CoChat

Non-Invasive Visualization of the Cardiac Venous System in Coronary Artery Disease Patients Using 64-Slice Computed Tomography

Open access
Van de Veire, Nico R., Schuijf, Joanne D., De Sutter, Johan, Devos, Dan, Bleeker, Gabe B., de Roos, Albert, van der Wall, Ernst E., Schalij, Martin J., Bax, Jeroen J. · 2006 · Journal of the American College of Cardiology
Cited by 207

The DOI matches its Crossref record.

Abstract

OBJECTIVES This study was designed to evaluate the value of 64-slice computed tomography (CT) to visualize the cardiac veins and evaluate the relation between variations in venous anatomy and history of infarction. BACKGROUND Cardiac resynchronization therapy (CRT) is an attractive treatment for selected heart failure patients. Knowledge of venous anatomy may help in identifying candidates for successful left ventricular lead implantation. METHODS The 64-slice CT of 100 individuals (age 61 +/- 11 years, 68% men) was studied. Subjects were divided into 3 groups: 28 control patients, 38 patients with significant coronary artery disease (CAD), and 34 patients with a history of infarction. Presence of the following coronary sinus (CS) tributaries was evaluated: posterior interventricular vein (PIV), posterior vein of the left ventricle, and left marginal vein (LMV). Vessel diameters were also measured. RESULTS Coronary sinus and PIV were identified in all individuals. Posterior vein of the left ventricle was observed in 96% of control patients, 84% of CAD patients, and 82% of infarction patients. In patients with a history of infarction, a LMV was significantly less observed as compared with control patients and CAD patients (27% vs. 71% and 61%, respectively, p < 0.001). None of the patients with lateral infarction and only 22% of patients with anterior infarction had a LMV. Regarding quantitative data, no significant differences were observed between the groups. CONCLUSIONS Non-invasive evaluation of cardiac veins with 64-slice CT is feasible. There is considerable variation in venous anatomy. Patients with a history of infarction were less likely to have a LMV, which may hamper optimal left ventricular lead positioning in CRT implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2006.07.042

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Van de Veire, N. R., Schuijf, J. D., De Sutter, J., Devos, D., Bleeker, G. B., de Roos, A., van der Wall, E. E., Schalij, M. J., & Bax, J. J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2006-11
Volume
48
Issue
9
Pages
1832-1838
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2157174194
Cited by
207
References
0
FWCI
13.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.