approach for drowsiness detection in wearable ultra-low-power systems
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a pilot study (n = 10), a single-channel electroencephalogram and IMU sensor detected five different levels of drowsiness with an average of 95.2% accuracy.
“To explore the use of wearable devices to detect drowsiness, one recent pilot study (n = 10) used a single-channel electroencephalogram and IMU sensor to detect five different levels of drowsiness with an average of 95.2% accuracy [91].”
From Wearables and the Medical Revolution (2018) · cites this paper as [91]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 72 · Cited by 69
Research works printed but not linked: 3
- Q. Ji, Z. Zhu, P. Lan, Real-time nonintrusive monitoring and prediction of driver fatigue, IEEE transactions on vehicular tech- nology 53 (4) (2004) 1052-1068.
- A. Rahman, et al., Real time drowsiness detection using eye blink monitoring, in: NSEC, IEEE, 2015, pp. 1-7.
- J. Xu, R. F. Yazicioglu, B. Grundlehner, P. Harpe, K. A. A. Mak- inwa, C. V. Hoof, A 160uw 8-channel active electrode system for eeg monitoring, IEEE Transactions on Biomedical Circuits and Systems 5 (6) (2011) 555-567.
- Authors
- Kartsch, V. J., Benatti, S., Schiavone, P. D., Rossi, D., & Benini, L.
- Affiliations
- University of Bologna (IT)
- ETH Zurich (CH)
- Corresponding author
- Kartsch, Victor Javier
- Venue
- Information Fusion
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 43
- Pages
- 66-76
- ISSN
- 1566-2535 (ISSN-L)
- OpenAlex
- W2770426008
- Cited by
- 69
- References
- 72
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 9 · 2022: 11 · 2021: 10 · 2020: 18 · 2019: 8 · 2018: 5
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (am, 91 d)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- Information Fusion (acceptedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion, cc-by-nc-nd)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- Funders
- Swiss National Science Foundation (162524)
- ERC (ERC-AdG-291125)
- European Union’s Horizon 2020 research and innovation programme (732631)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and Work-Related Fatigue
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- drowsiness detection, sensor fusion, wearable devices, ultra-low-power systems, EEG, inertial measurement unit, motion sensing, ARM Cortex-M4, energy optimization, battery life
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review