The DOI matches its Crossref record.
Ectopic Expression of the Sodium-Iodide Symporter Enables Imaging of Transplanted Cardiac Stem Cells In Vivo by Single-Photon Emission Computed Tomography or Positron Emission Tomography
Open accessAbstract
Objectives We examined the sodium-iodide symporter (NIS) which promotes in vivo cellular uptake of 99mTc or 124I, as a reporter gene for cell tracking by SPECT or PET imaging. Background Stem cells offer the promise of cardiac repair. Stem cell labeling is a prerequisite to tracking cell fate in vivo. Methods The human NIS cDNA was transduced into rat cardiac-derived stem cells (rCDCs) using lentiviral vectors. Rats were injected intra-myocardially with up to 4 million NIS+-rCDCs immediately following LAD ligation. Dual isotope SPECT (or PET) imaging was performed, using 99mTc (or 124I) for cell detection and 201Tl (or 13NH3) for myocardial delineation. In a subset of animals, high resolution ex vivo SPECT scans of explanted hearts were obtained to confirm that in vivo signals were derived from the cell injection site. Results NIS expression in rCDCs did not affect cell viability and proliferation. NIS activity was verified in isolated transduced cells by measuring 99mTc uptake. NIS+ rCDCs were visualized in vivo as regions of 99mTc or 124I uptake within a perfusion deficit in the SPECT and PET images, respectively. Cells could be visualized by SPECT up to day 6 post-injection. Ex vivo SPECT confirmed that in vivo 99mTc signals were localized to the cell injection sites. Conclusion Ectopic NIS expression allows non invasive in vivo stem cell tracking in the myocardium, using either SPECT or PET. The general approach shows significant promise in tracking the fate of transplanted cells participating in cardiac regeneration, given its ability to observe living cells using clinically-applicable imaging modalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chimenti, I., Smith, R. R., Li, T.-S., Gerstenblith, G., Messina, E., Giacomello, A., & Marbán, E. (2010) · Circulation Research · doi:10.1161/circresaha.109.210682 · Cited by 660
Noninvasive cell-tracking methods
Kircher, M. F., Gambhir, S. S., & Grimm, J. (2011) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2011.141 · Cited by 501
Assessment and Optimization of Cell Engraftment After Transplantation Into the Heart
Terrovitis, J. V., Smith, R. R., & Marbán, E. (2010) · Circulation Research · doi:10.1161/circresaha.109.208991 · Cited by 331
Self-citationThe Na+/I− Symporter (NIS): Mechanism and Medical Impact
Portulano, C., Paroder-Belenitsky, M., & Carrasco, N. (2014) · Endocrine Reviews · doi:10.1210/er.2012-1036 · Cited by 319
The Sodium/Iodide symporter (NIS): Molecular physiology and preclinical and clinical applications
Ravera, S., Reyna-Neyra, A., Ferrandino, G., Amzel, L. M., & Carrasco, N. (2017) · Annual Review of Physiology · doi:10.1146/annurev-physiol-022516-034125 · Cited by 298
Metadata
- Authors
- Terrovitis, J., Kwok, K. F., Lautamäki, R., Engles, J. M., Barth, A. S., Kizana, E., Miake, J., Leppo, M. K., Fox, J., Seidel, J., Pomper, M., Wahl, R. L., Tsui, B., Bengel, F., Marbán, E., & Abraham, M. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2008-11
- Volume
- 52
- Issue
- 20
- Pages
- 1652-1660
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2128756334
- Cited by
- 162
- References
- 0
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ectopic Expression of the Sodium-Iodide Symporter Enables Imaging of Transplanted Cardiac Stem Cells In Vivo by Single-Photon Emission Computed Tomography or Positron Emission Tomography. https://app.cochat.ai/papers/10.1016/j.jacc.2008.06.051
- The paper
- Terrovitis, J., Kwok, K. F., Lautamäki, R., Engles, J. M., Barth, A. S., Kizana, E., Miake, J., Leppo, M. K., Fox, J., Seidel, J., Pomper, M., Wahl, R. L., Tsui, B., Bengel, F., Marbán, E., & Abraham, M. R. (2008). Ectopic Expression of the Sodium-Iodide Symporter Enables Imaging of Transplanted Cardiac Stem Cells In Vivo by Single-Photon Emission Computed Tomography or Positron Emission Tomography. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2008.06.051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.