Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record.

Angiographic Surrogate End Points in Drug-Eluting Stent Trials

Open access
Pocock, Stuart J., Lansky, Alexandra J., Mehran, Roxana, Popma, Jeffrey J., Fahy, Martin P., Na, Yingbo, Dangas, George, Moses, Jeffrey W., Pucelikova, Tereza, Kandzari, David E., Ellis, Stephen G., Leon, Martin B., Stone, Gregg W. · 2008 · Journal of the American College of Cardiology

Abstract

OBJECTIVES We sought to validate 4 angiographic measures as potential surrogates for clinical restenosis (target lesion revascularization [TLR]) after stent implantation. BACKGROUND Given the low revascularization rates with drug-eluting stents (DES), an angiographic surrogate of TLR is desirable to reduce the sample size required to demonstrate efficacy in future trials of antirestenosis devices. METHODS We evaluated 4 potential angiographic measures (late loss [LL] and percent diameter stenosis [%DS], both in-stent and in-segment) as a surrogate for TLR at 1 year. From 11 multicenter, prospective randomized stent trials, 9 comparing DES with bare-metal stents (BMS) and 2 comparing different DES, individual data on 5,381 patients with a single treated lesion and follow-up angiography at 6 to 9 months were analyzed. RESULTS By 4 well-defined criteria of surrogacy, LL and %DS strongly predicted the risk of TLR, with in-segment %DS being the most highly predictive (approximately 0.95). Differences in TLR risk were fully explained statistically by their differences in LL or %DS, although LL as a surrogate was dependent on vessel size whereas %DS was not. However, because of the curvilinearity of the logistic model, trials comparing 2 effective DES can have significant differences in mean LL and %DS but small expected differences in TLR risk, especially at the lower ranges of LL and %DS. CONCLUSIONS From in-stent and in-segment LL and %DS measures, logistic models can reliably estimate TLR rates for DES and BMS. These angiographic measures are thus suitable surrogate markers for clinical stent efficacy and can be used as primary end points in future DES trials to significantly reduce sample size.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2007.07.084

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Pocock, S. J., Lansky, A. J., Mehran, R., Popma, J. J., Fahy, M. P., Na, Y., Dangas, G., Moses, J. W., Pucelikova, T., Kandzari, D. E., Ellis, S. G., Leon, M. B., & Stone, G. W.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2008-01
Volume
51
Issue
1
Pages
23-32
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1428162896
Cited by
162
References
0
FWCI
21.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Angiographic Surrogate End Points in Drug-Eluting Stent Trials. https://app.cochat.ai/papers/10.1016/j.jacc.2007.07.084
The paper
Pocock, S. J., Lansky, A. J., Mehran, R., Popma, J. J., Fahy, M. P., Na, Y., Dangas, G., Moses, J. W., Pucelikova, T., Kandzari, D. E., Ellis, S. G., Leon, M. B., & Stone, G. W. (2008). Angiographic Surrogate End Points in Drug-Eluting Stent Trials. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2007.07.084

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.