Improvement in automatic generation control of two-area electric power systems via a new fuzzy aided optimal PIDN-FOI controller
The DOI matches its Crossref record.
Abstract
Automatic generation control (AGC) executes a vital role to supply quality power in an interconnected power system. To cultivate good quality of power supply via preserving area frequency and tie-line power oscillations following consumer's load demand disturbances, the controller designed for AGC of power system should display excellent disturbance rejection expertise. Hence, in this paper, a maiden attempt is made to propose a fuzzy aided integer order proportional integral derivative with filter-fractional order integral (FPIDN-FOI) controller for AGC of multi-area power systems. A more recent intelligent optimization technique termed as imperialist competitive algorithm (ICA) is fruitfully employed for concurrent tuning of various parameters of the proposed controller. It is observed from the simulation results that the proposed FPIDN-FOI controller outperforms the various existing control strategies and PID/PIDN/FPIDN controller designed in the study for five different power system models. Effect of variation in fractional order value of integral on the system performance is analyzed. A sensitivity analysis is conducted to test the robustness of the designed controller under variations in the system parameters, load demands and existence of the system nonlinearities. It is perceived that the proposed controller is robust and executes adequately under variations in system parameters, random load disturbance patterns and nonlinearities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kalyan, C. N. S., Goud, B. S., Reddy, C. R., Bajaj, M., Sharma, N. K., Alhelou, H. H., Siano, P., & Kamel, S. (2022) · Energies · doi:10.3390/en15020629 · Cited by 78
“Previous research has employed searching approaches such as the bacterial foraging optimizer (BFO) [15], firefly pattern search (FA-PS) [16], symbiotic organism search (SOS) [17], imperialist competitive approach (ICA) [18], etc.”
BackgroundMethodKumar, R., & Sharma, V. K. (2021) · International Journal of Numerical Modelling: Electronic Networks, Devices and Fields · doi:10.1002/jnm.2802 · Cited by 14
Metadata
- Authors
- Arya, Y.
- Venue
- ISA Transactions
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 80
- Pages
- 475-490
- ISSN
- 0019-0578 (ISSN-L)
- OpenAlex
- W2887032851
- Cited by
- 169
- References
- 0
- FWCI
- 7.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improvement in automatic generation control of two-area electric power systems via a new fuzzy aided optimal PIDN-FOI controller. https://app.cochat.ai/papers/10.1016/j.isatra.2018.07.028
- The paper
- Arya, Y. (2018). Improvement in automatic generation control of two-area electric power systems via a new fuzzy aided optimal PIDN-FOI controller. ISA Transactions. https://doi.org/10.1016/j.isatra.2018.07.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.