Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,874

The DOI matches its Crossref record.

Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies

Open access
Tearney, Guillermo J., Regar, Evelyn, Akasaka, Takashi, Adriaenssens, Tom, Barlis, Peter, Bezerra, Hiram G., Bouma, Brett, Bruining, Nico, Cho, Jin-man, Chowdhary, Saqib, Costa, Marco A., de Silva, Ranil, Dijkstra, Jouke, Di Mario, Carlo, Dudeck, Darius, Falk, Erlin, Feldman, Marc D., Fitzgerald, Peter, Garcia, Hector, Gonzalo, Nieves, Granada, Juan F., Guagliumi, Giulio, Holm, Niels R., Honda, Yasuhiro, Ikeno, Fumiaki, Kawasaki, Masanori, Kochman, Janusz, Koltowski, Lukasz, Kubo, Takashi, Kume, Teruyoshi, Kyono, Hiroyuki, Lam, Cheung Chi Simon, Lamouche, Guy, Lee, David P., Leon, Martin B., Maehara, Akiko, Manfrini, Olivia, Mintz, Gary S., Mizuno, Kyiouchi, Morel, Marie-angéle, Nadkarni, Seemantini, Okura, Hiroyuki, Otake, Hiromasa, Pietrasik, Arkadiusz, Prati, Francesco, Räber, Lorenz, Radu, Maria D., Rieber, Johannes, Riga, Maria, Rollins, Andrew, Rosenberg, Mireille, Sirbu, Vasile, Serruys, Patrick W.J.C., Shimada, Kenei, Shinke, Toshiro, Shite, Junya, Siegel, Eliot, Sonada, Shinjo, Suter, Melissa, Takarada, Shigeho, Tanaka, Atsushi, Terashima, Mitsuyasu, Troels, Thim, Uemura, Shiro, Ughi, Giovanni J., van Beusekom, Heleen M.M., van der Steen, Antonius F.W., van Es, Gerrit-Ann, van Soest, Gijs, Virmani, Renu, Waxman, Sergio, Weissman, Neil J., Weisz, Giora·2012·Journal of the American College of Cardiology

Abstract

OBJECTIVES: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. BACKGROUND: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ~10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. METHODS: The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. RESULTS: Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. CONCLUSIONS: This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2011.09.079

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,874

Metadata

Authors
Tearney, G. J., Regar, E., Akasaka, T., Adriaenssens, T., Barlis, P., Bezerra, H. G., Bouma, B., Bruining, N., Cho, J.-M., Chowdhary, S., Costa, M. A., de Silva, R., Dijkstra, J., Di Mario, C., Dudeck, D., Falk, E., Feldman, M. D., Fitzgerald, P., Garcia, H., Gonzalo, N., Granada, J. F., Guagliumi, G., Holm, N. R., Honda, Y., Ikeno, F., Kawasaki, M., Kochman, J., Koltowski, L., Kubo, T., Kume, T., Kyono, H., Lam, C. C. S., Lamouche, G., Lee, D. P., Leon, M. B., Maehara, A., Manfrini, O., Mintz, G. S., Mizuno, K., Morel, M.-A., Nadkarni, S., Okura, H., Otake, H., Pietrasik, A., Prati, F., Räber, L., Radu, M. D., Rieber, J., Riga, M., Rollins, A., Rosenberg, M., Sirbu, V., Serruys, P. W. J. C., Shimada, K., Shinke, T., Shite, J., Siegel, E., Sonada, S., Suter, M., Takarada, S., Tanaka, A., Terashima, M., Troels, T., Uemura, S., Ughi, G. J., van Beusekom, H. M. M., van der Steen, A. F. W., van Es, G.-A., van Soest, G., Virmani, R., Waxman, S., Weissman, N. J., & Weisz, G.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2012-03
Volume
59
Issue
12
Pages
1058-1072
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1956305767
Cited by
1,874
References
0
FWCI
107.93
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies. https://app.cochat.ai/papers/10.1016/j.jacc.2011.09.079
The paper
Tearney, G. J., Regar, E., Akasaka, T., Adriaenssens, T., Barlis, P., Bezerra, H. G., Bouma, B., Bruining, N., Cho, J.-M., Chowdhary, S., Costa, M. A., de Silva, R., Dijkstra, J., Di Mario, C., Dudeck, D., Falk, E., Feldman, M. D., Fitzgerald, P., Garcia, H., . . . Weisz, G. (2012). Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2011.09.079

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.